Defining the Validity of Skin Self-Examination as a Screening Test for the Detection of Suspicious Pigmented Lesions: A Meta-Analysis of Diagnostic Test Accuracy

Dermatology ◽  
2022 ◽  
pp. 1-9
Author(s):  
Zainab Jiyad ◽  
Elsemieke I. Plasmeijer ◽  
Samantha Keegan ◽  
Venura Samarasinghe ◽  
Adele C. Green ◽  
...  

<b><i>Background:</i></b> Skin self-examination (SSE) is widely promoted for the detection of suspicious pigmented lesions. However, determining screening accuracy is essential to appraising the usefulness of SSE. <b><i>Objectives:</i></b> The aim of this work was to pool estimates from studies of SSE diagnostic accuracy in the detection of suspicious pigmented lesions. <b><i>Methods:</i></b> This study was registered with PROSPERO (CRD42021246356) and conducted in accordance with PRISMA-DTA guidelines. A systematic search of Medline (PubMed) EMBASE, CINAHL, and The Cochrane Library was conducted to identify relevant studies. We included studies that examined the accuracy of SSE, either whole-body or site-specific, for detecting change in individual pigmented lesions or detecting an atypical naevus. A univariate random-effects model, based on logit-transformed data, was used to calculate a summary diagnostic odds ratio (DOR) as well as pooled sensitivity and specificity. Cochran’s <i>Q</i> test and the <i>I</i><sup>2</sup> statistic were calculated to assess heterogeneity. A proportional hazards model was used to calculate the area under the curve (AUC) and plot the summary receiver operator characteristic curve. We used the Quality Assessment of Diagnostic Accuracy Studies-2 tool to grade study quality. <b><i>Results:</i></b> We identified 757 studies, of which 3 met inclusion criteria for quantitative synthesis. The pooled sensitivity and specificity based on 553 included participants was 59 and 82%, respectively. The summary DOR was 5.88 and the AUC was 0.71. There were some concerns regarding risk of bias in all 3 studies. <b><i>Conclusions:</i></b> SSE can detect suspicious pigmented lesions with reasonable sensitivity and relatively high specificity, with the AUC suggesting acceptable discriminatory ability.

2018 ◽  
Vol 17 (5) ◽  
pp. 0-10
Author(s):  
Dahai Xu ◽  
Chang Su ◽  
Liang Sun ◽  
Yuanyuan Gao ◽  
Youjun Li

Introduction and aim. Serum glypican-3 (GPC3) has been explored as a non-invasive biomarker of hepatocellular carcinoma (HCC). However, controversy remains on its diagnostic accuracy. Therefore, we aimed to conduct a systematic review and metaanalysis to evaluate the differential diagnostic accuracy of serum GPC3 between HCC and liver cirrhosis (LC) cases. Material and methods. After the strict filtering and screening of studies from NCBI, PUBMED, Clinical Trials, Cochrane library, Embase, Prospero and Web of Science databases, 11 studies were selected. All studies provided the sensitivity and specificity of GPC3 and the alpha-fetoprotein (AFP) in the HCC and LC diagnosis. The sensitivity and specificity, and the area under the receiver operating characteristic curve (AUC) were determined and compared between GPC3 and AFP, which was set as a positive control. Results. Pooled sensitivity (95% CI) and specificity (95% CI) were 0.55 (0.52-0.58) and 0.58 (0.54-0.61) for GPC3, 0.54 (0.51-0.57) and 0.83 (0.80-0.85) for AFP, and 0.85 (0.81-0.89) and 0.79 (0.73-0.84) for GPC3 + AFP, respectively. The AUCs of GPC3, AFP and GPC3 + AFP were 0.7793, 0.7867 and 0.9366, respectively. GPC3 had a nearly similar sensitivity as AFP, while the specificity and AUC of GPC3 was lower than that of AFP. The combination of GPC3 and AFP yielded a better sensitivity and AUC than GPC3 or AFP. Conclusion. Serum GPC3 is inferior to AFP in the differential diagnosis between HCC and LC. However, the combination of GPC3 and AFP exhibited a much better performance.


2020 ◽  
Vol 132 (4) ◽  
pp. 998-1005 ◽  
Author(s):  
Haihui Jiang ◽  
Yong Cui ◽  
Xiang Liu ◽  
Xiaohui Ren ◽  
Mingxiao Li ◽  
...  

OBJECTIVEThe aim of this study was to investigate the relationship between extent of resection (EOR) and survival in terms of clinical, molecular, and radiological factors in high-grade astrocytoma (HGA).METHODSClinical and radiological data from 585 cases of molecularly defined HGA were reviewed. In each case, the EOR was evaluated twice: once according to contrast-enhanced T1-weighted images (CE-T1WI) and once according to fluid attenuated inversion recovery (FLAIR) images. The ratio of the volume of the region of abnormality in CE-T1WI to that in FLAIR images (VFLAIR/VCE-T1WI) was calculated and a receiver operating characteristic curve was used to determine the optimal cutoff value for that ratio. Univariate and multivariate analyses were performed to identify the prognostic value of each factor.RESULTSBoth the EOR evaluated from CE-T1WI and the EOR evaluated from FLAIR could divide the whole cohort into 4 subgroups with different survival outcomes (p < 0.001). Cases were stratified into 2 subtypes based on VFLAIR/VCE-T1WIwith a cutoff of 10: a proliferation-dominant subtype and a diffusion-dominant subtype. Kaplan-Meier analysis showed a significant survival advantage for the proliferation-dominant subtype (p < 0.0001). The prognostic implication has been further confirmed in the Cox proportional hazards model (HR 1.105, 95% CI 1.078–1.134, p < 0.0001). The survival of patients with proliferation-dominant HGA was significantly prolonged in association with extensive resection of the FLAIR abnormality region beyond contrast-enhancing tumor (p = 0.03), while no survival benefit was observed in association with the extensive resection in the diffusion-dominant subtype (p=0.86).CONCLUSIONSVFLAIR/VCE-T1WIis an important classifier that could divide the HGA into 2 subtypes with distinct invasive features. Patients with proliferation-dominant HGA can benefit from extensive resection of the FLAIR abnormality region, which provides the theoretical basis for a personalized resection strategy.


2021 ◽  
Vol 15 (11) ◽  
pp. e0009869
Author(s):  
Zhuo-Lei Li ◽  
Qi-Bing Luo ◽  
Shan-Shan Xiao ◽  
Ze-Hong Lin ◽  
Ye-Ling Liu ◽  
...  

Purpose Vancomycin-resistant enterococci infection is a worrying worldwide clinical problem. To evaluate the accuracy of GeneXpert vanA/vanB in the diagnosis of VRE, we conducted a systematic review in the study. Methods Experimental data were extracted from publications until May 03 2021 related to the diagnostic accuracy of GeneXpert vanA/vanB for VRE in PubMed, Embase, Web of Science and the Cochrane Library. The accuracy of GeneXpert vanA/vanB for VRE was evaluated using summary receiver to operate characteristic curve, pooled sensitivity, pooled specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. Results 8 publications were divided into 3 groups according to two golden standard references, vanA and vanB group, vanA group, vanB group, including 6 researches, 5 researches and 5 researches, respectively. The pooled sensitivity and specificity of group vanA and vanB were 0.96 (95% CI, 0.93–0.98) and 0.90 (95% CI, 0.88–0.91) respectively. The DOR was 440.77 (95% CI, 37.92–5123.55). The pooled sensitivity and specificity of group vanA were 0.86 (95% CI, 0.81–0.90) and 0.99 (95% CI, 0.99–0.99) respectively, and those of group vanB were 0.85 (95% CI, 0.63–0.97) and 0.82 (95% CI, 0.80–0.83) respectively. Conclusion GeneXpert vanA/vanB can diagnose VRE with high-accuracy and shows greater accuracy in diagnosing vanA.


2019 ◽  
Vol 34 (2) ◽  
pp. 306-314
Author(s):  
Do Hyun Kim ◽  
Youngjun Seo ◽  
Kyung Min Kim ◽  
Seoungmin Lee ◽  
Se Hwan Hwang

Background We evaluated the accuracy of nasal endoscopy in diagnosing chronic rhinosinusitis (CRS) compared with paranasal sinus computed tomography (CT). Methods Two authors independently searched the 5 databases (PubMed, SCOPUS, Embase, the Web of Science, and the Cochrane database) up to March 2019. For all included studies, we calculated correlation coefficients between the endoscopic and CT scores. We extracted data on true-positive and false-positive and true-negative and false-negative results. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool (version 2). Results We included 16 observational or retrospective studies. A high correlation ( r = .8543; 95% confidence interval [CI] [0.7685–0.9401], P < .0001, I2 = 76.58%) between endoscopy and CT in terms of the diagnostic accuracy for CRS was apparent. The odds ratio (Lund–Kennedy endoscopic score ≥1) was 7.915 (95% CI [4.435–14.124]; I2 = 28.361%). The area under the summary receiver operating characteristic curve was 0.765. The sensitivity and specificity were 0.726 (95% CI [0.584–0.834]) and 0.767 (95% CI [0.685–0.849]), respectively. However, high interstudy heterogeneity was evident given the different endoscopic score thresholds used (Lund–Kennedy endoscopic score ≥1 vs 2). In a subgroup analysis of studies using a Lund–Kennedy endoscopic score threshold ≥2, the area under the summary curve was 0.881, and the sensitivity and specificity were 0.874 (95% CI [0.783–0.930]) and 0.793 (95% CI [0.366–0.962]), respectively. Conclusion Nasal endoscopy is a useful diagnostic tool; the Lund–Kennedy score was comparable with that of CT.


2019 ◽  
Vol 92 (1104) ◽  
pp. 20190480 ◽  
Author(s):  
Fan Zhang ◽  
Chen-Lu Liu ◽  
Qian Chen ◽  
Sheng-Chao Shao ◽  
Shuang-Qing Chen

Objective: To evaluate the diagnostic accuracy of multiparametric MRI (mpMRI) for detecting extracapsular extension (ECE) in patients with prostate cancer (PCa). Methods and materials: We searched MEDLINE, PubMed, Embase and the Cochrane library up to December 2018. We included studies that used mpMRI to differentiate ECE from organ-confined PCa with a combination of T2 weighted imaging (T2WI), diffusion-weighted imaging, and dynamic contrast-enhanced MRI. All studies included had pathological diagnosis with radical prostatectomy. Two reviewers independently assessed the methodological quality of included studies by using Quality Assessment of Diagnostic Accuracy Studies 2 tool. We calculated pooled sensitivity, specificity, positive and negative predictive values, diagnostic odds ratios and receiver operating characteristic curve for mpMRI from 2 × 2 tables. Results: A total of 17 studies that comprised 3374 participants were included. The pooled data showed a sensitivity of 0.55 (95% confidence interval 0.43, 0.66]) and specificity of 0.87 (95% confidence interval 0.82, 0.91) for extracapsular extension detection in PCa. Conclusion: First, our meta-analysis shows moderate sensitivity and high specificity for mpMRI to differentiate ECE from organ-confined prostate cancer before surgery. Second, our meta-analysis shows that mpMRI had no significant differences in performance compared with the former meta-analysis with use of T2WI alone or with additional functional MRI. Advances in knowledge: It is the first meta-analysis to evaluate the accuracy of mpMRI in combination of TWI, diffusion-weightedimaging and dynamiccontrast-enhanced-MRI for extracapsular extension detection.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248827
Author(s):  
Lili He ◽  
Yinghua Sun ◽  
Wei Sheng ◽  
Qiong Yao

Several recent studies demonstrated that lung ultrasound could achieve desired diagnostic accuracy for transient tachypnea of the neonate (TTN). However, the diagnostic performance of lung ultrasound for TTN has not been systematically studied to date. This meta-analysis aimed to investigate the performance of lung ultrasound in diagnosing TTN. The relevant literature was searched in PubMed, Medline, the Cochrane Library, and Embase databases without any restriction in terms of language and time until January 31, 2021. Studies that assessed the diagnostic performance of lung ultrasound for TTN were included. Seven studies with 1514 participants were summarized. The lung ultrasound provided more accurate performance for diagnosing TTN with pooled sensitivity and specificity of 0.67 [95% confidence interval (CI) = 0.63–0.71] and 0.97 (95% CI = 0.95–0.98), respectively. A higher summarized area under the summary receiver operating characteristic curve was observed as 0.9906. Lower sensitivity and area under the curve (AUC) of B-lines for TTN were observed as 0.330 (95% CI = 0.27–0.38) and 0.5000, respectively. Lung ultrasound provided highly accurate AUC, sensitivity, and specificity in detecting TTN. Large-scale studies are warranted in the future to confirm these results.


2019 ◽  
Author(s):  
Choon Han Tan ◽  
Bhone Myint Kyaw ◽  
Helen Smith ◽  
Colin S Tan ◽  
Lorainne Tudor Car

BACKGROUND Diabetic retinopathy (DR), a common complication of diabetes mellitus, is the leading cause of impaired vision in adults worldwide. Smartphone ophthalmoscopy involves using a smartphone camera for digital retinal imaging. Utilizing smartphones to detect DR is potentially more affordable, accessible, and easier to use than conventional methods. OBJECTIVE This study aimed to determine the diagnostic accuracy of various smartphone ophthalmoscopy approaches for detecting DR in diabetic patients. METHODS We performed an electronic search on the Medical Literature Analysis and Retrieval System Online (MEDLINE), EMBASE, and Cochrane Library for literature published from January 2000 to November 2018. We included studies involving diabetic patients, which compared the diagnostic accuracy of smartphone ophthalmoscopy for detecting DR to an accurate or commonly employed reference standard, such as indirect ophthalmoscopy, slit-lamp biomicroscopy, and tabletop fundus photography. Two reviewers independently screened studies against the inclusion criteria, extracted data, and assessed the quality of included studies using the Quality Assessment of Diagnostic Accuracy Studies–2 tool, with disagreements resolved via consensus. Sensitivity and specificity were pooled using the random effects model. A summary receiver operating characteristic (SROC) curve was constructed. This review is reported in line with the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies guidelines. RESULTS In all, nine studies involving 1430 participants were included. Most studies were of high quality, except one study with limited applicability because of its reference standard. The pooled sensitivity and specificity for detecting any DR was 87% (95% CI 74%-94%) and 94% (95% CI 81%-98%); mild nonproliferative DR (NPDR) was 39% (95% CI 10%-79%) and 95% (95% CI 91%-98%); moderate NPDR was 71% (95% CI 57%-81%) and 95% (95% CI 88%-98%); severe NPDR was 80% (95% CI 49%-94%) and 97% (95% CI 88%-99%); proliferative DR (PDR) was 92% (95% CI 79%-97%) and 99% (95% CI 96%-99%); diabetic macular edema was 79% (95% CI 63%-89%) and 93% (95% CI 82%-97%); and referral-warranted DR was 91% (95% CI 86%-94%) and 89% (95% CI 56%-98%). The area under SROC curve ranged from 0.879 to 0.979. The diagnostic odds ratio ranged from 11.3 to 1225. CONCLUSIONS We found heterogeneous evidence showing that smartphone ophthalmoscopy performs well in detecting DR. The diagnostic accuracy for PDR was highest. Future studies should standardize reference criteria and classification criteria and evaluate other available forms of smartphone ophthalmoscopy in primary care settings.


BMJ Open ◽  
2019 ◽  
Vol 9 (1) ◽  
pp. e021693 ◽  
Author(s):  
Zengwei Tang ◽  
Yuan Yang ◽  
Xiaolu Wang ◽  
Wenbo Meng ◽  
Xun Li

ObjectiveSerum carbohydrate antigen 19–9 (CA19-9) is a widely used tumour marker for cholangiocarcinoma (CCA). However, it is not a necessarily good CCA marker in terms of diagnostic accuracy. The purpose of this study is to evaluate the diagnostic value ofWisteria floribundaagglutinin-sialylated Mucin1 (WFA-MUC1) and the prognostic role of Mucin1 (MUC1) in human CCA.DesignMeta-analysis.Data sourcesStudies published in PubMed, Web of Science, The Cochrane Library and the China National Knowledge Infrastructure up to 11 October 2017.Eligibility criteriaWe included reports assessing the diagnostic capacity of WFA-MUC1 and the prognostic role of MUC1 in CCA. The receiver operating characteristic curve (ROC) of WFA-MUC1 and/or CA19-9 was described, and the HRs including 95% CI and the corresponding p value for MUC1 can be extracted.Data extraction and synthesisTwo independent researchers extracted data and assessed risk of bias. The diagnostic sensitivity and specificity data of WFA-MUC1 were extracted and analysed as bivariate data. Pooled HRs and its 95% CI for MUC1 were calculated with a random-effects meta-analysis model on overall survival of resectable CCA.ResultsSixteen reports were included in this study. The pooled sensitivity and specificity of WFA-MUC1 were 0.76 (95% CI 0.71 to 0.81) and 0.72 (95% CI 0.59 to 0.83) in serum, 0.85 (95% CI 0.81 to 0.89) and 0.72 (95% CI 0.64 to 0.80) in bile and 0.72 (95% CI 0.50 to 0.87) and 0.85 (95% CI 0.70 to 0.93) in tissue, respectively. The summary ROC (SROC) were 0.77 (95% CI 0.73 to 0.81) in serum, 0.88 (95% CI 0.85 to 0.90) in bile and 0.86 (95% CI 0.83 to 0.89) in tissue, respectively. Furthermore, the pooled sensitivity and specificity and the SROC of CA19-9 in serum were 0.67 (95% CI 0.61 to 0.72), 0.86 (95% CI 0.75 to 0.93) and 0.75 (95% CI 0.71 to 0.79), respectively. The pooled HRs for MUC1 was 2.20 (95% CI 1.57 to 3.01) in CCA and 4.17 (95% CI 1.71 to 10.17) in mass-forming intrahepatic CCA.ConclusionsCompared with CA19-9, WFA-MUC1 was shown to possess stronger diagnostic capability. MUC1 could serve as a prognosis factor for poor outcomes of CCA, particularly, mass-forming intrahepatic CCA.


Diagnostics ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 293
Author(s):  
Soo Hee Ko ◽  
Jung-Soo Pyo ◽  
Byoung Kwan Son ◽  
Hyo Young Lee ◽  
Il Whan Oh ◽  
...  

The present study aimed to compare the diagnostic accuracy between conventional smear (CS) and liquid-based preparation (LBP) in endoscopic ultrasonography-fine needle aspiration cytology (EUS-FNAC) of pancreatic lesions. Using 31 eligible studies, the diagnostic accuracy of cytologic examination in CS and LBP was evaluated through a conventional meta-analysis and diagnostic test accuracy review. Overall concordance rates were 82.8% (95% confidence interval [CI], 79.8–85.5%) and 94.0% (95% CI, 84.4–97.8%) in CS and LBP, respectively. CS with rapid on-site evaluation (ROSE) showed a higher concordance rate than CS without ROSE. In CS, the pooled sensitivity and specificity were 89.8% (95% CI, 85.2–93.1%) and 95.0% (95% CI, 90.0–97.6%), respectively. The diagnostic odds ratio (OR) and area under curve (AUC) of the summary receiver operating characteristic (SROC) curve were 90.32 (95% CI, 43.85–147.11) and 0.945, respectively. In LBP, the pooled sensitivity and specificity were 80.9% (95% CI, 69.7–88.7%) and 99.9% (95% CI, 1.5–100.0%), respectively. The diagnostic OR and AUC of the SROC curve were 57.21 (95% CI, 23.61–138.64) and 0.939, respectively. Higher concordance rates were found in CS with ROSE and LBP in EUS-FNAC of pancreatic lesions. Regardless of the cytologic preparation method, EUS-FNAC is a useful and accurate diagnostic tool for pancreatic lesions.


2020 ◽  
Vol 2020 ◽  
pp. 1-14
Author(s):  
Zhizhuo Li ◽  
Qingyu Zhang ◽  
Lijun Shi ◽  
Fuqiang Gao ◽  
Wei Sun ◽  
...  

Periprosthetic joint infection (PJI) is a devastating complication after arthroplasty. Prompt establishment of an infection diagnosis is critical but can be very challenging at present. In order to evaluate the diagnostic accuracy of alpha-defensin or leukocyte esterase for PJI, we performed systematic research in PubMed, Embase, and Cochrane Library to retrieve relevant studies. Data extraction and quality assessment were performed by two reviewers independently. A total of thirty-one eligible studies were finally included in the quantitative analysis. The pooled sensitivity and specificity of alpha-defensin (21 studies) for the diagnosis of PJI were 0.89 (95% confidence interval (CI), 0.83 to 0.93) and 0.96 (95% CI, 0.95 to 0.97), respectively. The value of the pooled diagnostic odds ratios (DOR) of alpha-defensin for PJI was 209.14 (95% CI, 97.31 to 449.50), and the area under the curve (AUC) was 0.98 (95% CI, 0.96 to 0.99). The pooled sensitivity and specificity of leukocyte esterase (17 studies) for the diagnosis of PJI were 0.90 (95% CI, 0.84 to 0.95) and 0.96 (95% CI, 0.93 to 0.97), respectively. The value of the DOR of leukocyte esterase for PJI was 203.23 (95% CI, 96.14 to 429.61), and the AUC was 0.98 (95% CI, 0.96 to 0.99). Based on the results of our meta-analysis, we can conclude that alpha-defensin and leukocyte esterase are valuable synovial fluid markers for identifying PJI with comparable high diagnostic accuracy.


Sign in / Sign up

Export Citation Format

Share Document