COLLAPSE SEISMIC RISK ASSESSMENT FOR IRREGULAR MID-RISE BUILDINGS

Author(s):  
Lyan-Ywan Lu ◽  
Fu-Pei Hsiao ◽  
Yin-Nan Huang ◽  
Wei-Huan Hsieh

Mid-rise buildings, which may be used as office or apartment buildings, are very common structures in urban areas. Because these buildings are usually heavily populated, the casualty caused by the collapse of these structures in an earthquake could not be overestimated. Therefore, developing a suitable assessment method to identify these buildings with high collapse risk is an important issue. This paper presents a probabilistic assessment method, which involves nonlinear response-history analysis together with incremental dynamic analysis (IDA), to assess the collapse risk of a mid-rise building, so high-risk buildings and their damage patterns can be identified. This methodology is developed based on the procedure of collapse fragility analysis proposed by FEMA P-58, while the local and damage global criteria that define collapse failure are adopted from ASCE 41-13 and PEER-TBI, respectively. Finally, for demonstration, the proposed procedure is applied to assess the collapse risk of a mid-rise RC building that collapsed in a major earthquake occurred in Taiwan, 2016.

2021 ◽  
pp. 107754632110482
Author(s):  
Hamed Keikha ◽  
Gholamreza Ghodrati Amiri

Simplified analysis methods for seismically isolated structures proposed in recent structural codes and specifications are frequently used to reduce the computational effort and to simplify the design procedure, either directly for special cases or for checking the results of nonlinear response history analysis. Of the approximate methods, the equivalent lateral force procedure using the effective stiffness and effective damping is one of the best known. In this study, the simplified method is developed by combining the equivalent lateral force procedure with the capacity spectrum method and evaluated in terms of maximum isolator displacements and base shears for isolated structures with recently invented quintuple friction pendulum isolators , with different geometrical and frictional properties, under two different response spectra with corresponding two different sets of bidirectional near-field ground motions for stiff and soft soils site classes. In order to assess the accuracy of the simplified method, the delivered results of the ELF procedure are compared to those of nonlinear response history analysis, by modelling the quintuple friction pendulum isolator 3D element in OpenSees. Eventually, comments on the accuracy of the simplified method are given to make its applications more appropriate in practical design of base isolation systems.


2015 ◽  
Vol 31 (2) ◽  
pp. 1043-1067 ◽  
Author(s):  
F. Soner Alıcı ◽  
HalÛk Sucuoğlu

A practical implementation of generalized multimodal pushover analysis is presented in this study, where the number of pushovers is reduced significantly in view of the number of modes contributing to seismic response. It has been demonstrated in two case studies that the reduced procedure for generalized push-over analysis is equally successful in estimating the maximum member deformations and forces under a ground excitation with reference to nonlinear response history analysis. It is further shown that the results obtained by using the mean spectrum of a set of ground motions are almost identical to the mean of the results obtained from separate generalized pushover analyses. These results are also very close to the mean results of the nonlinear response history analyses, hence motivating the implementation of generalized pushover analysis with design spectrum.


Author(s):  
Gareth J. Morris ◽  
Andrew J. Thompson ◽  
James N. Dismuke ◽  
Brendon A. Bradley

Nonlinear response history analysis (NLRHA), or so-called “nonlinear time history analysis”, is adopted by practicing structural engineers who implement performance-based seismic design and/or assessment procedures. One important aspect in obtaining reliable output from the NLRHA procedure is the input ground motion records. The underlying intention of ground motion selection and amplitude-scaling procedures is to ensure the input for NLRHA is representative of the ground shaking hazard level, for a given site and structure. The purpose of this paper is to highlight the salient limitations of the ground motion selection and scaling requirements in Sections 5.5 and 6.4 of the New Zealand (NZ) loading standard NZS 1170.5 (2004). From a NZ regulatory perspective; there is no specific framework for seismic hazard analysis and ground motion selection (thus self-regulation is the current norm). In contrast, NZS 1170.5 contains many prescriptive requirements for scaling and applying records which are challenging to satisfy in practice. Also discussed within, there are implications for more modern guidance documents in NZ, such as the 2017 “Assessment Guidelines” for existing buildings, which cite NZS 1170.5, a standard which is at least 16 years old (draft issued in 2002). To emphasize the above issues with NZS 1170.5, this paper presents a summary of the more contemporary approaches in the US standards ASCE 7-16 (new buildings) and ASCE 41-17 (existing buildings), along with some examples of the more stringent US requirements for Tall Buildings.


Sign in / Sign up

Export Citation Format

Share Document