scholarly journals Lung stereotactic body radiation therapy: personalized PTV margins according to tumor location and number of four-dimensional CT scans

2022 ◽  
Vol 17 (1) ◽  
Author(s):  
Pierre Trémolières ◽  
Ana Gonzalez-Moya ◽  
Amaury Paumier ◽  
Martine Mege ◽  
Julien Blanchecotte ◽  
...  

Abstract Objectives To characterise the motion of pulmonary tumours during stereotactic body radiation therapy (SBRT) and to evaluate different margins when creating the planning target volume (PTV) on a single 4D CT scan (4DCT). Methods We conducted a retrospective single-site analysis on 30 patients undergoing lung SBRT. Two 4DCTs (4DCT1 and 4DCT2) were performed on all patients. First, motion was recorded for each 4DCT in anterior–posterior (AP), superior-inferior (SI) and rightleft (RL) directions. Then, we used 3 different margins (3,4 and 5 mm) to create the PTV, from the internal target volume (ITV) of 4DCT1 only (PTV D1 + 3, PTV D1 + 4, PTV D1 + 5). We compared, using the Dice coefficient, the volumes of these 3 PTVs, to the PTV actually used for the treatment (PTVttt). Finally, new treatment plans were calculated using only these 3 PTVs. We studied the ratio of the D2%, D50% and D98% between each new plan and the plan actually used for the treatment (D2% PTVttt, D50% PTVttt, D50% ITVttt D98% PTVttt). Results 30 lesions were studied. The greatest motion was observed in the SI axis (8.8 ± 6.6 [0.4–25.8] mm). The Dice index was higher when comparing PTVttt to PTV D1 + 4 mm (0.89 ± 0.04 [0.82–0.98]). Large differences were observed when comparing plans relative to PTVttt and PTV D1 + 3 for D98% PTVttt (0.85 ± 0.24 [0.19–1.00]). and also for D98% ITVttt (0.93 ± 0.12 [0.4–1.0]).D98% PTVttt (0.85 ± 0.24 [0.19–1.00], p value = 0.003) was statistically different when comparing plans relative to PTVttt and PTV D1 + 3. No stastistically differences were observed when comparing plans relative to PTVttt and PTV D1 + 4. A difference greater than 10% relative to D98% PTVttt was found for only in one UL lesion, located under the carina. Conclusion A single 4DCT appears feasible for upper lobe lesions located above the carina, using a 4-mm margin to generate the PTV. Advance in knowledge Propostion of a personalized SBRT treatment (number of 4DCT, margins) according to tumor location (above or under the carina).

2020 ◽  
Vol 61 (2) ◽  
pp. 325-334
Author(s):  
Takashi Shintani ◽  
Mitsuhiro Nakamura ◽  
Yukinori Matsuo ◽  
Yuki Miyabe ◽  
Nobutaka Mukumoto ◽  
...  

Abstract The aim of this study was to assess the impact of fractional dose and the number of arcs on interplay effects when volumetric modulated arc therapy (VMAT) is used to treat lung tumors with large respiratory motions. A three (fractional dose of 4, 7.5 or 12.5 Gy) by two (number of arcs, one or two) VMAT plan was created for 10 lung cancer cases. The median 3D tumor motion was 17.9 mm (range: 8.2–27.2 mm). Ten phase-specific subplans were generated by calculating the dose on each respiratory phase computed tomography (CT) scan using temporally assigned VMAT arcs. We performed temporal assignment of VMAT arcs using respiratory information obtained from infrared markers placed on the abdomens of the patients during CT simulations. Each phase-specific dose distribution was deformed onto exhale phase CT scans using contour-based deformable image registration, and a 4D plan was created by dose accumulation. The gross tumor volume dose of each 4D plan (4D GTV dose) was compared with the internal target volume dose of the original plan (3D ITV dose). The near-minimum 4D GTV dose (D99%) was higher than the near-minimum 3D internal target volume (ITV) dose, whereas the near-maximum 4D GTV dose (D1%) was lower than the near-maximum 3D ITV dose. However, the difference was negligible, and thus the 4D GTV dose corresponded well with the 3D ITV dose, regardless of the fractional dose and number of arcs. Therefore, interplay effects were negligible in VMAT-based stereotactic body radiation therapy for lung tumors with large respiratory motions.


2021 ◽  
Author(s):  
Yanhua Duan ◽  
Yan Shao ◽  
Hua Chen ◽  
Hao Wang ◽  
Hengle Gu ◽  
...  

Abstract Purpose: The plan quality of the stereotactic body radiation therapy (SBRT) plan is affected by the patient’s planning target volume (PTV). The predictability of PTV volume and cut-off points were investigated to judge the suitability of manual and automatic plans for lung SBRT patients.Methods: The manual and automatic SBRT plans were retrospectively designed using the Pinnacle 16.2 treatment planning system (TPS) for 98 lung cancer patients. the suitability of manual and automatic plans for each patient is comprehensively evaluated. Receiver operating characteristic (ROC) analysis was used to investigate the predictability of PTV volume and determine the cut-off point. Once the cut-off point exists, all patients were divided into two groups according to this cut-off point. The Wilcoxon signed-rank test was performed for the dosimetric comparisons between the two groups. Results: ROC analysis showed that PTV volume (AUC [Area under curve]: 0.918, p= 0.005) has diagnostic power to predict the suitability of manual and automatic plans for lung SBRT patients. The cut-off points of 22.675cc were selected for PTV volume. Regardless of some comparable results, the CI, GI, V10, and V20 of automatic plans were found to be better than manual plans below the cut-off points, and the manual plan is superior to the automatic plan in HI, GI, heart d15cc, V10, V20 above the cut-off points.Conclusion: The PTV volume of cut-off points (22.675cc) are predictive of the suitability of manual and automatic plan using Pinnacle TPS for lung SBRT patients. Automatic plans were recommended for patients with PTV volumes less than 22.675cc, and manual plans can be tried for patients with larger PTV volumes.