scholarly journals Evaluation of sensitivity and spesitivity as COVID–19 screening method

2021 ◽  
Vol 10 (4) ◽  
pp. 758
Author(s):  
Atikah Nurhesti ◽  
Solikhah Solikhah ◽  
Siti Nur Djannah

Coronavirus disease 2019 (COVID-19) is caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Antibody rapid test is one of the COVID-19 screening tests that can be used in the community. The accuracy of the rapid antibody methods needs to be appropriately assessed, it is necessary to carry out a diagnostic accuracy study using a pairwise sensitivity and specificity analysis. This research aimed to assess the sensitivity and specificity of COVID-19 rapid tests, also assesses positive predictive value (PPV) and negative predictive value (NPV) of the rapid antibody test as a method of screening for COVID-19 in Sleman Regency, Indonesia. In total, 118 respondents who have contact with COVID-19 patients and have symptoms were enrolled in this study. The study was conducted on 118 patients who had been in contact with confirmed COVID-19 118 patients who met the close contact criteria were conducted a rapid antibody test. 64.41% patients were reactive. Real-time polymerase chain reaction (RT PCR) as a gold standard was also carried out for all patients and 63.56% affirmed positive for COVID-19. The sensitivity value was 97.33%, and the specificity value was 93.02%, while the positive predictive value (NPP) was 96.05%, and the negative predictive value (NPN) was 95.24%. These results meet the minimum recommendations for the screening method.

BMC Cancer ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Blanca Murillo-Ortiz ◽  
Abraham Hernández-Ramírez ◽  
Talia Rivera-Villanueva ◽  
David Suárez-García ◽  
Mario Murguía-Pérez ◽  
...  

Abstract Background Some evidence has shown that malignant breast tumours have lower electrical impedance than surrounding normal tissues. Electrical impedance could be used as an indicator for breast cancer detection. The purpose of our study was to analyse the sensitivity and specificity of electrical impedance mammography (EIM) and its implementation for the differential diagnosis of pathological lesions of the breast, either alone or in combination with mammography/ultrasound, in 1200 women between 25 and 70 years old. Methods This study is a prospective, cross-sectional epidemiological observational study of serial screening. The women were invited to participate and signed a consent letter. Impedance imaging of the mammary gland was evaluated with the computerized mammography equipment of MEIK electroimpedance v.5.6. (0.5 mA, 50 kHz), developed and manufactured by PKF SIM-Technika®. The successful identification of breast cancer along with the sensitivity, specificity, and positive and negative predictive values of EIM were determined as follows: % sensitivity; % specificity; % positive predictive value (PPV); and % negative predictive value (NPV). Results EIM had a sensitivity of 85% and a specificity of 96%; the positive predictive value was 12%, and the negative predictive value was 99%. Seven cases were biopsy confirmed cancers. Significant correlations between the electrical conductivity index and body mass index (BMI) (p = 0.04) and patient age were observed (p = 0.01). We also observed that the average conductivity distribution increased according to age group (p = 0.001). We used the chi-squared test to assess the interactions between percent density and BMI (normal < 25 kg/m2 (n = 310), overweight 25–29.9 kg/m2 (n = 418) and obese ≥30 (n = 437)) (p <  0.05). The patients with a diagnosis of mammary carcinoma had a BMI of 35.51 kg/m2. Conclusions Our results demonstrate that the use of monofrequency electrical impedance mammography (EIM) in the detection of breast cancer had a sensitivity and specificity of 85 and 96%, respectively. These findings may support future research in the early detection of breast cancer. EIM is a non-radiation method that may also be used as a screening method for young women with dense breasts and a high risk of developing breast cancer.


2020 ◽  
Vol 18 (2) ◽  
Author(s):  
Wan Nurliyana Wan Ramli

Introduction: Melioidosis is endemic in Malaysia and an important cause of sepsis. Current gold standard for diagnosis is by culture method,but its long procedure will delay the treatment leading to hospital-related mortality.Thus,a good rapid test is needed to reduce its mortality burden. Recently, Active Melioidosis Detect (AMD) have been shown to be useful. Objectives: (1)To measure the sensitivity and specificity of AMD. (2)To study the sensitivity and specificity of early morning urine AMD compared to spot urine AMD. Materials and method: A prospective crosssectional study of clinically suspected melioidosis patients in HTAA and HSNZ from April until December 2018. Blood and urine samples were tested with AMD. Test results were analysed for sensitivity, specificity,positive predictive value and negative predictive value. Results: A total of 89 patients were included in this study.The mean age is 52 years old, and 56.3% were male gender.64% of patients have diabetes mellitus.11 patients have positive blood culture for Bukholderia pseudomallei, 4 of them were tested positive for AMD.3 of them presented with septic shock (3.4%), however none died.The sensitivity of the AMD was 36.4% ([95% CI 12.4 to 68.4]) and the specificity was 66.7% ( [95% CI 46.0 to 82.8]) in all samples, with positive predictive value of 30.7% and negative predictive value of 72%.Blood samples have lower sensitivity of 9.1% ([95% CI 4.8 to 42.9]) with high specificity of 100% ([95% CI 84.5 to 100]). Urine spot samples have higher sensitivity compared to serum and morning urine, with 36.4% ([95%CI 12.4 to 68.4]) and specificity of 88.9% ([95% CI 69.7 to 97.1]). Conclusion: From this pilot study, this test requires further evaluation before incorporating as point of care assay.


Author(s):  
Royyuru Suchitra ◽  
Kaustubh Burde ◽  
Nilima G. ◽  
P. L. S. Sahithi

Background: Ovarian cancer possesses a challenge to screening tests due to its anatomical location, poor natural history, lack of specific lesion, symptoms and signs and low prevalence. Authors shall be considering RMI 2 and RMI 4 (forms of RMI) and comparing them with histopathology report to derive the sensitivity, specificity and other parameters of these tests.Methods: A prospective   study was conducted from September 2016- September 2017 at Mazumdar Shaw Hospital, Narayana Hrudayalaya, Bangalore.73 patients met the inclusion criteria. RMI 2   and RMI4 were calculated for all the patients and these scores were compared to the final histopathology reports.Results: In present study of 73 patients RMI2 showed a sensitivity of 86.6%, specificity of 86.5 %, Positive predictive value of 81.25% and negative predictive value of 90.24 %. Whereas RMI4 showed a sensitivity of 86.6%, specificity of 86.5 %, Positive predictive value of 83.87 and negative predictive value of 90.48 %. These results are comparable to other studies conducted.  The risk of malignancy index 2 and 4 are also almost comparable with each other and so either can be used for determining the risk of malignancy in patients with adnexal masses. These results were derived in an Indian population across all age groups showing that authors can apply this low-cost method even in resource limited settings.Conclusions: Authors found that Risk of malignancy index is a simple and affordable method to determine the likelihood of a patient having adnexal mass to be malignant. This can thus help save the resources and make the services available at grass root level.


2015 ◽  
Vol 52 (3) ◽  
pp. 195-199 ◽  
Author(s):  
Naser HONAR ◽  
Bita GERAMIZADEH ◽  
Seyed-Mohsen DEHGHANI ◽  
Gholamreza KALVANDI ◽  
Iraj SHAHRAMIAN ◽  
...  

BackgroundSpontaneous bacterial peritonitis is defined as an ascetic fluid infection without an evident intra-abdominal surgically treatable source. Spontaneous bacterial peritonitis is one of the severe complications in patients with cirrhosis and ascites. Without early antibiotic treatment, this complication is associated with high mortality rate; therefore, early diagnosis and treatment of spontaneous bacterial peritonitis is necessary for survival. Leukocyte esterase reagent can rapidly diagnose the spontaneous bacterial peritonitis.ObjectiveThis study aimed to find out the diagnostic accuracy of leukocyte esterase dipstick test for the diagnosis of spontaneous bacterial peritonitis.MethodsA single centered hospital-based cross-sectional study was conducted during July 2013 to August 2014 on children with cirrhotic liver disease and ascites who were admitted in the Department of Pediatric Gastroenterology in Nemazee Hospital affiliated to Shiraz University of Medical Sciences (Iran). All patients underwent abdominal paracentesis, and the ascitic fluid was processed for cell count, leukocyte esterase reagent strip test (Combiscreen SL10) and culture. Spontaneous bacterial peritonitis was defined as having a polymorphonuclear count (PMN ≥250/m3) in ascitic fluid. Sensitivity, specificity, positive predictive value and negative predictive value of leukocyte esterase test were calculated according to the formula.ResultsTotally, 150 ascitic fluid sample of cirrhotic male patients (53.2%) and their mean age (4.33±1.88 years) were analyzed. Biliary atresia (n=44, 29.4%) and idiopathic neonatal hepatitis (n=29, 19.3%) were the most frequent etiology of cirrhosis. Also, abdominal pain (68.6%) and distension (64%) were the most common presenting complaint. Of all cases, 41patients (27.35%) were diagnosed to have spontaneous bacterial peritonitis (PMN ≥250/mm3). Sensitivity and specificity of leukocyte esterase reagent test according to PMNs ≥250mm3 were 87.80% and 91.74%, also on ascitic fluid culture results were 88.23% and 77.44%. Positive predictive value and negative predictive value of this test in PMNs ≥250mm3 were 80% and 95.23% and in cases with positive culture 33.33% and 98.09% were obtained, respectively. Efficiency of leukocyte esterase reagent test in diagnosing spontaneous bacterial peritonitis, according to PMNs ≥250mm3 and culture results were 90.66% and 78.66%.ConclusionThe leukocyte esterase strip test may be used as rapid test for diagnosis of spontaneous bacterial peritonitis due to its high diagnostic validity.


2015 ◽  
Vol 51 (5) ◽  
pp. 306-310 ◽  
Author(s):  
Lauren Cunningham ◽  
Audrey Cook ◽  
Andrew Hanzlicek ◽  
Kenneth Harkin ◽  
Joseph Wheat ◽  
...  

The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131–1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4689-4689
Author(s):  
Sriman Swarup ◽  
Somedeb Ball ◽  
Nimesh Adhikari ◽  
Anita Sultan ◽  
Khatrina Swarup ◽  
...  

Introduction: Heparin induced thrombocytopenia (HIT) is a severe prothrombotic condition, usually triggered by exposure to heparin products. It is characterized by platelet activation induced by the formation of antibodies to the platelet factor 4 (PF4)/ heparin polyanion complexes. Diagnostic algorithm includes clinical scoring (4T score) alongside serological test for detection of these antibodies (HIT-Ab), while serotonin release assay (SRA) remains the gold- standard for confirmation. The automated latex immunoturbidometric assay (LIA) has recently been FDA approved as a screening tool for HIT and is a potential alternative to the conventional particle immunofiltration assay (PIFA) for time-sensitive detection of HIT-Ab to guide treatment considerations. We recently introduced LIA in our institution. In this study, we present our experience with LIA in comparison to PIFA in the diagnosis of HIT. Methods: We retrospectively reviewed the charts of all the patients on whom a PIFA was ordered between March 2017 and March 2018 in our hospital. We collected information on the results of the PIFA and SRA (if available). We replaced PIFA with LIA for HIT screening. Then, we introduced a structured protocol for diagnosis of HIT in our institution by incorporating 4T scoring alongside LIA order in the electronic medical record (EMR), in December 2018. We reviewed the EMR of all the patients on whom HIT-Ab test (LIA) was ordered between January and June of 2019, and collected similar information as before. All the data were compiled in a single master excel sheet for calculation of performance characteristics (sensitivity, specificity, positive and negative predictive values) for both PIFA and LIA. A patient was considered to have the diagnosis of HIT if the result of SRA was available and positive. Results: In the first phase, a total of 31 orders for SRA was noted against 170 PIFA orders. Five patients had a positive SRA, of whom two were PIFA negative. Half the patients with a negative SRA result were positive for PIFA. Hence, the sensitivity and specificity of PIFA test for our study population were noted to be 60% and 50%, respectively. PIFA had a positive predictive value (PPV) of mere 18.75% for the diagnosis of HIT, whereas the negative predictive value (NPV) was found to be 86.66%. Introduction of structured protocol for HIT diagnosis substantially reduced the number of inappropriate SRA orders in the second phase. On review of data for six months with the new HIT-Ab test LIA, SRA was ordered in only eight patients, to go with 69 orders for the LIA. The result of LIA was positive in all three patients with a positive SRA, whereas it was false positive in four instances. Only one patient was negative for both LIA and SRA during this period. LIA was found to be 100% sensitive and 20% specific for the diagnosis of HIT in our sample. PPV and NPV for LIA were 42.85% and 100%, respectively. Conclusion: The sensitivity and specificity of LIA were found to be 100% and 20%, respectively, in our study population, which is different from the earlier report (Warkentin et al. 2017). The small sample size is a limitation of our study. Higher PPV and NPV for LIA, with its quick turnaround time, make it a useful alternative for the time-sensitive determination of post-test probability for HIT in patients. [HIT- Ab- Heparin Induced Thrombocytopenia Antibody, PIFA- Particle Immunofiltration Assay, LIA- Latex Immunoturbidometric Assay, SRA- Serotonin Release Assay, +ve- Positive, -ve - Negative, PPV- Positive Predictive Value, NPV- Negative Predictive Value] Disclosures No relevant conflicts of interest to declare.


Author(s):  
Jesha Mundodan ◽  
Samina Hasnain ◽  
Hayat Khogali ◽  
Soha Shawqi Al Bayat ◽  
Dina Ali ◽  
...  

Background: In response to the growing coronavirus disease 2019 (COVID-19) pandemic and the shortage of laboratory based molecular testing capacity and reagents, multiple diagnostic test manufacturers have developed rapid and easy to use devices to facilitate testing outside laboratory settings. These kits are either based on detection of proteins from SARS-CoV-2 virus or detection of antigen or human antibodies generated in response to the infection. However, it is important to understand their performance characteristics and they must be validated in the local population setting.Design and Methods: The objective is to assess the validity of the rapid test for IgG and IgM immunoglobulins compared to the current gold standard reverse transcription polymerase chain reaction (RT-PCR) test. A total of 16951 asymptomatic individuals were tested by the Ministry of Public Health track-and-trace team using both rapid immunodiagnostic test and RT-PCR as part of screening across various random settings with potential risk of community interaction prior to gradual lifting of restrictions in Qatar.  Rapid test was considered to be posiive if both IgG and IgM are positive, while only IgG/IgM positive was considered as rapid test negative. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated.Results: The sensitivity of rapid test kit was found to be 0.9%, whereas the specificity was found to be 97.8%. the PPV was found to be 0.3% whereas the NPV was found to be 99.4%.Conclusion: Based on the outcome and results of the study, it appears that the sensitivity and PPV of the rapid antibody test are low. As such, this test is not recommended for use to assist in taking clinic-based decisions or decisions related to quarantine/isolation.


Author(s):  
Dr. Chaturbhuj Prasad Swarnkar ◽  
Dr. Shiv Raj Meena

Background- Rotator cuff tears are one of the most common causes of shoulder pain for which patients seek treatment. As in our daily work, the shoulder joint is the most frequently used, there is higher chance of having shoulder joint injury. The aim of the study is to compare the efficacy of MRI in diagnosing shoulder pathologies in comparison to arthroscopy, considering arthroscopy as the gold standard. Methods- 30 Patient with suspected rotator cuff injury patients, between 18-80 years of age was included in the study. MRI of the shoulder joint was done followed by shoulder arthroscopy. The data collected was analysed for the significant correlation between MRI of shoulder and arthroscopic findings by kappa statistics. Results- The accuracy of MRI in diagnosis of rotator cuff partial tears, was 90%, while sensitivity and specificity was 100.00%, 78.57% and positive predictive value was 84.21% and negative predictive value was 100.00% and accuracy of MRI in diagnosis of rotator cuff full tears, was 86.67%, while sensitivity and specificity was 63.64%, 100.00%) and positive predictive value was 100.00% and negative predictive value was 82.61% in our study. Conclusion- Our study demonstrates a high sensitivity and specificity for the MRI diagnosis of both partial and full thickness rotator cuff tears and good correlation with arthroscopic findings. Keywords: Rotator cuff, Shoulder pain, Arthroscopy, MRI.


Neurosurgery ◽  
2012 ◽  
Vol 70 (5) ◽  
pp. 1114-1124 ◽  
Author(s):  
Robert T. Wicks ◽  
Gustavo Pradilla ◽  
Shaan M. Raza ◽  
Uri Hadelsberg ◽  
Alexander L. Coon ◽  
...  

Abstract BACKGROUND: Somatosensory evoked potential (SSEP) monitoring is used during intracranial aneurysm surgery to track the effects of anesthesia, surgical manipulation, and temporary clipping. OBJECTIVE: To present the outcomes of 663 consecutive patients (691 cases) treated surgically for intracranial aneurysms who underwent intraoperative SSEP monitoring and to analyze the sensitivity and specificity of significant SSEP changes in predicting postoperative stroke. METHODS: Of 691 surgeries analyzed, 403 (391 anterior circulation, 12 posterior circulation) were unruptured aneurysms and 288 (277 anterior, 11 posterior) were ruptured. Postoperatively, symptomatic patients underwent computed tomography imaging. Positive predictive value, negative predictive value, sensitivity, and specificity were calculated with a Fisher exact test (2-tailed P value). RESULTS: Changes in SSEP occurred in 45 of 691 cases (6.5%): 16 of 403 (4.0%) in unruptured aneurysms and 29 of 288 (10%) in ruptured aneurysms. In unruptured aneurysms, reversible SSEP changes were associated with a 20% stroke rate, but irreversible changes were associated with an 80% stroke rate. In ruptured aneurysms, however, reversible changes were associated with a 12% stroke rate, and irreversible changes were associated with a 42% stroke rate. The overall accuracy of SSEP changes in predicting postoperative stroke was as follows: positive predictive value, 30%; negative predictive value, 94%; sensitivity, 25%; and specificity, 95%. CONCLUSION: Intraoperative SSEP changes are more reliable in unruptured aneurysm cases than in ruptured cases. Whereas irreversible changes in unruptured cases were associated with an 80% stroke rate, such changes in ruptured cases did not have any adverse ischemic sequelae in 58% of patients. This information is helpful during the intraoperative assessment of reported SSEP changes.