The impact of design ventilation rates on the indoor air quality in residential buildings: An Italian case study

2016 ◽  
Vol 26 (10) ◽  
pp. 1397-1419 ◽  
Author(s):  
Roberta Moschetti ◽  
Salvatore Carlucci

The paper investigates the effects on building indoor air quality (IAQ) resulting from the choice of different design ventilation rates. A reference residential building was analysed by means of the multizone modelling software CONTAM, by monitoring the concentration of two pollutants: occupant-generated carbon dioxide (CO2) and total volatile organic compounds (TVOC) from indoor sources. A demand-controlled ventilation strategy based on building occupancy was implemented and users' presence schedules were defined. Specifically, the evolution of indoor pollutant concentrations was investigated when the design ventilation rates, recommended by two IAQ-related standards (the Italian UNI 10339 and the European EN 15251), were implemented through a mechanical ventilation system. Different results regarding the IAQ level were achieved accordingly to the dissimilar ventilation rates. After a statistical analysis on the distributions of CO2 and TVOC concentrations, EN 15251 outcomes showed overall better results of the analysed statistical metrics, i.e. prevalence, sensitivity and accuracy. Indeed, the EN 15251 design airflows led to indoor conditions that were more often classified either in the correct air quality class or in a higher class. Finally, a better alignment between the national and European IAQ standards is recommended, especially in terms of airflows, air quality classes and pollutant limit values.

2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.


2019 ◽  
Vol 111 ◽  
pp. 04043
Author(s):  
Louis Cony-Renaud-Salis ◽  
Nouamane Belhaj ◽  
Olivier Ramalho ◽  
Marc Abadie

Home represents an important part of the time spent indoors and is the emblematic place of a family need, e.g. well-being, comfort and safety. In France, health agencies provide information and raise the awareness of the public on health risks and on factors likely to affect the quality of indoor air. However, indoor air quality remains difficult to assess for health investigators. A solution would be to resort to field measurements, but they are expensive and hard to apply to a large-scale population when considering the numerous pollutants found indoors. Therefore, numerical simulation represents a good alternative when accurate and realistic input data are used. We already designed such a model of a dwelling prototype using a type 98 coupling procedure between CONTAM (airflow rates and pollutants concentration determination) and TRNSYS (thermal and moisture calculation). We paid a lot of attention to the details that we thought were important: dwelling multi-zonal representation, envelope airtightness, ventilation system elements (pressure driven inlet and outlet, ducts, fan characteristics), presence of furniture, people activity and location… Nevertheless, the design of this simulation requires a very specific care. This very last point naturally induces a debate: is it necessary to design the simulation to be as accurate and realistic as it actually is, or will a simpler model provide similar results? In this study, we aim to answer that question by evaluating the sensitivity of the ULR-IAQ multipollutant index, defined in a previous study, to different levels of modelling complexity.


2012 ◽  
Vol 12 (11) ◽  
pp. 5055-5076 ◽  
Author(s):  
X. Querol ◽  
T. Moreno ◽  
A. Karanasiou ◽  
C. Reche ◽  
A. Alastuey ◽  
...  

Abstract. From an environmental perspective, the underground metro system is one of the cleanest forms of public transportation in urban agglomerations. Current studies report contradicting results regarding air quality in the metro systems: whereas some reveal poor air quality, others report PM levels which are lower or of the same order of magnitude than those measured in traffic sites above ground level. The present work assesses summer and winter indoor air quality and passenger exposure in the Barcelona metro, focusing on PM levels and their metal contents. In addition, the impact on indoor air quality of platform screen door systems (automated systems consisting of closed rail track and platforms) is evaluated, to determine whether these systems reduce passenger exposure to PM when compared with conventional systems (open tracks and platforms). In the Barcelona metro PM levels inside the trains in summer are amongst the lowest reported for worldwide metro systems (11–32 μg m−3 PM2.5). This is most likely due to the air conditioning system working in all carriages of the Barcelona metro during the whole year. Levels were considerably higher on the platforms, reaching mean levels of 46 and 125 μg m3 in the new (L9) and old (L3) lines, respectively. PM10 data are also reported in the present study, but comparison with other metro systems is difficult due to the scarcity of data compared with PM2.5. Results showed distinct PM daily cycles, with a drastic increase from 06:00 to 07:00 a.m., a diurnal maximum from 07:00 to 10:00 p.m., and marked decrease between 10:00 p.m. and 05:00 a.m. The elements with the highest enrichment were those associated with wheel or brake abrasion products (Ba, Fe, Cu, Mn, Cr, Sb, As, Mo, Co, Sr, among others). Laminar hematite (Fe2O3) was the dominant particle type, being mainly originated by mechanical abrasion of the rail track and wheels. Regarding passenger exposure to PM, the contribution of commuting by metro was estimated to account for around 10% of the daily exposure. However, this contribution may be one order of magnitude higher when specific matals are considered. Finally, we conclude that the implementation of platform screen door systems results in reductions of both PM levels and metal concentrations. In addition an advanced optimized ventilation system gave even a much higher efficiency in reducing exposure to PM of metro commuters. Combining these two features PM exposure levels in the platforms may be reduced down by a factor of 7 with respect the old subway lines in Barcelona.


2017 ◽  
Vol 25 (2) ◽  
pp. 1-6
Author(s):  
Imrich Sánka ◽  
Veronika Földváry

Abstract This study investigates the impact of energy renovation on the indoor air quality of an apartment building during the heating season. The study was performed in one residential building before and after its renovation. An evaluation of the indoor air quality was performed using objective measurements and a subjective survey. The concentration of CO2 was measured in the bedrooms, and a sampling of the total volatile compounds (TVOC) was performed in the living rooms of the selected apartments. Higher concentrations of CO2 and TVOC were observed in the residential building after its renovation. The concentrations of CO2, and TVOC in some of the cases exceeded the recommended maximum limits, especially after implementing energy-saving measures on the building. The average air exchange rate was visibly higher before the renovation of the building. The current study indicates that large-scale renovations may reduce the quality of an indoor environment in many apartments, especially in the winter season.


Climate ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 32
Author(s):  
Priyadarsini Rajagopalan ◽  
Nigel Goodman

Exposure to bushfire smoke is associated with acute and chronic health effects such as respiratory and cardiovascular disease. Residential buildings are important places of refuge from bushfire smoke, however the air quality within these locations can become heavily polluted by smoke infiltration. Consequently, some residential buildings may offer limited protection from exposure to poor air quality, especially during extended smoke events. This paper evaluates the impact of bushfire smoke on indoor air quality within residential buildings and proposes strategies and guidance to reduce indoor levels of particulates and other pollutants. The paper explores the different monitoring techniques used to measure air pollutants and assesses the influence of the building envelope, filtration technologies, and portable air cleaners used to improve indoor air quality. The evaluation found that bushfire smoke can substantially increase the levels of pollutants within residential buildings. Notably, some studies reported indoor levels of PM2.5 of approximately 500µg/m3 during bushfire smoke events. Many Australian homes are very leaky (i.e., >15 ACH) compared to those in countries such as the USA. Strategies such as improving the building envelope will help reduce smoke infiltration, however even in airtight homes pollutant levels will eventually increase over time. Therefore, the appropriate design, selection, and operation of household ventilation systems that include particle filtration will be critical to reduce indoor exposures during prolonged smoke events. Future studies of bushfire smoke intrusion in residences could also focus on filtration technologies that can remove gaseous pollutants.


2021 ◽  
pp. 1420326X2110171
Author(s):  
Samuel Stamp ◽  
Esfand Burman ◽  
Clive Shrubsole ◽  
Lia Chatzidiakou ◽  
Dejan Mumovic ◽  
...  

The indoor air quality (IAQ) of five low-energy London apartments has been assessed through the measurement of 16 key pollutants, using continuous and diffusive methods across heating and non-heating seasons. This case study approach aimed to assess the presence of pollutants within low-energy apartments and to better understand the role of ventilation and seasonal variations in indoor air quality. The results indicate strong seasonal variations, driven by increased natural ventilation rates over the summer monitoring period. A combined metric for indoor and outdoor pollutants ( Itot) suggests that the IAQ in the winter ( Itot = 17.7) is more than twice as bad as that seen in the summer ( Itot = 8.6). Formaldehyde concentrations were lower in the non-heating season, indicating increased ventilation rates more than offset increased off-gassing, in contrast to findings in other studies. However, increased summertime ventilation rates were observed to increase the proportion of outdoor pollutants entering the internal environment. This resulted in higher indoor concentrations of NO2 in the summer than the winter, despite significant reductions in outdoor concentrations. These results demonstrate the impact of ventilation practices upon IAQ, the influence of occupant actions and the complex relationship ventilation rates play in balancing indoor and outdoor sources of air pollution.


2019 ◽  
Vol 111 ◽  
pp. 06047
Author(s):  
Motoya Hayashi ◽  
Hoon kim ◽  
Yoshinori Honma ◽  
Junichiro Matsunaga

In order to retain good indoor air quality through the year in detached houses with passive ventilation systems, the authors investigated a mechanical control air-supply method. Firstly, indoor environments in houses with passive ventilation systems with thermal dampers, were examined using a simulation program (Fresh). Secondly, a passive ventilation system with a thermal damper, an under-floorheating system with a heat pump and were installed in an airtight house at Maebashi in Japan and measurements on its ventilation characteristics and indoor air quality were made. The simulation results showed that if the thermal damper is well tuned, this mechanically controlled air-supply opening keeps ventilation rates adequate through the year especially in airtight houses. The measurement results showed that the ventilation rates were kept above the required level through the year and the TVOC concentration decreases from 3000 to 200 μg/m3 in 5 months after the construction.


2012 ◽  
Vol 12 (3) ◽  
pp. 6655-6713 ◽  
Author(s):  
X. Querol ◽  
T. Moreno ◽  
A. Karanasiou ◽  
C. Reche ◽  
A. Alastuey ◽  
...  

Abstract. From an environmental perspective, the underground metro system is one of the cleanest forms of public transportation in urban agglomerations. Current studies report contradicting results regarding air quality in the metro systems: whereas some reveal poor air quality, others report PM levels which are lower or of the same order of magnitude than those measured in traffic sites above ground level. The present work assesses summer indoor air quality and passenger exposure in the Barcelona metro, focusing on PM levels and their metal contents. In addition, the impact on indoor air quality of platform screen door systems (automated systems consisting of closed rail track and platforms) is evaluated, to determine whether these systems reduce passenger exposure to PM when compared with conventional systems (open tracks and platforms). In the Barcelona metro, PM levels inside the trains in summer are amongst the lowest reported for worldwide metro systems (11–32 μPM2.5 m−3). This is most probably due to the air conditioning system working in all carriages of the Barcelona metro during the whole year. On the platforms, levels were considerably higher, reaching mean levels of 59 and 88 μgPM2.5 m−3 in the new (L9) and old (L3) lines, respectively. PM10 data are also reported in the present study, but comparison with other metro systems is more difficult due to the scarcity of data compared with PM2.5. Results showed clear PM daily cycles, with a drastic increase from 06:00 to 07:00 a.m., a diurnal maximum from 07:00 a.m. to 10:00 p.m., and marked decreases between 10:00 p.m. and 05:00 a.m. The elements with the highest enrichment are those associated with wheel or brake abrasion products (Ba, Fe, Cu, Mn, Cr, Sb, As, Mo, Co, Sr, among others). Laminar hematite (Fe2O3) was the dominant particle type, being mainly originated by mechanical abrasion of the rail track and wheels. Regarding passenger exposure to PM inside the metro system, the contribution of commuting by metro was estimated to account for around 10% of the daily exposure. Finally, we conclude that the implementation of platform screen door systems results in reductions of both PM levels and metal concentrations, but in addition an advanced optimized ventilation system gave even a much higher efficiency in reducing PM exposure to metro commuters. Combining these two features PM exposure levels in the platforms may be reduced down by a factor of 7 with respect the old subway lines in Barcelona.


Author(s):  
Alejandro Moreno-Rangel ◽  
Tim Sharpe ◽  
Gráinne McGill ◽  
Filbert Musau

Indoor air quality (IAQ) is a critical consideration in airtight buildings that depend on mechanical ventilation, such as those constructed to the Passivhaus standard. While previous reviews of IAQ on Passivhaus-certified buildings foccused on offices, this study examines residential buildings. A summary of data collection methods and pollutant concentrations is presented, followed by a critical discussion of the impact of Passivhaus design strategies on IAQ. This review indicates that IAQ in Passivhaus-certified dwellings is generally better than in conventional homes, but both occupant behaviour and pollution from outdoor sources play a significant role in indoor concentrations. Moreover, there are differences in data collection and reporting methods. Many of the available studies depend on short-term IAQ monitoring of less than two weeks, making it difficult to determine the longer impact of housing design on IAQ and occupants’ well-being. There is also a lack of studies from non-European countries. Future research should focus on investigating associations between IAQ and Passivhaus design strategies in hot and humid climates, where evidence is particularly lacking. Further effort is also required to investigate potential links between occupant’s perception of IAQ and physical exposure to indoor pollution. Finally, the lack of homogeneous monitoring and reporting methods for IAQ studies needs to be addressed.