scholarly journals The evaluation of the utility of the GENECUBE HQ SARS-CoV-2 for anterior nasal samples and saliva samples with a new rapid examination protocol

PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0262159
Author(s):  
Asami Naito ◽  
Yoshihiko Kiyasu ◽  
Yusaku Akashi ◽  
Akio Sugiyama ◽  
Masashi Michibuchi ◽  
...  

Introduction GENECUBE® is a rapid molecular identification system, and previous studies demonstrated that GENECUBE® HQ SARS-CoV-2 showed excellent analytical performance for the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) with nasopharyngeal samples. However, other respiratory samples have not been evaluated. Methods This prospective comparison between GENECUBE® HQ SARS-CoV-2 and reference real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for the detection of SARS-CoV-2 using anterior nasal samples and saliva samples. Additionally, we evaluated a new rapid examination protocol using GENECUBE® HQ SARS-CoV-2 for the detection of SARS-CoV-2 with saliva samples. For the rapid protocol, in the preparation of saliva samples, purification and extraction processes were adjusted, and the total process time was shortened to approximately 35 minutes. Results For 359 anterior nasal samples, the total-, positive-, and negative concordance of the two assays was 99.7% (358/359), 98.1% (51/52), and 100% (307/307), respectively. For saliva samples, the total-, positive-, and negative concordance of the two assays was 99.6% (239/240), 100% (56/56), and 99.5% (183/184), respectively. With the new protocol, total-, positive-, and negative concordance of the two assays was 98.8% (237/240), 100% (56/56), and 98.4% (181/184), respectively. In all discordance cases, SARS-CoV-2 was detected by additional molecular examinations. Conclusion GENECUBE® HQ SARS-CoV-2 provided high analytical performance for the detection of SARS-CoV-2 in anterior nasal samples and saliva samples.

2021 ◽  
Author(s):  
Asami Naito ◽  
Yoshihiko Kiyasu ◽  
Yusaku Akashi ◽  
Akio Sugiyama ◽  
Masashi Michibuchi ◽  
...  

AbstractIntroductionGENECUBE® is a rapid molecular identification system, and previous studies demonstrated that GENECUBE® HQ SARS-CoV-2 showed excellent analytical performance for the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) with nasopharyngeal samples. However, other respiratory samples have not been evaluated.MethodsThis prospective comparison between GENECUBE® HQ SARS-CoV-2 and reference real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for the detection of SARS-CoV-2 using anterior nasal samples and saliva samples. Additionally, we evaluated a new rapid examination protocol using GENECUBE® HQ SARS-CoV-2 for the detection of SARS-CoV-2 with saliva samples. For the rapid protocol, in the preparation of saliva samples, purification and extraction processes were adjusted, and the total process time was shortened to approximately 35 minutes.ResultsFor 359 anterior nasal samples, the total-, positive-, and negative concordance of the two assays was 99.7% (358/359), 98.1% (51/52), and 100% (307/307), respectively. For saliva samples, the total-, positive-, and negative concordance of the two assays was 99.6% (239/240), 100% (56/56), and 99.5% (183/184), respectively. With the new protocol, total-, positive-, and negative concordance of the two assays was 98.8% (237/240), 100% (56/56), and 98.4% (181/184), respectively. In all discordance cases, SARS-CoV-2 was detected by additional molecular examinations.ConclusionGENECUBE® HQ SARS-CoV-2 provided high analytical performance for the detection of SARS-CoV-2 in anterior nasal samples and saliva samples.


2006 ◽  
Vol 175 (4S) ◽  
pp. 485-486
Author(s):  
Sabarinath B. Nair ◽  
Christodoulos Pipinikas ◽  
Roger Kirby ◽  
Nick Carter ◽  
Christiane Fenske

1993 ◽  
Vol 70 (03) ◽  
pp. 500-505 ◽  
Author(s):  
B Wyler ◽  
L Daviet ◽  
H Bortkiewicz ◽  
J-C Bordet ◽  
J L McGregor

SummaryGlycoprotein CD36, also known as GPIIIb or GPIV, is a major platelet glycoprotein that bears the newly identified Naka alloantigen. The aim of this study was to clone platelet CD36 and investigate other forms of CD36-cDNA present in monocytes, endothelial and HEL cells. RNA from above mentioned cells were reverse transcribed (RT), using specific primers for CD36, and amplified by the polymerase chain reaction (PCR) technique. Sequencing the different amplified platelet derived cDNA fragments, spanning the whole coding and flanking regions, showed the near identity between platelet and CD36-placenta cDNA. Platelet CD36-cDNA cross-hybridized, in Southern blots, with RT-PCR amplified cDNA originating from monocytes, endothelial and HEL cells. However, monocytes showed a RT-PCR amplified cDNA fragment (561 bp) that was present in platelets and placenta but not on endothelial on HEL-cells. Northern blot analysis of platelet RNA hybridized with placenta CD36 indicated the presence of a major (1.95 kb) and a minor (0.95 kb) transcript. The 1.95 kb transcript was the only one observed on Northern blots of monocytes, endothelial and HEL cells. These results indicate that the structure of CD36 expressed in platelets is similar, with the exception of the 3’ flanking region, to that of placenta. Differences in apparent molecular weight between CD36 and CD36-like glycoproteins may be due to post-translational modifications.


1994 ◽  
Vol 72 (05) ◽  
pp. 762-769 ◽  
Author(s):  
Toshiro Takafuta ◽  
Kingo Fujirmura ◽  
Hironori Kawano ◽  
Masaaki Noda ◽  
Tetsuro Fujimoto ◽  
...  

SummaryGlycoprotein V (GPV) is a platelet membrane protein with a molecular weight of 82 kD, and one of the leucine rich glycoproteins (LRG). By reverse transcription-polymerase chain reaction (RT-PCR), GPV cDNA was amplified from mRNA of platelets and megakaryocytic cell lines. However, since there are few reports indicating whether GPV protein is expressed in megakaryocytes as a lineage and maturation specific protein, we studied the GPV expression at the protein level by using a novel monoclonal antibody (1D9) recognizing GPV. Flow cytometric and immunohistochemical analysis indicated that GPV was detected on the surface and in the cytoplasm of only the megakaryocytes in bone marrow aspirates. In a megakaryocytic cell line UT-7, GPV antigen increased after treatment with phorbol-12-myri-state-13-acetate (PMA). These data indicate that only megakaryocytes specifically express the GPV protein among hematopoietic cells and that the expression of GPV increases with differentiation of the megakaryocyte as GPIb-IX complex.


1995 ◽  
Vol 31 (5-6) ◽  
pp. 371-374 ◽  
Author(s):  
R. Gajardo ◽  
R. M. Pintó ◽  
A. Bosch

A reverse transcription polymerase chain reaction (RT-PCR) assay is described that has been developed for the detection and serotyping of group A rotavirus in stool specimens and concentrated and non-concentrated sewage specimens.


2020 ◽  
pp. 175717742097679
Author(s):  
Kordo Saeed ◽  
Emanuela Pelosi ◽  
Nitin Mahobia ◽  
Nicola White ◽  
Christopher Labdon ◽  
...  

Background: We report an outbreak of SARS coronavirus-2 (SARS-CoV-2) infection among healthcare workers (HCW) in an NHS elective healthcare facility. Methodology: A narrative chronological account of events after declaring an outbreak of SARS-CoV-2 among HCWs. As part of the investigations, HCWs were offered testing during the outbreak. These were: (1) screening by real-time reverse transcriptase polymerase chain reaction (RT- PCR) to detect a current infection; and (2) serum samples to determine seroprevalence. Results: Over 180 HCWs were tested by real-time RT-PCR for SARS-CoV-2 infection. The rate of infection was 15.2% (23.7% for clinical or directly patient-facing HCWs vs. 4.8% in non-clinical non-patient-facing HCWs). Of the infected HCWs, 57% were asymptomatic. Seroprevalence (SARS-CoV-2 IgG) among HCWs was 13%. It was challenging to establish an exact source for the outbreak. The importance of education, training, social distancing and infection prevention practices were emphasised. Additionally, avoidance of unnecessary transfer of patients and minimising cross-site working for staff and early escalation were highlighted. Establishing mass and regular screening for HCWs are also crucial to enabling the best care for patients while maintaining the wellbeing of staff. Conclusion: To our knowledge, this is the first UK outbreak report among HCWs and we hope to have highlighted some key issues and learnings that can be considered by other NHS staff and HCWs globally when dealing with such a task in future.


2020 ◽  
Author(s):  
Thomas Tschoellitsch ◽  
Martin Dünser ◽  
Carl Böck ◽  
Karin Schwarzbauer ◽  
Jens Meier

Abstract Objective The diagnosis of COVID-19 is based on the detection of SARS-CoV-2 in respiratory secretions, blood, or stool. Currently, reverse transcription polymerase chain reaction (RT-PCR) is the most commonly used method to test for SARS-CoV-2. Methods In this retrospective cohort analysis, we evaluated whether machine learning could exclude SARS-CoV-2 infection using routinely available laboratory values. A Random Forests algorithm with 1353 unique features was trained to predict the RT-PCR results. Results Out of 12,848 patients undergoing SARS-CoV-2 testing, routine blood tests were simultaneously performed in 1528 patients. The machine learning model could predict SARS-CoV-2 test results with an accuracy of 86% and an area under the receiver operating characteristic curve of 0.90. Conclusion Machine learning methods can reliably predict a negative SARS-CoV-2 RT-PCR test result using standard blood tests.


2021 ◽  
Vol 104 (2) ◽  
pp. 003685042110261
Author(s):  
Sungwoo Choi ◽  
Hyo Jeong Choi ◽  
Ho Jung Kim

The most common method for SARS-CoV-2 testing is throat or nasal swabbing by real-time reverse transcription polymerase chain reaction (RT-PCR) assay. In South Korea, drive-through swab test is used for screening system and community treatment centers (CTCs), which admit and treat confirmed COVID-19 patients with mild symptoms, are being used. This retrospective study was conducted on patients admitted to a CTC on March 6, 2020. A total of 313 patients were admitted. The nasal and throat swabs were collected from the upper respiratory tract, and a sputum test was performed to obtain lower respiratory samples. The positive rate of the first set of test, sputum test was higher than that of the swab test ( p = 0.011). In the second set of test, 1 week after the first ones, the rate of positive swab tests was relatively high ( p = 0.026). In the first set of test, 66 of 152 (43.4%) patients showed 24-h consecutive negative swab test results, when the sputum test results were considered together, that number fell to 29 patients (19.1%) ( p < 0.001). Also, in the second set of test, 63 of 164 (38.4%) patients met the discharge criteria only when the swab test was considered; that number fell to 30 (18.3%) when the sputum test results were also considered ( p < 0.001). Using the swab test alone is insufficient for screening test and discharge decision. Patients who may have positive result in the sputum test can be missed.


2021 ◽  
Vol 11 (02) ◽  
pp. e80-e83
Author(s):  
Benjamin R. Harding ◽  
Farha Vora

AbstractWe present a case of a term infant born to an asymptomatic mother at a community hospital who required transfer to a local neonatal intensive care unit (NICU) immediately after birth for respiratory distress. The infant was tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at 24 hours of life by reverse transcription polymerase chain reaction (RT-PCR) testing due to the absence of prenatal maternal COVID-19 testing and was found to be positive for SARS-CoV-2 at that time. A second RT-PCR test was obtained on the infant on day of life (DOL) 4 and was also positive, confirming an accurate diagnosis of COVID-19 disease in the infant. Both the mother and father remained asymptomatic and concomitantly tested negative for SARS-CoV-2 on two separate occasions. The infant subsequently clinically improved and was discharged without any complications. This case raises the potential concern for two unreported newborn issues related to COVID-19. First, the potential unreliability of negative maternal COVID-19 testing surrounding the time of delivery as it relates to routine newborn testing and isolation needs, and second, if the negative material testing was accurate, this raises the concern for a potential case of nosocomial COVID-19 infection within the first 24 hours of life.


Sign in / Sign up

Export Citation Format

Share Document