scholarly journals Reverse shoulder arthroplasty vs BIO-RSA: clinical and radiographic outcomes at short term follow-up

Author(s):  
Nathan Kirzner ◽  
Eldho Paul ◽  
Ash Moaveni
2018 ◽  
Vol 27 (4) ◽  
pp. 701-710 ◽  
Author(s):  
Giovanni Merolla ◽  
Gilles Walch ◽  
Francesco Ascione ◽  
Paolo Paladini ◽  
Elisabetta Fabbri ◽  
...  

Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


BMJ Open ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. e040591
Author(s):  
Alex Marzel ◽  
Hans-Kaspar Schwyzer ◽  
Christoph Kolling ◽  
Fabrizio Moro ◽  
Matthias Flury ◽  
...  

PurposeClinical registries are essential for evaluation of surgical outcomes. The Schulthess Shoulder Arthroplasty Registry (SAR) was established in 2006 to evaluate safety, function, quality-of-life and patient satisfaction in patients undergoing shoulder arthroplasty.ParticipantsAdult patients undergoing anatomic or reverse shoulder joint replacement at the Schulthess Klinik, a high-volume, leading orthopaedic surgery centre in Zürich, Switzerland.Findings to dateBetween March 2006 and December 2019, the registry covered 98% of eligible operations. Overall, 2332 patients were enrolled with a total of 2796 operations and 11 147 person-years of follow-up. Mean age at baseline was 71 (range: 20–95), 65% were women. Most common indication was rotator cuff tears with osteoarthritis (42%) and the mean preoperative Constant Score was 31 (±15). The most frequent arthroplasty type was reverse, increasing from 61% in 2006–2010 to 86% in 2015–2019. Functional recovery peaked at 12-month postoperatively and did not show a clinically relevant deterioration during the first ten follow-up years. Since its establishment, the registry was used to address multiple pertinent clinical and methodological questions. Primary focus was on comparing different implant configurations (eg, glenosphere diameter) and surgical techniques (eg, latissimus dorsi transfer) to maximise functional recovery. Additionally, the cohort contributed to the determination of the clinical relevance and validity of radiological monitoring of cortical bone resorption and scapular notching. Finally, SAR data helped to demonstrate that returning to sports was among key patient expectations after reverse shoulder arthroplasty.Future plansAs first patients are approaching the 15 years follow-up landmark, the registry will continue providing essential data on long-term functional outcomes, implant stability, revision rates and aetiologies as well as patient satisfaction and quality-of-life. In addition to research and quality-control, the cohort data will be brought back to the patients by bolstering real-time clinical decision support.