scholarly journals Rapid and sensitive point-of-care detection of Leptospira by RPA-CRISPR/Cas12a targeting lipL32

2022 ◽  
Vol 16 (1) ◽  
pp. e0010112
Author(s):  
Sirawit Jirawannaporn ◽  
Umaporn Limothai ◽  
Sasipha Tachaboon ◽  
Janejira Dinhuzen ◽  
Patcharakorn Kiatamornrak ◽  
...  

Background One of the key barriers preventing rapid diagnosis of leptospirosis is the lack of available sensitive point-of-care testing. This study aimed to develop and validate a clustered regularly-interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein 12a (CRISPR/Cas12a) platform combined with isothermal amplification to detect leptospires from extracted patient DNA samples. Methodology/Principal findings A Recombinase Polymerase Amplification (RPA)-CRISPR/Cas12a-fluorescence assay was designed to detect the lipL32 gene of pathogenic Leptospira spp. The assays demonstrated a limit of detection (LOD) of 100 cells/mL, with no cross-reactivity against several other acute febrile illnesses. The clinical performance of the assay was validated with DNA extracted from 110 clinical specimens and then compared to results from qPCR detection of Leptospira spp. The RPA-CRISPR/Cas12a assay showed 85.2% sensitivity, 100% specificity, and 92.7% accuracy. The sensitivity increased on days 4–6 after the fever onset and decreased after day 7. The specificity was consistent for several days after the onset of fever. The overall performance of the RPA-CRISPR/Cas12a platform was better than the commercial rapid diagnostic test (RDT). We also developed a lateral flow detection assay (LFDA) combined with RPA-CRISPR/Cas12a to make the test more accessible and easier to interpret. The combined LFDA showed a similar LOD of 100 cells/mL and could correctly distinguish between known positive and negative clinical samples in a pilot study. Conclusions/Significance The RPA-CRISPR/Cas12 targeting the lipL32 gene demonstrated acceptable sensitivity and excellent specificity for detection of leptospires. This assay might be an appropriate test for acute leptospirosis screening in limited-resource settings.

Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3351
Author(s):  
Sara Viveiros ◽  
Mónica Rodrigues ◽  
Débora Albuquerque ◽  
Sofia A. M. Martins ◽  
Susana Cardoso ◽  
...  

The accurate diagnosis of bacterial infections is of critical importance for effective treatment decisions. Due to the multietiologic nature of most infectious diseases, multiplex assays are essential for diagnostics. However, multiplexability in nucleic acid amplification-based methods commonly resorts to multiple primers and/or multiple reaction chambers, which increases analysis cost and complexity. Herein, a polymerase chain reaction (PCR) offer method based on a universal pair of primers and an array of specific oligonucleotide probes was developed through the analysis of the bacterial 16S ribosomal RNA gene. The detection system consisted of DNA hybridization over an array of magnetoresistive sensors in a microfabricated biochip coupled to an electronic reader. Immobilized probes interrogated single-stranded biotinylated amplicons and were obtained using asymmetric PCR. Moreover, they were magnetically labelled with streptavidin-coated superparamagnetic nanoparticles. The benchmarking of the system was demonstrated to detect five major bovine mastitis-causing pathogens: Escherichia coli, Klebsiella sp., Staphylococcus aureus, Streptococcus uberis, and Streptococcus agalactiae. All selected probes proved to specifically detect their respective amplicon without significant cross reactivity. A calibration curve was performed for S. agalactiae, which demonstrates demonstrating a limit of detection below 30 fg/µL. Thus, a sensitive and specific multiplex detection assay was established, demonstrating its potential as a bioanalytical device for point-of-care applications.


Diagnosis ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Gian Luca Salvagno ◽  
Gianluca Gianfilippi ◽  
Damiano Bragantini ◽  
Brandon M. Henry ◽  
Giuseppe Lippi

Abstract Objectives Novel point-of-care antigen assays present a promising opportunity for rapid screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. The purpose of this study was the clinical assessment of the new Roche SARS-CoV-2 Rapid Antigen Test. Methods The clinical performance of Roche SARS-CoV-2 Rapid Antigen Test was evaluated vs. a reverse transcription polymerase chain reaction (RT-PCR) laboratory-based assay (Seegene AllplexTM2019-nCoV) in nasopharyngeal swabs collected from a series of consecutive patients referred for SARS-CoV-2 diagnostics to the Pederzoli Hospital (Peschiera del Garda, Verona, Italy) over a 2-week period. Results The final study population consisted of 321 consecutive patients (mean age, 46 years and IQR, 32–56 years; 181 women, 56.4%), with 149/321 (46.4%) positive for SARS-CoV-2 RNA via the Seegene AllplexTM2019-nCoV Assay, and 109/321 (34.0%) positive with Roche SARS-CoV-2 Rapid Antigen Test, respectively. The overall accuracy of Roche SARS-CoV-2 Rapid Antigen Test compared to molecular testing was 86.9%, with 72.5% sensitivity and 99.4% specificity. Progressive decline in performance was observed as cycle threshold (Ct) values of different SARS-CoV-2 gene targets increased. The sensitivity was found to range between 97–100% in clinical samples with Ct values <25, between 50–81% in those with Ct values between 25 and <30, but low as 12–18% in samples with Ct values between 30 and <37. Conclusions The clinical performance of Roche SARS-CoV-2 Rapid Antigen Test is excellent in nasopharyngeal swabs with Ct values <25, which makes it a reliable screening test in patients with high viral load. However, mass community screening would require the use of more sensitive techniques.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shan Wei ◽  
Esther Kohl ◽  
Alexandre Djandji ◽  
Stephanie Morgan ◽  
Susan Whittier ◽  
...  

AbstractThe COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/μl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chukwunonso Onyilagha ◽  
Henna Mistry ◽  
Peter Marszal ◽  
Mathieu Pinette ◽  
Darwyn Kobasa ◽  
...  

AbstractThe coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), calls for prompt and accurate diagnosis and rapid turnaround time for test results to limit transmission. Here, we evaluated two independent molecular assays, the Biomeme SARS-CoV-2 test, and the Precision Biomonitoring TripleLock SARS-CoV-2 test on a field-deployable point-of-care real-time PCR instrument, Franklin three9, in combination with Biomeme M1 Sample Prep Cartridge Kit for RNA 2.0 (M1) manual extraction system for rapid, specific, and sensitive detection of SARS-COV-2 in cell culture, human, and animal clinical samples. The Biomeme SARS-CoV-2 assay, which simultaneously detects two viral targets, the orf1ab and S genes, and the Precision Biomonitoring TripleLock SARS-CoV-2 assay that targets the 5′ untranslated region (5′ UTR) and the envelope (E) gene of SARS-CoV-2 were highly sensitive and detected as low as 15 SARS-CoV-2 genome copies per reaction. In addition, the two assays were specific and showed no cross-reactivity with Middle Eastern respiratory syndrome coronavirus (MERS-CoV), infectious bronchitis virus (IBV), porcine epidemic diarrhea virus (PEDV), transmissible gastroenteritis (TGE) virus, and other common human respiratory viruses and bacterial pathogens. Also, both assays were highly reproducible across different operators and instruments. When used to test animal samples, both assays equally detected SARS-CoV-2 genetic materials in the swabs from SARS-CoV-2-infected hamsters. The M1 lysis buffer completely inactivated SARS-CoV-2 within 10 min at room temperature enabling safe handling of clinical samples. Collectively, these results show that the Biomeme and Precision Biomonitoring TripleLock SARS-CoV-2 mobile testing platforms could reliably and promptly detect SARS-CoV-2 in both human and animal clinical samples in approximately an hour and can be used in remote areas or health care settings not traditionally serviced by a microbiology laboratory.


2020 ◽  
Author(s):  
Uroš Zupančič ◽  
Pawan Jolly ◽  
Pedro Estrela ◽  
Despina Moschou ◽  
Donald E. Ingber

ABSTRACTSepsis is a leading cause of mortality worldwide that is difficult to diagnose and manage because this requires simultaneous analysis of multiple biomarkers. Electrochemical detection methods could potentially provide a way to accurately quantify multiple sepsis biomarkers in a multiplexed manner as they have very low limits of detection and require minimal sensor instrumentation; however, affinity-based electrochemical sensors are usually hampered by biological fouling. Here we describe development of an electrochemical detection platform that enables detection of multiple sepsis biomarkers simultaneously by incorporating a recently developed nanocomposite coating composed of crosslinked bovine serum albumin containing a network of reduced graphene oxide nanoparticles that prevents biofouling. Using nanocomposite coated planar gold electrodes, we constructed a procalcitonin sensor and demonstrated sensitive PCT detection in undiluted serum and clinical samples, as well as excellent correlation with a conventional ELISA (adjusted r2 = 0.95). Sensors for two additional sepsis biomarkers — C-reactive protein and pathogen-associated molecular patterns — were developed on the same multiplexed platform and tested in whole blood. Due to the excellent antifouling properties of the nanocomposite coating, all three sensors exhibited specific responses within the clinically significant range without any cross-reactivity in the same channel with low sample volume. This platform enables sensitive simultaneous electrochemical detection of multiple analytes in human whole blood, which can be expanded further to any target analyte with an appropriate antibody pair or capturing probe, and thus, may offer a potentially valuable tool for development of clinical point-of-care diagnostics.GRAPHICAL ABSTRACT


2019 ◽  
Vol 4 (Suppl 3) ◽  
pp. A2.1-A2
Author(s):  
Michael Frimpong ◽  
Hubert Ahor ◽  
Francisca Sarpong ◽  
Ken Laing ◽  
Mark Wansbrough-Jones ◽  
...  

BackgroundThere are no primary measures to prevent people from contracting Buruli ulcer, mainly due to poor understanding of its epidemiology. The current control strategy emphasises early diagnosis and prompt treatment, with the goal of avoiding the complications associated with advanced stages of the disease. There is no diagnostic test for the disease appropriate for use at the primary health care level where most cases are detected and treated. Diagnosis based on clinical signs is unreliable in inexperienced hands and complicated by infections that have similar presentations. This study was to develop and evaluate the use of recombinase polymerase amplification (RPA) assay for the detection of Mycobacterium ulcerans at the point of patient care.MethodsA specific fragment of IS2404 of M. ulcerans was amplified in 15 min at a constant temperature of 42°C, using the RPA assay and analysed on a portable fluorometre. The’method was tested for sensitivity and specificity with molecular standard of IS2404 DNA fragment, various M.’ulcerans strains, other mycobacteria and environmentally associated bacteria. Additionally, the assay performance as a diagnostic tool was tested with archived DNA from symptomatic patients. All results were compared with that of a highly sensitive IS2404 PCR.ResultsThe detection limit was 50 copies of IS2404 in 15 min using plasmid standard and 125 fg with genomic Mu DNA equivalent 25 genomic copies. The assay was highly specific in detecting all strains of M. ulcerans with no observed cross reactivity with other mycobacteria and common skin colonising bacteria. The clinical sensitivity and specificity of the BU-RPA assay using clinical samples was 86% and 100% respectively.ConclusionWe have developed a real-time isothermal RPA assay for the detection of M. ulcerans as a cheaper alternative to PCR. Combining this assay with a simple extraction protocol will maximise its use as point-of-care test for Buruli ulcer.


Biosensors ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 293
Author(s):  
Paola Cecere ◽  
Francesca Gatto ◽  
Claudia Cortimiglia ◽  
Daniela Bassi ◽  
Franco Lucchini ◽  
...  

Clostridium tyrobutyricum represents the main spoiling agent responsible for late blowing defects (LBD) in hard and semi-hard cheeses. Its spores are resistant to manufacturing procedures and can germinate during the long ripening process, causing the burst of the cheese paste with a consequent undesirable taste. The lower quality of blown cheeses leads to considerable financial losses for the producers. The early identification of spore contaminations in raw milk samples thus assumes a pivotal role in industrial quality control. Herein, we developed a point of care (POC) testing method for the sensitive detection of C. tyrobutyricum in milk samples, combining fast DNA extraction (with no purification steps) with a robust colorimetric loop-mediated isothermal amplification (LAMP) technique. Our approach allows for the sensitive and specific detection of C. tyrobutyricum spores (limit of detection, LoD: ~2 spores/mL), with the advantage of a clear naked-eye visualization of the results and a potential semi-quantitative discrimination of the contamination level. In addition, we demonstrated the feasibility of this strategy using a portable battery-operated device that allowed both DNA extraction and amplification steps, proving its potential for on-site quality control applications without the requirement of sophisticated instrumentation and trained personnel.


Author(s):  
Puck B. van Kasteren ◽  
Bas van der Veer ◽  
Sharon van den Brink ◽  
Lisa Wijsman ◽  
Jørgen de Jonge ◽  
...  

ABSTRACTThe final months of 2019 witnessed the emergence of a novel coronavirus in the human population. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has since spread across the globe and is posing a major burden on society. Measures taken to reduce its spread critically depend on timely and accurate identification of virus-infected individuals by the most sensitive and specific method available, i.e. real-time reverse transcriptase PCR (RT-PCR). Many commercial kits have recently become available, but their performance has not yet been independently assessed.The aim of this study was to compare basic analytical and clinical performance of selected RT-PCR kits from seven different manufacturers (Altona Diagnostics, BGI, CerTest Biotec, KH Medical, PrimerDesign, R-Biopharm AG, and Seegene).We used serial dilutions of viral RNA to establish PCR efficiency and estimate the 95% limit of detection (LOD95%). Furthermore, we ran a panel of SARS-CoV-2-positive clinical samples (n=16) for a preliminary evaluation of clinical sensitivity. Finally, we used clinical samples positive for non-coronavirus respiratory viral infections (n=6) and a panel of RNA from related human coronaviruses to evaluate assay specificity.PCR efficiency was ≥96% for all assays and the estimated LOD95% varied within a 6-fold range. Using clinical samples, we observed some variations in detection rate between kits. Importantly, none of the assays showed cross-reactivity with other respiratory (corona)viruses, except as expected for the SARS-CoV-1 E-gene.We conclude that all RT-PCR kits assessed in this study may be used for routine diagnostics of COVID-19 in patients by experienced molecular diagnostic laboratories.


Author(s):  
Sonny M Assennato ◽  
Allyson V Ritchie ◽  
Cesar Nadala ◽  
Neha Goel ◽  
Hongyi Zhang ◽  
...  

AbstractNucleic acid amplification for the detection of SARS-CoV-2 RNA in respiratory samples is the standard method for diagnosis. These tests are centralised and therefore turnaround times can be 2-5 days. Point-of-care testing with rapid turnaround times would allow more effective triage in settings where patient management and infection control decisions need to be made rapidly.Inclusivity and specificity of the SAMBA II SARS-CoV-2 assay was determined by in silico analyses of the primers and probes. Analytical and clinical sensitivity and specificity of the SAMBA II SARS-CoV-2 Test was evaluated for analytical sensitivity and specificity. Clinical performance was evaluated in residual clinical samples compared to the Public Health England reference tests.The limit of detection of the SAMBA II SARS-CoV-2 Test is 250 cp/mL and is specific for detection of 2 regions of the SARS-CoV-2 genome. The clinical sensitivity was evaluated in 172 clinical samples provided by the Clinical Microbiology and Public Health Laboratory, Addenbrooke’s Hospital, Cambridge (CMPHL), which showed a sensitivity of 98.9% (95% CI 94.03-99.97%), specificity of 100% (95% CI 95.55-100%), PPV of 100% and NPV of 98.78% (92.02-99.82%) compared to testing by CMPHLSAMBA detected 3 positive samples that were initially negative by PHE Test. The data shows that the SAMBA II SARS-CoV-2 Test performs equivalently to the centralised testing methods with a much quicker turnaround time. Point of care testing, such as SAMBA, should enable rapid patient management and effective implementation of infection control measures.


Author(s):  
Abu Naser Mohon ◽  
Jana Hundt ◽  
Guido van Marle ◽  
Kanti Pabbaraju ◽  
Byron Berenger ◽  
...  

AbstractWe have developed a reverse-transcriptase loop mediated amplification (RT-LAMP) method targeting genes encoding the Spike (S) protein and RNA-dependent RNA polymerase (RdRP) of SARS-CoV-2. The LAMP assay achieves comparable limit of detection as commonly used RT-PCR protocols based on artificial targets, recombinant Sindbis virus, and clinical samples. Clinical validation of single-target (S gene) LAMP (N=120) showed a positive percent agreement (PPA) of 41/42 (97.62%) and negative percent agreement (NPA) of 77/78 (98.72%) compared to reference RT-PCR. Dual-target RT-LAMP (S and RdRP gene) achieved a PPA of 44/48 (91.97%) and NPA 72/72 (100%) when including discrepant samples. The assay can be performed without a formal extraction procedure, with lyophilized reagents which do need cold chain, and is amenable to point-of-care application with visual detection.


Sign in / Sign up

Export Citation Format

Share Document