scholarly journals A hybrid algorithm for voltage stability enhancement of distribution systems

Author(s):  
Hazim Sadeq Mohsin Al-Wazni ◽  
Shatha Suhbat Abdulla Al-Kubragyi

This paper presents a hybrid algorithm by applying a hybrid firefly and particle swarm optimization algorithm (HFPSO) to determine the optimal sizing of distributed generation (DG) and distribution static compensator (D-STATCOM) device. A multi-objective function is employed to enhance the voltage stability, voltage profile, and minimize the total power loss of the radial distribution system (RDS). Firstly, the voltage stability index (VSI) is applied to locate the optimal location of DG and D-STATCOM respectively. Secondly, to overcome the sup-optimal operation of existing algorithms, the HFPSO algorithm is utilized to determine the optimal size of both DG and D-STATCOM. Verification of the proposed algorithm has achieved on the standard IEEE 33-bus and Iraqi 65-bus radial distribution systems through simulation using MATLAB. Comprehensive simulation results of four different cases show that the proposed HFPSO demonstrates significant improvements over other existing algorithms in supporting voltage stability and loss reduction in distribution networks. Furthermore, comparisons have achieved to demonstrate the superiority of HFPSO algorithms over other techniques due to its ability to determine the global optimum solution by easy way and speed converge feature.

Author(s):  
Ihsan Salman ◽  
Khalid Mohammed ◽  
Khalid Shaker ◽  
Hothefa Shaker

The environment friendly designing and running of electricity distribution structures are becoming vaster with the conjunction of renewable electricity options into power distribution systems. This study presents Moth Flame Optimization (MFO) approach to minimize total losses kW and energy cost and maximize net savings with solving the voltage deviation problem through optimal site and size of capacitor banks in electrical radial distribution networks. Two various load profiles are utilized to take a look at the modified algorithm on IEEE 123-, and 13-bus check networks. The OpenDSS software is utilized to resolve the power flowing via MATLAB programming interface. The results obtained are compared with IEEE normal state and other two heuristic approaches in same study, namely, imperialist competitive algorithm and particle swarm optimization. The proposed algorithm is more effective to minimise the total power losses and total cost and maximise net savings and to enhance the voltage profile for various distribution systems.


Author(s):  
Sayed Mir Shah Danish ◽  
Mikaeel Ahmadi ◽  
Atsushi Yona ◽  
Tomonobu Senjyu ◽  
Narayanan Krishna ◽  
...  

AbstractThe optimal size and location of the compensator in the distribution system play a significant role in minimizing the energy loss and the cost of reactive power compensation. This article introduces an efficient heuristic-based approach to assign static shunt capacitors along radial distribution networks using multi-objective optimization method. A new objective function different from literature is adapted to enhance the overall system voltage stability index, minimize power loss, and to achieve maximum net yearly savings. However, the capacitor sizes are assumed as discrete known variables, which are to be placed on the buses such that it reduces the losses of the distribution system to a minimum. Load sensitive factor (LSF) has been used to predict the most effective buses as the best place for installing compensator devices. IEEE 34-bus and 118-bus test distribution systems are utilized to validate and demonstrate the applicability of the proposed method. The simulation results obtained are compared with previous methods reported in the literature and found to be encouraging.


2019 ◽  
Vol 2019 ◽  
pp. 1-20 ◽  
Author(s):  
Khalid Mohammed Saffer Alzaidi ◽  
Oguz Bayat ◽  
Osman N. Uçan

Distributed generators (DGs) are currently extensively used to reduce power losses and voltage deviations in distribution networks. The optimal location and size of DGs achieve the best results. This study presents a novel hybridization of new metaheuristic optimizations in the last two years, namely, salp swarm algorithm (SSA) and whale optimization algorithm (WOA), for optimal placement and size of multi-DG units in radial distribution systems to minimize total real power losses (kW) and solve voltage deviation. This hybrid algorithm is implemented on IEEE 13- and 123-node radial distribution test systems. The OpenDSS engine is used to solve the power flow to find the power system parameters, such power losses, and the voltage profile through the MATLAB coding interface. Results describe the effectiveness of the proposed hybrid WOA-SSA algorithm compared with those of the IEEE standard case (without DG), repeated load flow method, and WOA and SSA algorithms applied independently. The analysis results via the proposed algorithm are more effective for reducing total active power losses and enhancing the voltage profile for various distribution networks and multi-DG units.


2021 ◽  
Vol 13 (18) ◽  
pp. 10224
Author(s):  
Sasan Azad ◽  
Mohammad Mehdi Amiri ◽  
Morteza Nazari Heris ◽  
Ali Mosallanejad ◽  
Mohammad Taghi Ameli

Considering the strong influence of distributed generation (DG) in electric distribution systems and its impact on network voltage losses and stability, a new challenge has appeared for such systems. In this study, a novel analytical algorithm is proposed to distinguish the optimal location and size of DGs in radial distribution networks based on a new combined index (CI) to reduce active power losses and improve system voltage profiles. To obtain the CI, active power losses and voltage stability indexes were used in the proposed approach. The CI index with sensitivity analysis was effective in decreasing power losses and improving voltage stability. Optimal DG size was determined based on a search algorithm to reduce active power losses. The considered scheme was examined through IEEE 12-bus and 33-bus radial distribution test systems (RDTS), and the obtained results were compared and validated in comparison with other available methods. The results and analysis verified the effectiveness of the proposed algorithm in reducing power losses and improving the distribution system voltage profiles by determining the appropriate location and optimal DG size. In IEEE 12 and 33 bus networks, the minimum voltage increased from 0.9434 p.u and 0.9039 p.u to 0.9907 p.u and 0.9402 p.u, respectively. Additionally, the annual cost of energy losses decreased by 78.23% and 64.37%, respectively.


2020 ◽  
Vol 35 ◽  
pp. 94-101 ◽  
Author(s):  
Omrane Bouketir ◽  
Haddi Sebaa ◽  
Tarek Bouktir

Installation of distributed generations (DGs) could be an effective solution to the problem of shortage of the electric energy especially in populated areas. Installation of DG in non-suitable places can result in more energy losses and voltage instability which leads to higher operating cost. DGs should be placed optimally in the network to get maximum efficiency of the system. This paper presents a new method to solve the optimal sizing and placement of DGs with the aim of minimizing real power loss and improving voltage profile in a distribution system. A power flow technique based on Backward/Forward (BW/FW) sweep is used to calculate the system losses through different branches. Particle Swarm Optimization algorithm is used to find out the optimal size and to identify the DG units placement in a radial distribution system simultaneously. Different scenarios of DG capacity are considered. The constraints of voltage and current through branches are investigated. The method is tested on 33-bus and 69-bus radial distribution systems to demonstrate the performance and the effectiveness of the proposed method. The results obtained are discussed and analyzed where they proved the usefulness of the applied algorithm.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Varaprasad Janamala

AbstractA new meta-heuristic Pathfinder Algorithm (PFA) is adopted in this paper for optimal allocation and simultaneous integration of a solar photovoltaic system among multi-laterals, called interline-photovoltaic (I-PV) system. At first, the performance of PFA is evaluated by solving the optimal allocation of distribution generation problem in IEEE 33- and 69-bus systems for loss minimization. The obtained results show that the performance of proposed PFA is superior to PSO, TLBO, CSA, and GOA and other approaches cited in literature. The comparison of different performance measures of 50 independent trail runs predominantly shows the effectiveness of PFA and its efficiency for global optima. Subsequently, PFA is implemented for determining the optimal I-PV configuration considering the resilience without compromising the various operational and radiality constraints. Different case studies are simulated and the impact of the I-PV system is analyzed in terms of voltage profile and voltage stability. The proposed optimal I-PV configuration resulted in loss reduction of 77.87% and 98.33% in IEEE 33- and 69-bus systems, respectively. Further, the reduced average voltage deviation index and increased voltage stability index result in an improved voltage profile and enhanced voltage stability margin in radial distribution systems and its suitability for practical applications.


Author(s):  
Mahesh Kumar ◽  
Perumal Nallagownden ◽  
Irraivan Elamvazuthi ◽  
Pandian Vasant ◽  
Luqman Hakim Rahman

In the distribution system, distributed generation (DG) are getting more important because of the electricity demands, fossil fuel depletion and environment concerns. The placement and sizing of DGs have greatly impact on the voltage stability and losses in the distribution network. In this chapter, a particle swarm optimization (PSO) algorithm has been proposed for optimal placement and sizing of DG to improve voltage stability index in the radial distribution system. The two i.e. active power and combination of active and reactive power types of DGs are proposed to realize the effect of DG integration. A specific analysis has been applied on IEEE 33 bus system radial distribution networks using MATLAB 2015a software.


SCITECH Nepal ◽  
2019 ◽  
Vol 14 (1) ◽  
pp. 1-7
Author(s):  
Avinash Khatri KC ◽  
Tika Ram Regmi

An electric distribution system plays an important role in achieving satisfactory power supply. The quality of power is measured by voltage stability and profile of voltage. The voltage profile is affected by the losses in distribution system. As the load is mostly inductive on the distribution system and requires large reactive power, most of the power quality problems can be resolved with requisite control of reactive power. Capacitors are often installed in distribution system for reactive power compensation. This paper presents two stage procedures to identify the location and size of capacitor bank. In the first stage, the load flow is carried out to find the losses of the system using sweep algorithm. In the next stage, different size of capacitors are initialized and placed in each possible candidate bus and again load flow for the system is carried out. The objective function of the cost incorporating capacitor cost and loss cost is formulated constrained with voltage limits. The capacitor with the minimum cost is selected as the optimized solution. The proposed procedure is applied to different standard test systems as 12-bus radial distribution systems. In addition, the proposed procedure is applied on a real distribution system, a section of Sallaghari Feeder of Thimi substation. The voltage drops and power loss before and after installing the capacitor were compared for the system under test in this work. The result showed better voltage profiles and power losses of the distribution system can be improved by using the proposed method and it can be a benefit to the distribution networks.


Author(s):  
S. Bhongade ◽  
Sachin Arya

The work presented in this paper is carried out with the objective of identifying the optimal location and size (Kvar ratings) of shunt capacitors to be placed in radial distribution system, to have overall economy considering the saving due to energy loss minimization. To achieve this objective, a two stage methodology is adopted in this paper. In the first stage, the base case load flow of uncompensated distribution system is carried out. On the basis of base case load flow solution, Nominal voltage magnitudes and Loss Sensitivity Factors are calculated and the weak buses are selected for capacitor placement.In the second stage, Particle Swarm Optimization (PSO) algorithm is used to identify the size of the capacitors to be placed at the selected buses for minimizing the power loss. The developed algorithm is tested for 10-bus, 34-bus and 85-bus Radial Distribution Systems. The results show that there has been an enhancement in voltage profile and reduction in power loss thus resulting in much annual saving.


Sign in / Sign up

Export Citation Format

Share Document