scholarly journals Experimental analysis and ANN prediction on performances of finned oval-tube heat exchanger under different air inlet angles with limited experimental data

Open Physics ◽  
2020 ◽  
Vol 18 (1) ◽  
pp. 968-980
Author(s):  
Xueping Du ◽  
Zhijie Chen ◽  
Qi Meng ◽  
Yang Song

Abstract A high accuracy of experimental correlations on the heat transfer and flow friction is always expected to calculate the unknown cases according to the limited experimental data from a heat exchanger experiment. However, certain errors will occur during the data processing by the traditional methods to obtain the experimental correlations for the heat transfer and friction. A dimensionless experimental correlation equation including angles is proposed to make the correlation have a wide range of applicability. Then, the artificial neural networks (ANNs) are used to predict the heat transfer and flow friction performances of a finned oval-tube heat exchanger under four different air inlet angles with limited experimental data. The comparison results of ANN prediction with experimental correlations show that the errors from the ANN prediction are smaller than those from the classical correlations. The data of the four air inlet angles fitted separately have higher precisions than those fitted together. It is demonstrated that the ANN approach is more useful than experimental correlations to predict the heat transfer and flow resistance characteristics for unknown cases of heat exchangers. The results can provide theoretical support for the application of the ANN used in the finned oval-tube heat exchanger performance prediction.

2014 ◽  
Vol 18 (3) ◽  
pp. 863-874 ◽  
Author(s):  
Xueping Du ◽  
Yantao Yin ◽  
Min Zeng ◽  
Pengqing Yu ◽  
Qiuwang Wang ◽  
...  

A tremendous quantity of water can be saved if the air cooling system is used, comparing with the ordinary water-cooling technology. In this study, two kinds of finned tube heat exchangers in an indirect air-cooling tower are experimentally studied, which are a plain finned oval-tube heat exchanger and a wavy-finned flat-tube heat exchanger in a cross flow of air. Four different air inlet angles (90?, 60 ?, 45?, and 30?) are tested separately to obtain the heat transfer and resistance performance. Then the air-side experimental correlations of the Nusselt number and friction factor are acquired. The comprehensive heat transfer performances for two finned tube heat exchangers under four air inlet angles are compared. For the plain finned oval-tube heat exchanger, the vertical angle (90?) has the worst performance while 45? and 30? has the best performance at small ReDc and at large ReDc, respectively. For the wavy-finned flat-tube heat exchanger, the worst performance occurred at 60?, while the best performance occurred at 45? and 90? at small ReDc and at large ReDc, respectively. From the comparative results, it can be found that the air inlet angle has completely different effects on the comprehensive heat transfer performance for the heat exchangers with different structures.


Author(s):  
K. Mohammadi ◽  
W. Heidemann ◽  
H. Mu¨ller-Steinhagen

A semi-analytical model is presented for the evaluation of the performance factor of the inlet zone of an E type shell and tube heat exchanger without leakage flows. The performance factor is defined as the ratio of dimensionless heat transfer coefficients and pressure drops of both vertical and horizontal baffle orientation and therefore facilitates the decision between horizontal and vertical baffle orientation of shell and tube heat exchangers. The model allows the calculation of the performance factor of the inlet zone as a function of the baffle cut, the shell-side Reynolds number at the inlet nozzle and the Prandtl number of the shell-side fluid. The application of the model requires the knowledge of the performance factor of water at baffle cut equal to 24% of the shell inside diameter. For the development of the model a numerical data basis is used due to the lack of experimental data for shell and tube heat exchangers with different baffle orientations. The numerical data are obtained from CFD calculations for steady state conditions within a segmentally baffled shell and tube heat exchanger following the TEMA standards. Air, water and engine oil with Prandtl numbers in the range of 0.7 to 206 are used as shell-side fluids. The semi-analytical model introduced for the performance factor predicts the CFD results with a relative absolute error less than 5%. The presented model has to be validated with further experimental data and/or numerical results which explain the effect of baffle orientation on the shell-side heat transfer coefficient and pressure drop in order to check the general applicability.


2013 ◽  
Vol 50 (1) ◽  
pp. 374-383 ◽  
Author(s):  
Xiang-hui Tan ◽  
Dong-sheng Zhu ◽  
Guo-yan Zhou ◽  
Li-ding Zeng

2021 ◽  
Vol 15 (2) ◽  
pp. 7936-7947
Author(s):  
Yamina Abdoune ◽  
Sahel Djamel ◽  
Benzeguir Redouane ◽  
Alem Karima

The forced convective heat transfer behavior of a turbulent air flow, steady and Newtonian over a fin and oval-tube heat exchanger has been examined numerically. Where, the effect of the tube tilt angle (α) on the heat transfer coefficient and the friction factor was tested. The inclination angle of the oval-tubes going from 0° (Baseline case) to 90° with a step of 10°. The fluid flows and heat transfer characteristics are presented for Reynolds numbers ranging from 3.000 to 12.000. All investigations are carried out with the help of the CFD ANSYS Fluent. Heat transfer coefficient results in the term of the Nusselt number are validated with the available experimental data and a maximum deviation of 9 % is observed. Reasonable agreement is found. The obtained results show that the tube's inclination angle of 20° is the best design which significantly removes the hot spots behind the tubes, thus giving an increase in the heat transfer coefficient of 13 % compared to the baseline case. In addition, useful correlations are developed to predict Nusselt number and friction factor in the fin and oval-tube heat exchanger.


Author(s):  
Hie Chan Kang ◽  
Hyun Soon Jang

An experimental study has been conducted on natural convection heat transfer for seventeen kinds of circular finned tube heat exchanger. The transient method was used to obtain the heat transfer coefficient. The experimental data were presented and their characteristics lengths were discussed. The experimental data were presented and correlated in the ranges of 27 < RaDh < 2300, 1.2 < Do/Di < 2.8, and 0.12 < Pf/Di < 0.26. The Nusselt number correlated with the quarter power of the Rayleigh number, based on the hydraulic diameter, for the small diameter fins, the same as laminar natural convection; however, the correlation was with the half power for the large fin diameters and small fin pitches.