The equivalent method of double V-wing honeycombs on the in-plane dynamic impact

2021 ◽  
pp. 073168442199086
Author(s):  
Yunfei Qu ◽  
Dian Wang ◽  
Hongye Zhang

The double V-wing honeycomb can be applied in many fields because of its lower mass and higher performance. In this study, the volume, in-plane elastic modulus and unit cell area of the double V-wing honeycomb were analytically derived, which became parts of the theoretical basis of the novel equivalent method. Based on mass, plateau load, in-plane elastic modulus, compression strain and energy absorption of the double V-wing honeycomb, a novel equivalent method mapping relationship between the thickness–width ratio and the basic parameters was established. The various size factor of the equivalent honeycomb model was denoted as n and constructed by the explicit finite element analysis method. The mechanical properties and energy absorption performance for equivalent honeycombs were investigated and compared with hexagonal honeycombs under dynamic impact. Numerical results showed a well coincidence for each honeycomb under dynamic impact before 0.009 s. Honeycombs with the same thickness–width ratio had similar mechanical properties and energy absorption characteristics. The equivalent method was verified by theoretical analysis, finite element analysis and experimental testing. Equivalent honeycombs exceeded the initial honeycomb in performance efficiency. Improvement of performance and weight loss reached 173.9% and 13.3% to the initial honeycomb. The double V-wing honeycomb possessed stronger impact resistance and better load-bearing capacity than the hexagonal honeycomb under impact in this study. The equivalent method could be applied to select the optimum honeycomb based on requirements and improve the efficiency of the double V-wing honeycomb.

1997 ◽  
Vol 272 (1) ◽  
pp. H425-H437 ◽  
Author(s):  
M. J. Vonesh ◽  
C. H. Cho ◽  
J. V. Pinto ◽  
B. J. Kane ◽  
D. S. Lee ◽  
...  

A method employing intravascular ultrasound (IVUS) and simultaneous hemodynamic measurements, with resultant finite element analysis (FEA) of accurate three-dimensional IVUS reconstructions (3-DR), was developed to estimate the regional distribution of arterial elasticity. Human peripheral arterial specimens (iliac and femoral, n = 7) were collected postmortem and perfused at three static transmural pressures: 80, 120, and 160 mmHg. At each pressure, IVUS data were collected at 2.0-mm increments through a 20.0-mm segment and used to create an accurate 3-DR. Mechanical properties were determined over normotensive and hypertensive ranges. An FEA and optimization procedure was implemented in which the elemental elastic modulus was scaled to minimize the displacement error between the computer-predicted and actual deformations. The “optimized” elastic modulus (Eopt) represents an estimate of the component element material stiffness. A dimensionless variable (beta), quantifying structural stiffness, was computed. Eopt of nodiseased tissue regions (n = 80) was greater than atherosclerotic regions (n = 88) for both normotensive (Norm) and hypertensive (Hyp) pressurization: Norm, 9.3 +/- 0.98 vs. 3.5 +/- 0.30; Hyp, 11.3 +/- 0.72 vs. 8.5 +/- 0.47, respectively (mean +/- SE x 10(6) dyn/cm2; P < 0.01 vs. nondiseased). No differences in beta between nondiseased and atherosclerotic tissue were noted at Norm pressurization. With Hyp pressurization, beta of atherosclerotic regions were greater than nondiseased regions: 21.5 +/- 2.21 vs. 14.0 +/- 2.11, respectively (P < 0.03). This method provides a means to identify regional in vivo variations in mechanical properties of arterial tissue.


2017 ◽  
Author(s):  
Saman Naghieh ◽  
Mohammad Reza Karamooz-Ravari ◽  
Mohsen Badrossamay ◽  
Ehsan Foroozmehr

In recent years, thanks to additive manufacturing technology, researchers have gone towards the optimization of bone scaffolds for the bone reconstruction. Bone scaffolds should have appropriate biological as well as mechanical properties in order to play a decisive role in bone healing. Since the fabrication of scaffolds is time consuming and expensive, numerical methods are often utilized to simulate their mechanical properties in order to find a nearly optimum one. Finite element analysis is one of the most common numerical methods that is used in this regard. In this paper, a parametric finite element model is developed to assess the effects of layers penetration׳s effect on inter-layer adhesion, which is reflected on the mechanical properties of bone scaffolds. To be able to validate this model, some compression test specimens as well as bone scaffolds are fabricated with biocompatible and biodegradable poly lactic acid using fused deposition modeling. All these specimens are tested in compression and their elastic modulus is obtained. Using the material parameters of the compression test specimens, the finite element analysis of the bone scaffold is performed. The obtained elastic modulus is compared with experiment indicating a good agreement. Accordingly, the proposed finite element model is able to predict the mechanical behavior of fabricated bone scaffolds accurately. In addition, the effect of post-heating of bone scaffolds on their elastic modulus is investigated. The results demonstrate that the numerically predicted elastic modulus of scaffold is closer to experimental outcomes in comparison with as-built samples.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2777 ◽  
Author(s):  
Hamidreza Ahmadi Moghaddam ◽  
Pierre Mertiny

Polymers have become indispensable in many engineering applications because of their attractive properties, including low volumetric mass density and excellent resistance to corrosion. However, polymers typically lack in mechanical, thermal, and electrical properties that may be required for certain engineering applications. Therefore, researchers have been seeking to improve properties by modifying polymers with particulate fillers. In the research presented herein, a numerical modeling framework was employed that is capable of predicting the properties of binary or higher order composites with randomly distributed fillers in a polymer matrix. Specifically, mechanical properties, i.e., elastic modulus, Poisson’s ratio, and thermal expansion coefficient, were herein explored for the case of size-distributed spherical filler particles. The modeling framework, employing stochastic finite element analysis, reduces efforts for assessing material properties compared to experimental work, while increasing the level of accuracy compared to other available approaches, such as analytical methods. Results from the modeling framework are presented and contrasted with findings from experimental works available in the technical literature. Numerical predictions agree well with the non-linear trends observed in the experiments, i.e., elastic modulus predictions are within the experimental data scatter, while numerical data deviate from experimental Poisson’s ratio data for filler volume fractions greater than 0.15. The latter may be the result of morphology changes in specimens at higher filler volume fractions that do not comply with modelling assumptions.


2011 ◽  
Vol 243-249 ◽  
pp. 1461-1465
Author(s):  
Chuan Min Zhang ◽  
Chao He Chen ◽  
Ye Fan Chen

The paper makes an analysis of the reinforced concrete beams with exterior FRP Shell in Finite Element, and compares it with the test results. The results show that, by means of this model, mechanical properties of reinforced concrete beams with exterior FRP shell can be predicted better. However, the larger the load, the larger deviation between calculated values and test values. Hence, if more accurate calculation is required, issues of contact interface between the reinforced concrete beams and the FRP shell should be taken into consideration.


10.2341/08-73 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 223-229 ◽  
Author(s):  
A. O. Spazzin ◽  
D. Galafassi ◽  
A. D. de Meira-Júnior ◽  
R. Braz ◽  
C. A. Garbin

Clinical Relevance According to finite element analysis, the zirconia ceramic post created higher stress levels in the post and slightly less in dentin compared with glass fiber posts. Resin cement with a high elastic modulus created higher stress levels in the cement layer. The different film thicknesses of cement did not create significant changes in stress levels.


2021 ◽  
Author(s):  
Richárd Horváth ◽  
Vendel Barth ◽  
Viktor Gonda ◽  
Mihály Réger ◽  
Imre Felde

Abstract In this paper, we study the energy absorption of metamaterials composed of unit cells whose special geometry makes the cross-sectional area and the volume of the bodies generated from them constant (for the same enclosing box dimensions). After a parametric description of such special geometries, we analyzed by finite element analysis the deformation of the metamaterials we have designed during compression. We 3D printed the designed metamaterials from plastic to subject them to real compression. The results of the finite element analysis were compared with the real compaction results. Then, for each test specimen, we plotted its compaction curve. By fitting a polynomial to the compaction curves and integrating it (area under the curve), the energy absorption of the samples can be obtained. As a result of these investigations, we drew a conclusion about the relationship between energy absorption and cell number.


Sign in / Sign up

Export Citation Format

Share Document