Effect of bidirectional excitation on seismic performance of regular RC frame buildings designed for modern codes

2021 ◽  
pp. 875529302110478
Author(s):  
Payal Gwalani ◽  
Yogendra Singh ◽  
Humberto Varum

The existing practice to estimate seismic performance of a regular building is to carry out nonlinear time history analysis using two-dimensional models subjected to unidirectional excitations, even though the multiple components of ground motion can affect the seismic response, significantly. During seismic shaking, columns are invariably subjected to bending in two orthogonal vertical planes, which leads to a complex interaction of axial force with the biaxial bending moments. This article compares the seismic performance of regular and symmetric RC moment frame buildings for unidirectional and bidirectional ground motions. The buildings are designed and detailed according to the Indian codes, which are at par with the other modern seismic codes. A fiber-hinge model, duly calibrated with the biaxial experimental results, is utilized to simulate the inelastic behavior of columns under bidirectional bending. A comparison of the estimated seismic collapse capacity is presented, illustrating the importance of considering the bidirectional effects. The results from fragility analysis indicate that the failure probabilities of buildings under the bidirectional excitation are significantly higher as compared to those obtained under the unidirectional excitation.

2012 ◽  
Vol 28 (2) ◽  
pp. 621-637 ◽  
Author(s):  
Chun Ni ◽  
Shiling Pei ◽  
John W. van de Lindt ◽  
Steven Kuan ◽  
Marjan Popovski

In 2009, the British Columbia Building Code was amended to increase the allowable height of wood-frame residential buildings to six stories from four stories. This paper presents the details of a numerical study undertaken to understand the seismic performance of six-story wood-frame buildings designed in accordance with the 2006 British Columbia Building Code. To investigate the seismic behavior, a four-story building was used to represent the benchmark seismic performance prior to the amendment. Two independent analyses using computer programs DRAIN-3DX and SAPWood were carried out on representative buildings located in the city of Vancouver, BC, using a suite of 20 earthquake records scaled to the design seismic hazard level for the site. The analyses showed that six-story wood-frame buildings had similar performance to four-story wood-frame buildings.


2016 ◽  
Vol 16 (02) ◽  
pp. 1450094 ◽  
Author(s):  
Seyed Morteza Zinati Yazdi ◽  
Mohammad Taghi Kazemi

Heavy damages on structures caused by near field earthquakes in recent years has brought serious attention to this problem. An examination of previous records has shown significant differences for near field earthquakes, including a large energy pulse, unlike far field earthquakes. But as a general rule, the effects of near field earthquakes have been ignored in most building codes. The purpose of this paper is to investigate the effect of near field earthquakes on reinforced concrete (RC) moment frames. To achieve this goal, the Erduran damage index, an efficient way to calculate damage, was employed to analyze two 4- and 8-story RC moment frame buildings. The buildings with moderate and high ductility were designed by the strength criteria. Seven pairs of near field and far field earthquakes were scaled and used for dynamic nonlinear time history analysis. Using Erduran’s beam and column damage index, respectively, based on rotation and drift, the results from both near and far field earthquakes were compared. Moreover, for better assessment, 4-story buildings were evaluated from the performance based viewpoint of design. We observe from the results that most of the components of the structures under near field earthquakes sustained severe damages and in some cases even component failure. Components of the structures under near field earthquakes suffered from 30% more of damage, on average, than that under far field earthquakes.


2013 ◽  
Vol 671-674 ◽  
pp. 782-785
Author(s):  
Bin He ◽  
Jin Lai Pang ◽  
Cheng Qing Liu

For the lack of research in the longitudinal frame of prefabricated structure for its weak lateral stiffness, pushover analysis is conducted to evaluate the seismic performance of a fabricated concrete frame. Based on case study, the strengthening strategies with viscous dampers are analyzed. In view of the undesirable drift distribution and failure mode in the existing building, it is believed that arrangement of dampers should be designed to attain a uniform drift distribution. Based on the nonlinear time history analysis method, the strategy of damper allocation in vertical direction of the structure is investigated .Results indicate that a proper design might be attained based on the property of existing system, leading to a uniform drift distribution and better seismic performance.


Author(s):  
Kanthi Srirengan ◽  
Partha Chakrabarti ◽  
Rupak Ghosh

Two novel methods namely the Dominant Modes method and the All Modes method to predict the seismic-pushover load for the jacket-type structures are presented. Both of these methods are based on the linear superposition of the modal reactions. As a preliminary evaluation, the linear elastic response of a jacket structure subjected to seismic-pushover loads is compared with that obtained from the response spectrum analysis. Furthermore, the nonlinear inelastic behavior obtained from the seismic-pushover analysis is compared with that obtained from the nonlinear time-history analysis, for a portal frame subjected to El Centro earthquake motion. When more than one mode is dominant in an excitation direction, both the linear elastic and the nonlinear inelastic responses obtained using the loads generated from the All Modes method are representative of the reference solutions.


2016 ◽  
Vol 32 (4) ◽  
pp. 427-433
Author(s):  
H.-L. Wang ◽  
S.-W. Liu ◽  
Z. Zhang

AbstractTo study the seismic performance and the effects of different joint shapes for unbonded precast segmental bridge columns under low-reversed cyclic loading, two 3-D finite element (FE) models respectively using plane-contact joints and shear resistant joints were established. In the FE models, the mechanical behaviors of concrete and tendons were respectively described by the damage-plastic model and the bilinear model, and the contact criteria was based on Coulomb's Friction. The results of nonlinear time history analysis showed that the deformation of the columns was mainly composed of alternately open-closed joints, and the failure of the column was mainly caused by concrete crush on the bottom segment. Compared with two model's hysteresis loop, backbone curve, ductility and residual deformation, it was found that the column with shear resistant joints had longer stable period of strength, better ductility, and smaller residual displacement than the column with plane-contact joints, so it had better seismic performance.


2011 ◽  
Vol 243-249 ◽  
pp. 1396-1400
Author(s):  
Yong Sheng Qi ◽  
Feng Hua Zhao ◽  
Jun Wen Zhou

Influence of strength variability of braces on the weak shear type concentrically-braced steel frames is studied by pushover and nonlinear time history analysis method, which leads to a conclusion that the overstrength of brace has obviously detrimental influence on the seismic performance of the structure, induces stronger seismic reaction and higher seismic risk. Another valuable discovery is that after the area of the braces of weak shear type centrically-braced steel frames are determined according to the requirement of current codes, the designer can intentionally specify the structural steel of comparatively low strength (for example, the 2nd group in the paper taking 70% strength of steel Q235) for the brace, which can provide the structure more excellent seismic performance.


2012 ◽  
Vol 204-208 ◽  
pp. 2658-2661 ◽  
Author(s):  
Biao Wei ◽  
Shan Shan Li

As to improve bridges’ seismic performance, horizontal earthquake was isolated at the bottom of piers. With one pier system as the object of study, adopting nonlinear time history analysis analyzed the un-isolation system, the traditional isolation system and the new isolation system’s seismic performance especially when the actual earthquake was different from the design earthquake, in which the new isolation system was based on rolling balls. Results shows, as for the new isolation system, the internal force is independent of earthquake accelerations and earthquake periods, therefore, sympathetic vibration will not exist, and the internal force is always too small to destroy the system.


2014 ◽  
Vol 2014 ◽  
pp. 1-9
Author(s):  
David Kim ◽  
Eun Hee Sung ◽  
Kwan-Soon Park ◽  
Jaegyun Park

This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance of the MSD, dynamic loading tests are performed with three slim-type dampers manufactured at a real scale. Numerical simulations are also carried out by nonlinear time history analysis with a ten-story earthquake excited building structure. The seismic performance and cost-effectiveness of the MSD system are investigated according to the various installation configurations of the MSD system. From the results of numerical simulation and cost-effectiveness evaluation, it is shown that combinations of the MSD systems can effectively improve the seismic performance of earthquake excited building structures.


Buildings ◽  
2019 ◽  
Vol 9 (9) ◽  
pp. 201 ◽  
Author(s):  
Fujii

It is essential for the seismic design of a base-isolated building that the seismic response of the superstructure remains within the elastic range. The evaluation of the maximum seismic member force in a superstructure is thus an important issue. The present study predicts the maximum seismic member force of five- and fourteen-story reinforced concrete base-isolated frame buildings adopting pushover analysis. In the first stage of the study, the nonlinear dynamic (time-history) analysis of the base-isolated frame buildings is carried out, and the nonlinear modal responses of the first and second modes are calculated from pushover analysis results. In the second stage, a set of pushover analyses is proposed considering the combination of the first and second modal responses, and predicted maximum member forces are compared with the nonlinear time-history analysis results. Results show that the maximum member forces predicted in the proposed set of pushover analyses are satisfactorily accurate, while the results predicted considering only the first mode are inaccurate.


2011 ◽  
Vol 137 ◽  
pp. 149-153 ◽  
Author(s):  
Huan Jun Jiang ◽  
Bo Fu ◽  
Lao Er Liu

Due to its unique advantages, the steel-concrete hybrid structure has been widely used in tall buildings around the world. In Mainland China it has been utilized as one of the most popular structural types for super tall buildings. In this study the seismic performance of a code-exceeding tall building with the hybrid frame-tube structure to be constructed in Beijing is evaluated by numerical analysis. The analytic model of the structure is established with the aid of PERFORM-3D program, and the nonlinear time history analysis is performed by inputting four sets of earthquake ground motions. The elastic dynamic characteristics, the global displacement responses, the performance levels and the deformation demand-to-capacity ratios of structural components under different levels of earthquakes are presented. Numerical analysis results indicate that the hybrid structure has good seismic performance.


Sign in / Sign up

Export Citation Format

Share Document