The performance of a centrifugal compressor with a tandem impeller in off-design conditions

Author(s):  
Ziliang Li ◽  
Xingen Lu ◽  
Ge Han ◽  
Yanfeng Zhang ◽  
Shengfeng Zhao ◽  
...  

Centrifugal compressors often suffer relatively low efficiency and a terrible operating range particularly due to the complex flow structure and intense impeller/diffuser interaction. Numerous studies have focused on improving the centrifugal compressor performance using many innovative ideas, such as the tandem impeller, which has become increasingly attractive due to its ability to achieve the flow control with no additional air supply configurations and control costs in compressor. However, few studies that attempted to the investigation of tandem impeller have been published until now and the results are always contradictory. To explore the potential of the tandem impeller to enhance the compressor performance and the underlying mechanism of the flow phenomena in the tandem impellers, this paper numerically investigated a high-pressure-ratio centrifugal compressor with several tandem impellers at off-design operating speeds. The results encouragingly demonstrate that the tandem impeller can achieve a performance enhancement over a wide range of operating conditions. Approximately 1.8% maximum enhancement in isentropic efficiency and 5.0% maximum enhancement in operating range are achieved with the inducer/exducer circumferential displacement of [Formula: see text] = 25% and 50%, respectively. The observed stage performance gain of the tandem impellers decreases when the operating speed increases due to the increased inducer shock, increased wake losses, and deteriorated tandem impeller discharge flow uniformity. In addition, the tandem impeller can extend the impeller operating range particularly at low rotation speeds, which is found to be a result from the suppression of the low-momentum fluid radial movement. The results also indicate that the maximum flux capacity of the tandem impeller decreases due to the restriction of the inducer airfoil Kutta–Joukowsky condition.

Author(s):  
Timothy C. Allison ◽  
Natalie R. Smith ◽  
Robert Pelton ◽  
Jason C. Wilkes ◽  
Sewoong Jung

Successful implementation of sCO2 power cycles requires high compressor efficiency at both the design-point and over a wide operating range in order to maximize cycle power output and maintain stable operation over a wide range of transient and part-load operating conditions. This requirement is particularly true for air-cooled cycles where compressor inlet density is a strong function of inlet temperature that is subject to daily and seasonal variations as well as transient events. In order to meet these requirements, a novel centrifugal compressor stage design was developed that incorporates multiple novel range extension features, including a passive recirculating casing treatment and semi-open impeller design. This design, presented and analyzed for CO2 operation in a previous paper, was fabricated via direct metal laser sintering and tested in an open-loop test rig in order to validate simulation results and the effectiveness of the casing treatment configuration. Predicted performance curves in air and CO2 conditions are compared, resulting in a reduced diffuser width requirement for the air test in order to match design velocities and demonstrate the casing treatment. Test results show that the casing treatment performance generally matched computational fluid dynamics (CFD) predictions, demonstrating an operating range of 69% and efficiency above air predictions across the entire map. The casing treatment configuration demonstrated improvements over the solid wall configuration in stage performance and flow characteristics at low flows, resulting in an effective 14% increase in operating range with a 0.5-point efficiency penalty. The test results are also compared to a traditional fully shrouded impeller with the same flow coefficient and similar head coefficient, showing a 42% range improvement over traditional designs.


Author(s):  
Levi André B. Vigdal ◽  
Lars E. Bakken

The introduction of variable inlet guide vanes (VIGVs) upfront of a compressor stage affects performance and permits tuning for off-design conditions. This is of great interest for emerging technology related to subsea compression. Unprocessed gas from the wellhead will contain liquid condensate, which affects the operational condition of the compressor. To investigate the effect of guide vanes on volume flow and pressure ratio in a wet gas compressor, VIGVs are implemented upfront of a centrifugal compressor stage to control the inlet flow direction. The guide vane geometry and test rig setup have previous been presented. This paper documents how changing the VIGV setting affects compressor performance under dry and wet operating conditions. The reduced performance effect and operating range at increased liquid content are of specific interest. Also documented is the change in the VIGV effect relative to the setting angle.


1990 ◽  
Vol 112 (1) ◽  
pp. 25-29 ◽  
Author(s):  
H. Hayami ◽  
Y. Senoo ◽  
K. Utsunomiya

Low-solidity circular cascades, conformally transformed from high-stagger linear cascades of double-circular-arc vanes with solidity 0.69, were used as a part of the diffuser system of a transonic centrifugal compressor. Performance test results were compared with data of the same compressor with a vaneless diffuser. Good compressor performance and a wider flow range as well as a higher pressure ratio and a higher efficiency, superior to those with a vaneless diffuser, where the flow range was limited by choke of the impeller, were demonstrated. The test circular cascade diffusers demonstrated a good pressure recovery over a wide range of flow angles, even when the inflow Mach number to the cascade was over unity.


Author(s):  
A. Whitfield ◽  
A. H. Abdullah

The performance requirements of centrifugal compressors usually include a broad operating range between surge and choke. This becomes increasingly difficult to achieve as increased pressure ratio is demanded. In order to suppress the tendency to surge and extend the operating range at low flow rates inlet swirl is often considered through the application of inlet guide vanes. To generate high inlet swirl angles efficiently an inlet volute has been applied as the swirl generator, and a variable geometry design developed in order to provide zero swirl. The variable geometry approach can be applied to progressively increase the swirl or to switch rapidly from zero swirl to maximum swirl. The variable geometry volute and the swirl conditions generated are described. The performance of a small centrifugal compressor is presented for a wide range of inlet swirl angles. In addition to the basic performance characteristics of the compressor the onset of flow reversals at impeller inlet are presented, together with the development of pressure pulsations, in the inlet and discharge ducts, through to full surge. The flow rate at which surge occurred was shown, by the shift of the peak pressure condition and by the measurement of the pressure pulsations, to be reduced by over 40%.


Author(s):  
Mingyang Yang ◽  
Ricardo Martinez-Botas ◽  
Yangjun Zhang

The operating range of a centrifugal compressor, determined by surge and choke flow rate, is a key issue for turbocharging since a vehicle internal combustion engine (ICE) is usually operated across a wide range. In this paper a new flow control method is developed and validated numerically, in which an array of circumferentially distributed holes is designed in the inner wall of the inlet duct of a high pressure ratio centrifugal compressor of a turbocharger. Firstly the numerical method is validated by experimental results of the original turbocharging centrifugal compressor with a pressure ratio of 4. Next the validated method is used to investigate the new flow control method and its effect on the compressor’s performance. Results show that the method can enhance the compressor stability and widen the operating range effectively at all investigated speeds. At meantime, the choke flow reduces slightly. The flow details in the compressor are further analysed according to the CFD results. It is found that the flow near the blade tip at inlet is pre-swirled by the method as the conventional IGV does while the flow in the middle span or near the hub remains in an axial direction. As a result, the stability of the compressor is enhanced by the pre-swirl effect at the tip while minimally sacrificing the choke flow rate, thus the map is extended effectively by the flow control method.


Author(s):  
Michele Marconcini ◽  
Filippo Rubechini ◽  
Andrea Arnone ◽  
Seiichi Ibaraki

The flow field of a high pressure ratio centrifugal compressor for turbocharger applications is investigated using a three-dimensional Navier-Stokes solver. The compressor is composed of a double-splitter impeller followed by a vaned diffuser. The flow field of the transonic open-shrouded impeller is highly three-dimensional, and it is influenced by shock waves, tip leakage vortices and secondary flows. Their interactions generate complex flow structures which are convected and distorted through the impeller blades. Both steady and unsteady computations are performed in order to understand the physical mechanisms which govern the impeller flow field while the operation ranges from choke to surge. Detailed Laser Doppler Velocimetry (LDV) flow measurements are available at various cross-sections inside the impeller blades at both design and off-design operating conditions.


1998 ◽  
Vol 120 (3) ◽  
pp. 487-493 ◽  
Author(s):  
A. Whitfield ◽  
A. H. Abdullah

The performance requirements of centrifugal compressors usually include a broad operating range between surge and choke. This becomes increasingly difficult to achieve as increased pressure ratio is demanded. In order to suppress the tendency to surge and extend the operating range at low flow rates, inlet swirl is often considered through the application of inlet guide vanes. To generate high inlet swirl angles efficiently, an inlet volute has been applied as the swirl generator, and a variable geometry design developed in order to provide zero swirl. The variable geometry approach can be applied to increase the swirl progressively or to switch rapidly from zero swirl to maximum swirl. The variable geometry volute and the swirl conditions generated are described. The performance of a small centrifugal compressor is presented for a wide range of inlet swirl angles. In addition to the basic performance characteristics of the compressor, the onsets of flow reversals at impeller inlet are presented, together with the development of pressure pulsations, in the inlet and discharge ducts, through to full surge. The flow rate at which surge occurred was shown, by the shift of the peak pressure condition and by the measurement of the pressure pulsations, to be reduced by over 40 percent.


Energies ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2711 ◽  
Author(s):  
Nima Khoshkalam ◽  
Mohammad Mojaddam ◽  
Keith R. Pullen

The performance of an automotive turbocharger centrifugal compressor has been studied by developing a comprehensive one-dimensional (1D) code as verified through experimental results and a three-dimensional (3D) model. For 1D analysis, the fluid stream in compressor is modeled using governing gas dynamics equations and the loss mechanisms have been investigated and added to the numerical model. The objective is to develop and offer a 1D model, which considers all loss mechanisms, slip, blockage and also predicts the surge margin and choke conditions. The model captures all features from inlet duct through to volute discharge. Performance characteristics are obtained using preliminary geometry and the blade characteristics. A 3D numerical model was also created and a viscous solver used for investigating the compressor characteristics. The numerical model results show good agreement with experimental data through compressor pressure ratio and efficiency. The effect of the main compressor dimensions on compressor performance has been investigated for wide operating range and the portions of each loss mechanism in the impeller. Higher pressure ratio is achievable by increasing impeller blade height at outlet, impeller blade angle on inlet, diffuser outlet diameter and by decreasing impeller shroud diameter at inlet and blade angle at outlet. These changes may cause unfavorable consequences such as a lower surge margin or shorter operating range, which should be compromised with favorable changes. At lower rotational speeds, impeller skin friction mainly impacts the performance and at higher rotational speeds, impeller diffusion, blade loading and recirculation losses are more important. The results allow the share of each loss mechanism to be quantified for different mass flow rates and rotational speed, shedding new light on which losses are most important for which conditions. For a turbocharger, which must operate over a wide range of conditions, these results bring new insight to engineers seeking to optimize the compressor design as part of an internal combustion engine system.


Author(s):  
H. Hayami ◽  
Y. Senoo ◽  
K. Utsunomiya

Low-solidity circular cascades, conformally transformed from high-stagger linear cascades of double-circular-arc vanes with solidity 0.69, were used as a part of the diffuser system of a transonic centrifugal compressor. Performance test results were compared with data of the same compressor with a vaneless diffuser. Good compressor performance, a wider flow range as well as a higher pressure ratio and a higher efficiency, superior to those with a vaneless diffuser, where the flow range was limited by choke of the impeller, were demonstrated. The test circular cascade diffusers demonstrated a good pressure recovery over a wide range of flow angles, even when the inflow Mach number to the cascade was over unity.


Author(s):  
Timothy C. Allison ◽  
Natalie R. Smith ◽  
Robert Pelton ◽  
Sewoong Jung ◽  
Jason C. Wilkes

Successful implementation of sCO2 power cycles requires high compressor efficiency at both the design-point and over a wide operating range in order to maximize cycle power output and maintain stable operation over a wide range of transient and part-load operating conditions. This requirement is particularly true for air-cooled cycles where compressor inlet density is a strong function of inlet temperature that is subject to daily and seasonal variations as well as transient events. In order to meet these requirements, a novel centrifugal compressor stage design was developed that incorporates multiple novel range extension features, including a passive recirculating casing treatment and semi-open impeller design. This design, presented and analyzed for CO2 operation in a previous paper, was fabricated via direct metal laser sintering and tested in an open-loop test rig in order to validate simulation results and the effectiveness of the casing treatment configuration. Predicted performance curves in air and CO2 conditions are compared, resulting in a reduced diffuser width requirement for the air test in order to match design velocities and demonstrate the casing treatment. Test results show that the casing treatment performance generally matched CFD predictions, demonstrating an operating range of 69% and efficiency above air predictions across the entire map. The casing treatment configuration demonstrated improvements over the solid wall configuration in stage performance and flow characteristics at low flows, resulting in an effective 14% increase in operating range with a 0.5-point efficiency penalty. The test results are also compared to a traditional fully shrouded impeller with the same flow coefficient and similar head coefficient, showing a 42% range improvement over traditional designs.


Sign in / Sign up

Export Citation Format

Share Document