scholarly journals A robust model-free controller for a three-phase grid-connected photovoltaic system based on ultra-local model

Author(s):  
Ahsene Boubakir ◽  
Sid-Ahmed Touil ◽  
Salim Labiod ◽  
Nasserdine Boudjerda

AbstractIn this paper, a robust model-free controller for a grid-connected photovoltaic (PV) system is designed. The system consists of a PV generator connected to a three-phase grid by a DC/AC converter. The control objectives of the overall system are to extract maximum power from the PV source, to control reactive power exchange and to improve the quality of the current injected into the grid. The model-free control technique is based on the use of an ultra-local model instead of the dynamic model of the overall system. The local model is continuously updated based on a numerical differentiator using only the input–output behavior of the controlled system. The model-free controller consists of a classical feedback controller and a compensator for the effects of internal parameter changes and external disturbances. Simulation results illustrate the efficiency of the controller for grid-connected PV systems.

Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2899 ◽  
Author(s):  
Alexis B. Rey-Boué ◽  
N. F. Guerrero-Rodríguez ◽  
Johannes Stöckl ◽  
Thomas I. Strasser

This article deals with the vector control in dq axes of a three-phase grid-connected photovoltaic system with single-stage topology and low-voltage-ride-through capability. The photovoltaic generator is built using an array of several series-parallel Suntech PV modules and is modeled as a Lookup Table (two-dimensional; 2-D). The requirements adopted when grid voltage sags occur are based in both the IEC 61400-21 European normative and the allowed amount of reactive power to be delivered according to the Spanish grid code, which avoids the disconnection of the inverter under grid faults by a limitation in the magnitude of the three-phase output inverter currents. For this, the calculation of the positive- and negative-sequences of the grid voltages is made and a conventional three-phase Phase-Locked Loop is used for the inverter-grid synchronization, allowing the control of the active and reactive powers solely with the dq components of the inverter currents. A detailed enhanced flowchart of the control algorithm with low-voltage-ride-through capability is presented and several simulations and experiments using Matlab/SIMULINK and the Controller Hardware-in-the-Loop simulation technique, respectively, are run for several types of one- and three-phase voltage sags in order to validate its behavior.


Energies ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3773
Author(s):  
Kamran Zeb ◽  
Tiago Davi Curi Busarello ◽  
Saif Ul Islam ◽  
Waqar Uddin ◽  
Kummara Venkata Guru Raghavendra ◽  
...  

The novelty behind the research in this paper is to investigate the Super Twisting Sliding Mode Controller (ST-SMC) for efficiently injecting both active and reactive power under normal and abnormal operating conditions for a three-phase grid-connected photovoltaic (PV) system. The ST-SMC is aimed to inject sinusoidal current to the grid with low Total Harmonic Distortion (THD), to avoid chattering with easy real implementation, and to enhance the quality of disturbance rejection and sensitivity to parameter variation. The test under normal conditions includes initialization, steady state behavior, dynamic behavior, and interrupting the injection of acting and reactive power while the abnormal conditions consists of voltage sag, voltage swell, frequency variation, DC-link variation, and inclusion of 5th harmonics, etc. The phase lock loop used for synchronization is based on a synchronous reference frame that works well under distorted grids and nonideal. Automatic code is generated in PSIM 9.1 for hardware implementation in the DSP board TMS32F28335 from Texas Instruments while code composer studio 6.2.0 is used for debugging. The real time testing is executed using Typhoon Hardware in Loop (HIL) 402 device on the DSP board. The results authenticate the fastness, effectiveness, and robustness for both steady state and dynamic behavior under various scenarios of the designed controller.


2019 ◽  
Vol 20 (1) ◽  
pp. 140-157
Author(s):  
N Hemalatha ◽  
Seyezhai Ramalingam

A grid-tied, single stage, three phase, PV system provides higher efficiency than a two-stage PV system. This paper presents a three-phase, single stage, grid-connected PV system with MPPT and reactive power injection capability into the grid using modified capacitor assisted extended boost quasi Z-source inverter (MCAEB q-ZSI) as the grid-tied PV inverter. The adaptability of the inverter for irradiance changes and the boost factor control with its shoot-through duty ratio adjustment made it highly recommended for the grid system. The shoot-through control technique like maximum constant boost control with a third harmonic injection enhances the performance of the inverter by reducing the low order ripples and voltage stress. The fuzzy voltage controller is proposed with the capacitor linearization algorithm to regulate the DC-link voltage. The current approach uses a fuzzy controller to control the real and the reactive power injection into the grid. The performance evaluation of the fuzzy and PI grid controller is carried out for the constant irradiance condition and from the investigation, parameters like boost factor (B), the shoot-through duty ratio(Ds), real power (P), reactive power (Q),  power factor and harmonics in the current injection are determined. A laboratory setup of the PV powered grid system is implemented, tested and validated with the simulation results. ABSTRAK: Dalam sistem fotovoltaik (PV) yang bersambung dengan satu peringkat, satu sistem elektronik kuasa yang mempunyai keuntungan dan kecekapan yang tinggi diperlukan untuk menginterupasi dengan utiliti tersebut. Dalam makalah ini, kapasitor yang diubah suai dibantu oleh pemacu kuadratik Z-source yang dilanjutkan (MCAEB q-ZSI) bertindak sebagai unit interfacing antara PV dan grid. Penyesuaian penyongsang untuk perubahan sinaran dan kawalan faktor rangsangan dengan pelarasan nisbah tugas menembak membuatnya sangat disyorkan untuk sistem grid. Teknik kawalan menembak seperti kawalan rangsangan berterusan maksimum dengan suntikan harmonik ketiga meningkatkan prestasi penyongsang dengan mengurangkan aruhan pesanan rendah dan tekanan voltan. Pendekatan semasa menggunakan pengawal kabur untuk mengawal suntikan kuasa sebenar dan reaktif ke grid. Penilaian prestasi pengawal grid fuzzy dan PI dilakukan untuk keadaan iradiasi malar dan dari penyiasatan, parameter seperti faktor rangsangan (B), nisbah tugas menembak (Ds), kuasa nyata (P), kuasa reaktif Q), faktor kuasa dan harmonik dalam suntikan semasa ditentukan.   


Author(s):  
Salma Zouga ◽  
Mohamed Benchagra ◽  
Abdallah Ailane

This article presents a robust non-linear control technique of the three-phase photovoltaic system. The structure chosen for this PV system is that of two power converters and DC voltage intermediate bus. The two power converters are: the DC-DC converter and the three-phase inverter, which requires two main controllers. These controllers have three main objectives. The first objective is to impose the PV voltage generated by the photovoltaic panel, in order to follow a maximum reference voltage provided by the MPPT block. The second one is to maintain the DC link voltage to a constant value, in order to optimize the transfer of energy between the two power converters. The last objective is to inject a three-phase sinusoidal current into the grid, while respecting a unit power factor. With the intention to achieve these three objectives, we designed cascading nonlinear controllers by using the technique of non-linear backstepping control in the synthesis of these two controllers, based on the Lyapunov function, with regard to maximise the PVG output voltage, in order to have a unitary power factor at the grid side. In order to regulate DC-link voltage, we developed an integral proportional controller (PI) with parameters that are optimized by the Particle Swarm Optimization (PSO) method. The robustness of the controller designed approach is tested by a simulation in MATLAB/Simulink software, that improves the performances of each controller whatever conditions of climate.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Mohannad Jabbar Mnati ◽  
Dimitar V. Bozalakov ◽  
Alex Van den Bossche

Nowadays, most three-phase, “off the shelf” inverters use electrolytic capacitors at the DC bus to provide short term energy storage. However, this has a direct impact on inverter lifetime and the total cost of the photovoltaic system. This article proposes a novel control strategy called a 120° bus clamped PWM (120BCM). The 120BCM modulates the DC bus and uses a smaller DC bus capacitor value, which is typical for film capacitors. Hence, the inverter lifetime can be increased up to the operational lifetime of the photovoltaic panels. Thus, the total cost of ownership of the PV system will decrease significantly. Furthermore, the proposed 120BCM control strategy modulates only one phase current at a time by using only one leg to perform the modulation. As a result, switching losses are significantly reduced. The full system setup is designed and presented in this paper with some practical results.


A reliable grid connected Photovoltaic (PV) system require effective control schemes for efficient use of solar energy. This paper presents a three-phase grid tied PV system with decoupled real and reactive power control to achieve desired power factor with Maximum Power Point Tracking (MPPT) controller to get maximum solar energy. The synchronous reference frame (dq) control along with decoupling concept is used to control the DC-AC inverter output, while the Phase Locked Loop (PLL) synchronization technique is used to monitor and synchronize the voltage and current at the grid side. The DC-DC converter with Incremental Conductance (InC) based MPPT model is also designed in this paper due to better accuracy compared to Perturb & Observe (P&O) algorithm. The simulation is performed in MATLAB/SIMULINK and a 31.5 kW PV system is modelled to get 30 kW power with the help of MPPT at Standard Test Conditions (STC). Any power factor value between 0.85 lagging to 0.9 leading can be obtained by changingreference q current in this inverter control strategy. The simulation results show that the change of reactive powerdoes not affecttheactive power values of the system, which verifies the effectiveness of the decoupled control strategy of the inverter.


2018 ◽  
Vol 18 (1) ◽  
pp. 35 ◽  
Author(s):  
Rofiatul Izah ◽  
Subiyanto Subiyanto ◽  
Dhidik Prastiyanto

Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.


Author(s):  
Mohammad Rustam M. L. ◽  
F. Danang Wijaya

Under various external conditions, grid connected PV system performance is strongly affected by the topology that is used to connect a PV system with grid. This research aims to design a multistring based converter topology for three-phase grid connected 200 kW PV system that has a high performance in various operating conditions. Research was done by a simulation method using Matlab-Simulink with performance being evaluated including the generated power, efficiency, power quality in accordance with grid requirements, as well as the power flow. In the simulation, multistring converter topology was designed using two dc-dc boost multistring converters connected in parallel to a centralized of three-phase three-level NPC inverter with the size of the string being shorter and more parallel strings as well as the maximum voltage of the PV array of 273.5 V close to dc voltage reference of 500 V. Each dc-dc boost multistring converter have individual MPPT controllers. The simulation results showed that this multistring converter topology had a high performance in various operating conditions. This due to more power generated by the NPC inverter (> 190 kW) at the time of high power generation on the STC conditions (1000 W/m2, 25 oC), the lowest efficiency of the total system is 95.08 % and the highest efficiency of the total system is 99.4 %, the quality of the power generated in accordance with the requirements of grid, as well as the inverter put more active power to the grid and less reactive power to the grid. The response of the inverter slightly worse for loads with greater reactive power and unbalanced.