scholarly journals Determination of 18 Trace Elements in 10 Batches of the Tibetan Medicine Qishiwei Zhenzhu Pills by Direct Inductively Coupled Plasma-Mass Spectrometry

2022 ◽  
Vol 2022 ◽  
pp. 1-10
Author(s):  
Ke Fu ◽  
Yinglian Song ◽  
Dewei Zhang ◽  
Min Xu ◽  
Ruixia Wu ◽  
...  

Qishiwei Zhenzhu pills (QSW) was first recorded in the Tibetan medicine classic Si Bu Yi Dian and has been used to treat “Baimai” disease, stroke, paralysis, hemiplegia, cerebral hemorrhage, and other diseases till today. This prescription contains more than 70 medicines including myrobalan, pearl, agate, opal, bezoar, coral, musk, gold, silver, and a mineral mixture Zuotai. As a result, QSW contains a large amount of mercury, copper, lead, and other trace elements. The aim of this study was to determine the 18 trace elements (lithium, beryllium, scandium, vanadium, chromium, manganese, cobalt, nickel, copper, arsenic, strontium, argentum, cadmium, cesium, barium, lead, aurum, and mercury) in 10 batches of QSW produced by 5 pharmaceutical companies (Ganlu Tibetan Medicine Co., Ltd. has 6 different batches) by direct inductively coupled plasma-mass spectrometry (ICP-MS). ICP-MS is a rapid, sensitive, accurate methodology allowing the determination of 18 elements simultaneously. The results showed that each element had an excellent linear relationship in the corresponding mass concentration range. The results showed that the rank order of the elements in QSW was copper > mercury > lead from high to low, with the mass fraction higher than 6000 μg/kg; the mass fractions of argentum, arsenic, manganese, aurum, strontium, barium, chromium, and nickel were in the range of 33–1034 μg/kg; and the mass fractions of vanadium, cobalt, lithium, beryllium, cadmium, scandium, and cesium were lower than 10 μg/kg. The reproducibility from the same manufacturer (Tibet Ganlu Tibetan Medicine Co., Ltd.) was relatively high; however, the element amounts among 5 manufacturers were different, which could affect the efficacy and toxicity of QSW. All in all, ICP-MS can be used as an effective tool for the analysis of trace elements in QSW and standard quality control needs to be enforced across different manufactures.

1994 ◽  
Vol 77 (4) ◽  
pp. 1004-1023 ◽  
Author(s):  
J E Longbottom ◽  
T D Martin ◽  
K W Edgell ◽  
S E Long ◽  
M R Plantz ◽  
...  

Abstract A joint U.S. Environmental Protection Agency (U.S. EPA)—AOAC interlaboratory method validation study was conducted on U.S. EPA method 200.8, Determination of Trace Elements in Waters and Wastes by Inductively Coupled Plasma–Mass Spectrometry. The purpose of the study was to determine and compare the mean recovery and precision of the inductively coupled plasma–mass spectrometry (ICP–MS) analyses for 20 trace elements in reagent water, drinking water, and groundwater. The formal study was based on Youden’s nonreplicate plan for collaborative tests of analytical methods. The test waters were spiked with the 20 trace elements at 6 concentration levels in the 0.8–200 μg/L range, prepared as 3 Youden pairs. Thirteen collaborators spiked 100 mL aliquots of the test waters, acidified them with 1 mL concentrated HNO3 and 0.5 mL concentrated HCl, reduced the volume to 20 mL by heating in an open beaker at 85°C, refluxed them for 30 min at 95°C, and diluted them to 50 mL. After centrifuging or settling the samples, a 20 mL portion of the supernatant was diluted to 50 mL and analyzed by ICP–MS. Related experiments evaluated the method performance in wastewater and wastewater digestate at a single concentration pair, and an alternative nitric acid digestion procedure. Mean recoveries for reagent water, drinking water, and groundwater were generally 95–105% with between-laboratory relative standard deviations about 4–8%. The method also worked well with wastewaters and digestate, with between-laboratory relative standard deviations averaging 8% and recoveries averaging 100%. Recoveries of silver, however, were low in all matrixes at concentrations over 100 μg/L. The nitric acid digestion procedure was comparable in accuracy and precision to the mixed-acid digestion in U.S. EPA method 200.8. The method was adopted first action by AOAC INTERNATIONAL.


RSC Advances ◽  
2015 ◽  
Vol 5 (89) ◽  
pp. 72500-72507 ◽  
Author(s):  
Philiswa N. Nomngongo ◽  
J. Catherine Ngila

Application of alumina–titania hollow fiber sorptive microextraction coupled to ICP-MS for simultaneous preconcentration of trace elements in liquid fuel samples.


Sign in / Sign up

Export Citation Format

Share Document