scholarly journals Evaluation of Different Intraarticular Injection Therapies with Gait Analysis in a Rat Osteoarthritis Model

Cartilage ◽  
2021 ◽  
pp. 194760352110460
Author(s):  
Ceyhun Çağlar ◽  
Halil Kara ◽  
Okan Ateş ◽  
Mahmut Uğurlu

Objective: Osteoarthritis (OA) is a degenerative disease that causes serious damage to joints, especially in elderly patients. The aim of study was to demonstrate the effectiveness of intraarticular therapies that are currently used or recently popularized in the treatment of OA. Design: The baseline values were determined by walking the rats on the CatWalk system. Afterwards, a monosodium iodoacetate (MIA)-induced knee OA model was created with intraarticular MIA, and the rats were walked again on the CatWalk system and post-OA values were recorded. At this stage, the rats were divided into 4 groups, and intraarticular astaxanthin, intraarticular corticosteroid, intraarticular hyaluronic acid, and intraarticular astaxanthin + hyaluronic acid were applied to the groups, respectively. The rats were walked once more and posttreatment values were obtained. Nine different dynamic gait parameters were used in the comparison. Results: Significant changes were measured in 6 of the 9 dynamic gait parameters after the MIA-induced knee OA model. While the best improvement was observed in run duration ( P = 0.0022), stride length ( P < 0.0001), and swing speed ( P = 0.0355) in the astaxanthin group, the results closest to basal values in paw print length ( P < 0.0001), paw print width ( P = 0.0101), and paw print area ( P = 0.0277) were seen in the astaxanthin + hyaluronic acid group. Conclusion: Astaxanthin gave better outcomes than corticosteroid and hyaluronic acid in both dynamic gait parameters and histological examinations. Intraarticular astaxanthin therapy can be a good alternative to corticosteroid and hyaluronic acid currently used in intraarticular therapy to treat OA.

Gerontology ◽  
2021 ◽  
pp. 1-10
Author(s):  
He Zhou ◽  
Catherine Park ◽  
Mohammad Shahbazi ◽  
Michele K. York ◽  
Mark E. Kunik ◽  
...  

<b><i>Background:</i></b> Cognitive frailty (CF), defined as the simultaneous presence of cognitive impairment and physical frailty, is a clinical symptom in early-stage dementia with promise in assessing the risk of dementia. The purpose of this study was to use wearables to determine the most sensitive digital gait biomarkers to identify CF. <b><i>Methods:</i></b> Of 121 older adults (age = 78.9 ± 8.2 years, body mass index = 26.6 ± 5.5 kg/m<sup>2</sup>) who were evaluated with a comprehensive neurological exam and the Fried frailty criteria, 41 participants (34%) were identified with CF and 80 participants (66%) were identified without CF. Gait performance of participants was assessed under single task (walking without cognitive distraction) and dual task (walking while counting backward from a random number) using a validated wearable platform. Participants walked at habitual speed over a distance of 10 m. A validated algorithm was used to determine steady-state walking. Gait parameters of interest include steady-state gait speed, stride length, gait cycle time, double support, and gait unsteadiness. In addition, speed and stride length were normalized by height. <b><i>Results:</i></b> Our results suggest that compared to the group without CF, the CF group had deteriorated gait performances in both single-task and dual-task walking (Cohen’s effect size <i>d</i> = 0.42–0.97, <i>p</i> &#x3c; 0.050). The largest effect size was observed in normalized dual-task gait speed (<i>d</i> = 0.97, <i>p</i> &#x3c; 0.001). The use of dual-task gait speed improved the area under the curve (AUC) to distinguish CF cases to 0.76 from 0.73 observed for the single-task gait speed. Adding both single-task and dual-task gait speeds did not noticeably change AUC. However, when additional gait parameters such as gait unsteadiness, stride length, and double support were included in the model, AUC was improved to 0.87. <b><i>Conclusions:</i></b> This study suggests that gait performances measured by wearable sensors are potential digital biomarkers of CF among older adults. Dual-task gait and other detailed gait metrics provide value for identifying CF above gait speed alone. Future studies need to examine the potential benefits of gait performances for early diagnosis of CF and/or tracking its severity over time.


Gerontology ◽  
2021 ◽  
pp. 1-10
Author(s):  
Chenzhen Du ◽  
Hongyan Wang ◽  
Heming Chen ◽  
Xiaoyun Fan ◽  
Dongliang Liu ◽  
...  

Aims: Using specials wearable sensors, we explored changes in gait and balance parameters, over time, in elderly patients at high risk of diabetic foot, wearing different types of footwear. This assessed the relationship between gait and balance changes in elderly diabetic patients and the development of foot ulcers, in a bid to uncover potential benefits of wearable devices in the prognosis and management of the aforementioned complication. Methods: A wearable sensor-based monitoring system was used in middle-elderly patients with diabetes who recently recovered from neuropathic plantar foot ulcers. A total of 6 patients (age range: 55–80 years) were divided into 2 groups: the therapeutic footwear group (n = 3) and the regular footwear (n = 3) group. All subjects were assessed for gait and balance throughout the study period. Walking ability and gait pattern were assessed by allowing participants to walk normally for 1 min at habitual speed. The balance assessment program incorporated the “feet together” standing test and the instrumented modified Clinical Test of Sensory Integration and Balance. Biomechanical information was monitored at least 3 times. Results: We found significant differences in stride length (p < 0.0001), stride velocity (p < 0.0001), and double support (p < 0.0001) between the offloading footwear group (OG) and the regular footwear group on a group × time interaction. The balance test embracing eyes-open condition revealed a significant difference in Hip Sway (p = 0.004), COM Range ML (p = 0.008), and COM Position (p = 0.004) between the 2 groups. Longitudinally, the offloading group exhibited slight improvement in the performance of gait parameters over time. The stride length (odds ratio 3.54, 95% CI 1.34–9.34, p = 0.018) and velocity (odds ratio 3.13, 95% CI 1.19–8.19, p = 0.033) of OG patients increased, converse to the double-support period (odds ratio 6.20, 95% CI 1.97–19.55, p = 0.002), which decreased. Conclusions: Special wearable devices can accurately monitor gait and balance parameters in patients in real time. The finding reveals the feasibility and effectiveness of advanced wearable sensors in the prevention and management of diabetic foot ulcer and provides a solid background for future research. In addition, the development of foot ulcers in elderly diabetic patients may be associated with changes in gait parameters and the nature of footwear. Even so, larger follow-up studies are needed to validate our findings.


2021 ◽  
Author(s):  
Miroslaw Latka ◽  
Klaudia Kozlowska ◽  
Bruce J. West

Abstract During treadmill walking, the subject’s stride length (SL) and duration (ST) yield a stride speed (SS) which fluctuates over a narrow range centered on the treadmill belt’s speed. We recently demonstrated that ST and SL trends are strongly correlated and serve as control manifolds about which the corresponding gait parameters fluctuate. The fundamental problem, which has not yet been investigated, concerns the contribution of SL and ST fluctuations to SS variability. To investigate this relation, we approximate SS variance by the linear combination of SL variance and ST variance, as well as their covariance. The combination coefficients are nonlinear functions of ST and SL mean values and, consequently, depend on treadmill speed. The approximation applies to constant speed treadmill walking and walking on a treadmill whose belt speed is perturbed by strong, high-frequency noise. In the first case, up to 80% of stride speed variance comes from SL fluctuations. In the presence of perturbations, the SL contribution decreases with increasing speed, but its lowest value is still twice as large as that of either ST variance or SL-ST covariance. The presented evidence supports the hypothesis that stride length adjustments are primarily responsible for speed maintenance during walking. Such a control strategy is evolutionarily advantageous due to the weak speed dependence of the SL contribution to SS variance. The ability to maintain speed close to that of a moving cohort did increase the chance of an individual’s survival throughout most of human evolution.


2018 ◽  
Vol 10 (2) ◽  
Author(s):  
Massimiliano Pau ◽  
Federica Corona ◽  
Roberta Pili ◽  
Carlo Casula ◽  
Marco Guicciardi ◽  
...  

This study aimed to investigate possible differences in spatio-temporal gait parameters of people with Parkinson’s Disease (pwPD) when they are tested either in laboratory using 3D Gait Analysis or in a clinical setting using wearable accelerometers. The main spatio-temporal gait parameters (speed, cadence, stride length, stance, swing and double support duration) of 31 pwPD were acquired: i) using a wearable accelerometer in a clinical setting while wearing shoes (ISS); ii) same as condition 1, but barefoot (ISB); iii) using an optoelectronic system (OES) undressed and barefoot. While no significant differences were found for cadence, stance, swing and double support duration, the experimental setting affected speed and stride length that decreased (by 17% and 12% respectively, P<0.005) when passing from the clinical (ISS) to the laboratory (OES) setting. These results suggest that gait assessment should be always performed in the same conditions to avoid errors, which may lead to inaccurate patient’s evaluations.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6795
Author(s):  
Darko Božić ◽  
Ivan Ćatović ◽  
Ana Badovinac ◽  
Larisa Musić ◽  
Matej Par ◽  
...  

Background: this study evaluates the clinical outcomes of a novel approach in treating deep intrabony defects utilizing papilla preservation techniques with a combination of hyaluronic acid (HA) and deproteinized porcine bone mineral. Methods: 23 patients with 27 intrabony defects were treated with a combination of HA and deproteinized porcine bone mineral. Clinical attachment level (CAL), pocket probing depth (PPD), gingival recession (REC) were recorded at baseline and 6 months after the surgery. Results: At 6 months, there was a significant CAL gain of 3.65 ± 1.67 mm (p < 0.001) with a PPD reduction of 4.54 ± 1.65 mm (p < 0.001), which was associated with an increase in gingival recession (0.89 ± 0.59 mm, p < 0.001). The percentage of pocket resolution based on a PPD ≤4 mm was 92.6% and the failure rate based on a PPD of 5 mm was 7.4%. Conclusions: the present findings indicate that applying a combined HA and xenograft approach in deep intrabony defects provides clinically relevant CAL gains and PPD reductions compared to baseline values and is a valid new approach in treating intrabony defects.


Author(s):  
Andzelika Pajchert Kozlowska ◽  
Lukasz Pawik ◽  
Lukasz Szelerski ◽  
Slawomir Zarek ◽  
Radoslaw Górski ◽  
...  

Abstract INTRODUCTION: The purpose of this study was a comprehensive assessment of the dynamic parameters of gait in patients who underwent Ilizarov treatment for nonunion of the tibia. MATERIALS AND METHODS: The experimental group consisted of24 individuals treated with the Ilizarov method for nonunion of the tibia.The control group comprised31healthy individuals,matched for BMI,sex,and age.The dynamic gait parameters in patients and in the control group were measured with a Zebris pedobarographic platform. RESULTS: The treatment group and the control group showed statistically significant differences in terms of the following gait parameters:Maximum force 1NOL(non-operated-limb),Time maximum force1OL(operated-limb),Time maximum force 1 NOL,Maximum force 2NOL,Time maximum force 2OL,and Maximum force forefoot OL.Most of the evaluated gait parameters were bilaterally similar in patients group.The only significant differences between the operated and non-operated limb were seen in terms of Time maximum force 2and Maximum force forefoot. CONCLUSIONS: The most pronounced abnormalities in dynamic gait parameters were observed in the forefoot.The patients treated with the Ilizarov method did not achieve a complete normalization of dynamic gait parameters,as their gait parameters did not equal those measured in the control group.The Ilizarov method for the treatment of tibial nonunion helps restore a symmetrical distribution of gait parameter values between the affected limb and the healthy limb.Patients with tibial nonunion treated with the Ilizarov method continue to show some abnormalities in their dynamic gait parameters after treatment.


Author(s):  
Luiz Fernado Biazus-Sehn ◽  
Rafael Reimann Baptista ◽  
Régis Gemerasca Mestriner ◽  
Bianca Pacheco Loss ◽  
Daniela Aldabe ◽  
...  

Real-world walking requires shifting attention from different cognitive demands to adapt gait. This study aims to evaluate the effect of dual tasking on spatiotemporal gait parameters of older adults. Participants were asked to perform a primary complex single-walking task, consisting of a fast-paced linear and a curved gait. Primary task was performed separately and simultaneously with different motor and cognitive secondary tasks. Spatiotemporal gait parameters, walk ratio, and walk stability ratio were measured. Apart from stride length, which stood relatively unchanged, gait speed and cadence were strongly affected by cognitive dual tasking. Cadence seems to be the most impacted by dual tasking during curved gait as it combines challenges of both primary and secondary tasks. Also, during curved phase, walking ratio was significantly lower and stability ratio was greater demonstrating that participants adopted a cautious gait where maintenance of stability took preference over efficiency.


2021 ◽  
Author(s):  
IlHyun Son ◽  
GyuChang Lee

Abstract Background: It has been reported the effects of a hinged ankle-foot orthosis on the gait ability of children with cerebral palsy. However, no studies investigated the effects of the dorsiflexion angle of the hinged ankle-foot orthosis on the spatiotemporal gait parameters of children with cerebral palsy. This study aimed to investigate the immediate effects of a 10° dorsiflexion inducing ankle-foot orthosis the spatiotemporal gait parameters of children with spastic diplegia compared to barefoot and a hinged ankle-foot orthosis.Methods: This study was cross-over design. 10 children with spastic diplegia were walked with barefoot, a hinged ankle-foot orthosis, and a 10° dorsiflexion inducing ankle-foot orthosis. GAITRite was used to collect the spatiotemporal gait parameters including gait velocity, cadence, step length, stride length, single leg support, and double leg support. Results: It showed that a 10° dorsiflexion inducing ankle-foot orthosis significantly improved the gait velocity, cadence, step length, stride length, single leg support, and double leg support than barefoot and a hinged ankle-foot orthosis (p<.05). Conclusion: The results of this study implied that a 10° dorsiflexion inducing ankle-foot orthosis could improve the gait ability of children with spastic diplegia more than barefoot or a hinged ankle-foot orthosis. High quality future studies will need to examine the effects of hinged ankle-foot orthosis on gait ability according to dorsiflexion angles.


2019 ◽  
Vol 33 (10) ◽  
pp. 1682-1687 ◽  
Author(s):  
Christian Werner ◽  
Georgia Chalvatzaki ◽  
Xanthi S Papageorgiou ◽  
Costas S Tzafestas ◽  
Jürgen M Bauer ◽  
...  

Objective: To assess the concurrent validity of a smart walker–integrated gait analysis system with the GAITRite® system for measuring spatiotemporal gait parameters in potential users of the smart walker. Design: Criterion standard validation study. Setting: Research laboratory in a geriatric hospital. Participants: Twenty-five older adults (⩾65 years) with gait impairments (habitual rollator use and/or gait speed <0.6 m/s) and no severe cognitive impairment (Mini-Mental State Examination ⩾17). Main measures: Stride, swing and stance time; stride length; and gait speed were simultaneously recorded using the smart walker–integrated gait analysis system and the GAITRite system while participants walked along a 7.8-m walkway with the smart walker. Concurrent criterion-related validity was assessed using the Bland–Altman method, percentage errors (acceptable if <30%), and intraclass correlation coefficients for consistency (ICC3,1) and absolute agreement (ICC2,1). Results: Bias for stride, swing and stance time ranged from −0.04 to 0.04 seconds, with acceptable percentage errors (8.7%–23.0%). Stride length and gait speed showed higher bias (meanbias (SD) = 0.20 (0.11) m; 0.19 (0.13) m/s) and not acceptable percentage errors (31.3%–42.3%). Limits of agreement were considerably narrower for temporal than for spatial-related gait parameters. All gait parameters showed good-to-excellent consistency (ICC3,1 = 0.72–0.97). Absolute agreement was good-to-excellent for temporal (ICC2,1 = 0.72–0.97) but only poor-to-fair for spatial-related gait parameters (ICC2,1 = 0.37–0.52). Conclusion: The smart walker–integrated gait analysis system has good concurrent validity with the GAITRite system for measuring temporal but not spatial-related gait parameters in potential end-users of the smart walker. Stride length and gait speed can be measured with good consistency, but with only limited absolute accuracy.


2017 ◽  
Vol 9 (9) ◽  
pp. 231-246 ◽  
Author(s):  
Mohit Bhandari ◽  
Raveendhara R. Bannuru ◽  
Eric M. Babins ◽  
Johanne Martel-Pelletier ◽  
Moin Khan ◽  
...  

Osteoarthritis (OA) is a chronic condition characterized by a loss of joint cartilage and is a major cause of disability in Canada, with an estimated CN$195 billion annual cost. Knee OA leads to persistent pain and loss of function, and treatment goals primarily focus on symptom relief and retention of function. Intra-articular hyaluronic acid (IAHA) has therapeutic benefits, and numerous recently published meta-analyses (MAs) and commentaries have highlighted new evidence on the role of IAHA therapy for knee OA. A diverse, multidisciplinary group of specialists met independently in closed sessions to review findings from eight MAs with literature search end dates no earlier than 2012 to address controversies surrounding IAHA therapy for mild-to-moderate knee OA within the Canadian treatment context. Outcomes from a total of eight MAs were reviewed, and consistent and statistically significant improvements in pain, function and stiffness up to 26 weeks were found with IAHA therapy compared with IA placebo or controls, regardless of MA size or trial quality. These findings are in line with those of a Cochrane review, another recent systematic review and patient satisfaction survey. Overall, three MAs reported outcomes based on molecular weight (MW), with the two reporting effect sizes showing significantly improved pain outcomes for higher compared with lower MW HAs. Recent evidence suggests that HA therapy is well tolerated with no increased risk of serious adverse events compared with placebo and the full therapeutic effect of IAHA therapy appears to have considerable clinical importance, consisting of the combined IA placebo and HA therapeutic effects. IAHA therapy is a well-tolerated and effective option for patients with mild-to-moderate knee OA failing first-line pharmacological therapy.


Sign in / Sign up

Export Citation Format

Share Document