scholarly journals Determining the stability of minimally displaced lateral humeral condyle fractures in children: ultrasound is better than arthrography

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Andreas Rehm ◽  
Tamás Kobezda ◽  
Elizabeth Ashby
2020 ◽  
Author(s):  
Xing Wu ◽  
Xiongtao Li ◽  
Shaowei Yang ◽  
Si Wang ◽  
Jingdong Xia ◽  
...  

Abstract Background: Evaluating of the articular cartilage status of the distal humeral epiphysis is difficult. Ultrasound imaging of the elbow is increasingly being used to confirm the integrity of the articular cartilage of minimally displaced lateral humeral condyle fractures in children with minimally displaced fractures. The aims of this study were to assess the correlations between ultrasound and arthrography findings for predicting the integrity of the cartilage hinge and to describe the utility of ultrasound in determining the need for pre-treatment.Methods: Thirty-nine patients with minimally displaced lateral humeral condyle fractures who underwent ultrasound and arthrography examinations before surgery from May 2018 to December 2019 were included in this study. Ultrasound and arthrography predictors of the cartilage hinge status were independently measured. The ultrasound and arthrography results were compared.Results: The mean displacement of the fractures was 3.1 mm (range, 2.0~5.0 mm). Arthrography showed incomplete fractures in 24 patients (61.5%) and complete fractures in 15 patients (38.5%). Ultrasound showed incomplete fractures in 25 patients (64.1%) and complete fractures in 14 patients (35.9%). The ultrasound and arthrography results of the integrity of the articular surface were consistent in 92.3% of the cases, including 23 that were predicted to have an intact articular surface and 13 that were predicted to have an incongruity articular surface. There was no correlation between the displacement and the fracture appearing complete on the ultrasound scan. The Pearson coefficient between ultrasound and arthrography for assessing the integrity of the articular surface was 0.837.Conclusions: Ultrasound and arthrography assessments of the integrity of the cartilage hinge status appear to be highly consistent. Ultrasound can be used as a complementary tool with arthrography to predict the integrity of the cartilage hinge status in children with minimally displaced lateral humeral condyle fractures.Level of evidence: Prospective study; level Ⅱ.


2020 ◽  
Author(s):  
Xing Wu ◽  
Xiongtao Li ◽  
Shaowei Yang ◽  
Si Wang ◽  
Jingdong Xia ◽  
...  

Abstract Background: The evaluation of the articular cartilage status of the distal humeral epiphysis is difficult. Ultrasound of the elbow is increasingly used to confirm the integrity of the articular cartilage of minimally displaced lateral humeral condyle fractures in children in minimally displaced fractures. The aim of this study was to assess the correlation between ultrasound with arthrography for predicting the integrity of the cartilage hinge and describe the utility of ultrasound in directing the need for pre-treatment. Methods: 39 patients with minimally displaced lateral humeral condyle fractures and underwent ultrasound and arthrography examinations before operation from May 2018 to December 2019 were included in this study. The ultrasound and arthrography predictors of the cartilage hinge status were independently measured. Result of ultrasound and arthrography were compared.Results: The mean displacement of fractures was 3.1 mm (range, 2.0~5.0 cm). The arthrography showed an incomplete fracture in 24 patients (61.5%) and complete in 15 patients (38.5%). The ultrasound showed an incomplete fracture in 25 patients (64.1%) and complete in 14 patients (35.9%). The ultrasound and arthrography evaluations of the integrity of the articular surface were consistent in 92.3% of the cases, including 23 were predicted to have an intact articular surface, and 13 were predicted to have incongruity articular surface. There was no correlation between displacement and the fracture being complete on ultrasound. The Pearson coefficient value of ultrasound and arthrography for assessing the integrity of the articular surface was 0.837. Conclusions: Ultrasound and arthrography assessments of the integrity of the cartilage hinge status appear to be highly consistent. Ultrasound can be used as a complementary tool with arthrography to predict the integrity of the cartilage hinge status of patients with minimally displaced lateral humeral condyle fractures in children.Level of evidence: Retrospective study; level Ⅳ.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xing Wu ◽  
Xiongtao Li ◽  
Shaowei Yang ◽  
Si Wang ◽  
Jingdong Xia ◽  
...  

Abstract Background Evaluating of the articular cartilage status of the distal humeral epiphysis is difficult. Ultrasound imaging of the elbow is increasingly being used to confirm the integrity of the articular cartilage of minimally displaced lateral humeral condyle fractures in children with minimally displaced fractures. The aims of this study were to assess the correlations between ultrasound and arthrography findings for predicting the integrity of the cartilage hinge and to describe the utility of ultrasound in determining the need for pre-treatment. Methods Thirty-nine patients with minimally displaced lateral humeral condyle fractures who underwent ultrasound and arthrography examinations before surgery from May 2018 to December 2019 were included in this study. Ultrasound and arthrography predictors of the cartilage hinge status were independently measured. The ultrasound and arthrography results were compared. Results The mean displacement of the fractures was 3.1 mm (range, 2.0~5.0 mm). Arthrography showed incomplete fractures in 24 patients (61.5%) and complete fractures in 15 patients (38.5%). Ultrasound showed incomplete fractures in 25 patients (64.1%) and complete fractures in 14 patients (35.9%). The ultrasound and arthrography results of the integrity of the articular surface were consistent in 92.3% of the cases, including 23 that were predicted to have an intact articular surface and 13 that were predicted to have an incongruity articular surface. There was no correlation between the displacement and the fracture appearing complete on the ultrasound scan. The Pearson coefficient between ultrasound and arthrography for assessing the integrity of the articular surface was 0.837. Conclusions Ultrasound and arthrography assessments of the integrity of the cartilage hinge status appear to be highly consistent. Ultrasound can be used as a complementary tool with arthrography to predict the integrity of the cartilage hinge status in children with minimally displaced lateral humeral condyle fractures. Level of evidence Prospective study; level II.


Molecules ◽  
2021 ◽  
Vol 26 (10) ◽  
pp. 2908
Author(s):  
Kazuo Umemura ◽  
Ryo Hamano ◽  
Hiroaki Komatsu ◽  
Takashi Ikuno ◽  
Eko Siswoyo

Solubilization of carbon nanotubes (CNTs) is a fundamental technique for the use of CNTs and their conjugates as nanodevices and nanobiodevices. In this work, we demonstrate the preparation of CNT suspensions with “green” detergents made from coconuts and bamboo as fundamental research in CNT nanotechnology. Single-walled CNTs (SWNTs) with a few carboxylic acid groups (3–5%) and pristine multi-walled CNTs (MWNTs) were mixed in each detergent solution and sonicated with a bath-type sonicator. The prepared suspensions were characterized using absorbance spectroscopy, scanning electron microscopy, and Raman spectroscopy. Among the eight combinations of CNTs and detergents (two types of CNTs and four detergents, including sodium dodecyl sulfate (SDS) as the standard), SWNTs/MWNTs were well dispersed in all combinations except the combination of the MWNTs and the bamboo detergent. The stability of the suspensions prepared with coconut detergents was better than that prepared with SDS. Because the efficiency of the bamboo detergents against the MWNTs differed significantly from that against the SWNTs, the natural detergent might be useful for separating CNTs. Our results revealed that the use of the “green” detergents had the advantage of dispersing CNTs as well as SDS.


Information ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 278
Author(s):  
Sanlong Jiang ◽  
Shaobo Li ◽  
Qiang Bai ◽  
Jing Yang ◽  
Yanming Miao ◽  
...  

A reasonable grasping strategy is a prerequisite for the successful grasping of a target, and it is also a basic condition for the wide application of robots. Presently, mainstream grippers on the market are divided into two-finger grippers and three-finger grippers. According to human grasping experience, the stability of three-finger grippers is much better than that of two-finger grippers. Therefore, this paper’s focus is on the three-finger grasping strategy generation method based on the DeepLab V3+ algorithm. DeepLab V3+ uses the atrous convolution kernel and the atrous spatial pyramid pooling (ASPP) architecture based on atrous convolution. The atrous convolution kernel can adjust the field-of-view of the filter layer by changing the convolution rate. In addition, ASPP can effectively capture multi-scale information, based on the parallel connection of multiple convolution rates of atrous convolutional layers, so that the model performs better on multi-scale objects. The article innovatively uses the DeepLab V3+ algorithm to generate the grasp strategy of a target and optimizes the atrous convolution parameter values of ASPP. This study used the Cornell Grasp dataset to train and verify the model. At the same time, a smaller and more complex dataset of 60 was produced according to the actual situation. Upon testing, good experimental results were obtained.


2021 ◽  
pp. 1-19
Author(s):  
Habib Ghanbarpourasl

Abstract This paper introduces a power series based method for attitude reconstruction from triad orthogonal strap-down gyros. The method is implemented and validated using quaternions and direction cosine matrix in single and double precision implementation forms. It is supposed that data from gyros are sampled with high frequency and a fitted polynomial is used for an analytical description of the angular velocity vector. The method is compared with the well-known Taylor series approach, and the stability of the coefficients’ norm in higher-order terms for both methods is analysed. It is shown that the norm of quaternions’ derivatives in the Taylor series is bigger than the equivalent terms coefficients in the power series. In the proposed method, more terms can be used in the power series before the saturation of the coefficients and the error of the proposed method is less than that for other methods. The numerical results show that the application of the proposed method with quaternions performs better than other methods. The method is robust with respect to the noise of the sensors and has a low computational load compared with other methods.


Author(s):  
Chuncheng Yang ◽  
Zhong Liu ◽  
Xiangyu Pei ◽  
Cuiling Jin ◽  
Mengchun Yu ◽  
...  

Magnetorheological fluids (MRFs) based on amorphous Fe-Si-B alloy magnetic particles were prepared. The influence of annealing treatment on stability and rheological property of MRFs was investigated. The saturation magnetization ( Ms) of amorphous Fe-Si-B particles after annealing at 550°C is 131.5 emu/g, which is higher than that of amorphous Fe-Si-B particles without annealing. Moreover, the stability of MRF with annealed amorphous Fe-Si-B particles is better than that of MRF without annealed amorphous Fe-Si-B particles. Stearic acid at 3 wt% was added to the MRF2 to enhance the fluid stability to greater than 90%. In addition, the rheological properties demonstrate that the prepared amorphous particle MRF shows relatively strong magnetic responsiveness, especially when the magnetic field strength reaches 365 kA/m. As the magnetic field intensified, the yield stress increased dramatically and followed the Herschel-Bulkley model.


1988 ◽  
Vol 29 (3) ◽  
pp. 367-370
Author(s):  
S. Thönell ◽  
W. Mortensson ◽  
B. Thomasson

2010 ◽  
Vol 163-167 ◽  
pp. 3297-3300 ◽  
Author(s):  
Jia Wei Shi ◽  
Hong Zhu ◽  
Zhi Shen Wu ◽  
Gang Wu

Coupon tests were conducted to investigate the mechanical characteristics of basalt FRP (BFRP) sheet, basalt-carbon hybrid FRP sheets and the corresponding epoxy rein under the effect of freeze-thaw cycling. FRP sheets and epoxy rein coupons were subjected to up to 200 and 250 freeze-thaw cycles respectively. Test parameters included the number of freeze-thaw cycles and the types of FRP composites. Test results show that (1) BFRP sheet perform better than CFRP or GFRP sheets under high freeze-thaw cycles; (2) exposed hybrid FRP sheets not only show very little loss in mechanical properties, but also contribute to the stability of test data; (3) mechanical properties of rein epoxy decrease significantly with increasing freeze-thaw cycles.


Sign in / Sign up

Export Citation Format

Share Document