scholarly journals A comparative evaluation of three dimensional accuracy of different types of interocclusal recording materials - an in vitro study

Author(s):  
Aparna Dwivedi ◽  
Kavita Maru ◽  
Aakash Sharma

Introduction. The interocclusal registration materials record the occlusal relationship between the natural and /or artificial teeth for planning an occlusal rehabilitation in removable and fixed partial dentures. Aim and objectives. The aim of this in vitro study was to evaluate and compare the accuracy and the three dimensional stability offered by three different types of interocclusal recording materials at storage time intervals of 1 hour and 24 hours. Methods. Three commercially available interocclusal recording materials were used - Group I - Polyether bite registration paste (Ramitec), Group II- Polyvinylsiloxane bite registration material (Imprint), Group III- Bite registration wax (Maarc).The test was carried out using an epoxy resin model. A total of 30 samples were made with each group consisting of ten samples. Three dimensional measurements were carried out by using 3D-Coordinate measuring machine (CMM) at time intervals of 0-1 hour and 0-24 hours in X, Y and Z- axis.   Results. Twelve readings were obtained for three axes (4 readings for each sample at 1 axis) and the averages of these four values were noted for a particular axis (X/Y/Z). Statistical analysis was performed using analysis of variance (ANOVA) for comparison among the groups and then Tukey’s honestly significant difference (HSD) tests was performed for comparison among groups at the 0.05 level of significance. Conclusion. Polyvinylsiloxane was dimensionally the most stable material followed by polyether and finally bite registration wax. Dimensional accuracy and stability is influenced by both “material” and “time” factors.

2018 ◽  
Vol 6 (02/03) ◽  
pp. 106-111
Author(s):  
Ramandeep Kaur ◽  
Manjit Kumar ◽  
Shailesh Jain ◽  
Neha Jindal

Abstract Statement of Problem The adhesion of impression material to impression tray is very important. Tray adhesive plays a major role in making accurate impression. Although manufactures recommend the use of particular tray adhesives, comparison of their affective adhesiveness has not been reported. The effect of use of tray adhesives on dimensional accuracy of dies has not been established. Purpose The aim of this study was to compare the dimensional accuracy of dies using different tray adhesives at different time intervals. Materials and Methods First part of study comprised 120 samples in six groups with 20 samples in each group. First group comprised samples with no tray adhesive, and in other five groups, different types of tray adhesives were applied. The dies obtained were evaluated for upper diameter, lower diameter, and occlusogingival height. In the second part, there were a total of 125 samples in five groups with 25 samples in each group. Five different types of tray adhesive were applied for five different time intervals 5, 10, 15, 20, and 25 minutes, respectively. The specimens were tested in tensile mode for its debonding force at a crosshead speed of 5 mm/min, until separation failure occurred. Results Significant difference was seen for upper and lower diameters when compared with the group without any tray adhesive. The maximum bond strength was found in the group in which tray adhesive was applied for 20 minutes.


2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Hussam Mutwalli ◽  
Michael Braian ◽  
Deyar Mahmood ◽  
Christel Larsson

Aim. To measure the trueness and precision under repeatable conditions for different intraoral scanners (IOSs) when scanning fully edentulous arch with multiple implants. Materials and Methods. Three IOSs and one industrial scanner were used to scan one edentulous master cast containing five implant scan bodies and three spheres. The cast was scanned thirty times with each scanner device. All scans were analyzed in the inspect software, and three-dimensional locations of the implants and the interarch distance between the spheres were measured. The values were compared to measurements made with one coordinate measuring machine (true value). One-way ANOVA was used to calculate the differences between IOSs and in comparison with the true value. Results. Significant differences were found between all IOSs. For the implant measurements, Trios 3 had the lowest trueness (≤114 μm), followed by Trios 3 mono (≤63 μm) and Itero element (≤−41 μm). Trios had the lowest precision (≤135 μm), followed by Itero element (≤101 μm) and Trios 3 mono (≤100 μm). With regard to the interarch distance measurements, Trios 3 had the lowest trueness (≤68 μm), followed by Trios 3 mono (≤45 μm) and Itero element (≤40 μm). Trios 3 had the lowest precision (≤206 μm), followed by Itero element (≤124 μm) and Trios 3 mono (≤111 μm). Conclusion. The results from this in vitro study suggest that precision is low for the tested IOS devices when scanning fully edentulous arches with multiple implants.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Sonam Gupta ◽  
Aparna Ichalangod Narayan ◽  
Dhanasekar Balakrishnan

Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique.Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n=5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA.Results. Statistically significant difference (p<0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p>0.05) was observed between varied stock and custom trays.Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.


2018 ◽  
Vol 1 (2) ◽  
pp. 67-74
Author(s):  
Anisha Pandey ◽  
S.R.B. Mathema ◽  
S.K. Maharjan

Introduction: Dimensional accuracy of cast obtained after making impressions is crucial factor for the quality of fixed prosthodontic treatment. The impression technique with different thickness of putty wash material is critical factor affecting this accuracy. There is much discussion in the dental literature concerning the effect of this impression technique on the accuracy of cast restorations. Materials and methods: This in-vitro study was carried out in 60 impression made from master model with Polyvinyl siloxane impressions material using single step putty- wash technique and two step putty-wash technique with varying spacer thickness (0.5mm, 1mm, 1.5 mm). It was further divided into four groups. Group I: Single step putty-wash impression technique, Group II: Two step putty-wash impression technique with 0.5mm spacer, Group III: Two step putty-wash impression technique with 1mm spacer, Group IV: Two step putty-wash impression technique with 1.5mm spacer. Each group consists of 15 impressions. Casts were poured using type IV dental stone after 1 hour. After 24 hour the die of each cast was scanned using CAD/CAM digital scanner and measured mesiodistally, facio-lingually, height (cervico-occlusally), interabutment or interdie distances. The data were recorded and statically analyzed. Results: The highest mean values of mesio-distal, bucco-lingual, cervico-occlusal distances were shown by Group I, whereas the inter-die distance showed equal mean value in Group I, II and III. With the increase in the spacer thickness, the mean value also increases in mesio-distal distance. The mean measurement of bucco-lingual dimension was highest when spacer thickness was 0.5mm and it declined with the increase in spacer thickness. The spacer thickness had no effect on cervico-occlusal and inter-die dimensions. Conclusions: Within the limitations of the study, accuracy of cast obtained from single step putty-wash technique was more accurate than two step putty-wash technique. In two step putty-wash technique, 1.5 mm thickness of spacer showed more accurate cast in comparison to 0.5mm and 1mm.


Author(s):  
Amit Baban Pokharkar ◽  
Umesh Gopal Palekar ◽  
Veena Saraf ◽  
Deepak Machindra Vikhe ◽  
Shefali Sevakram Bhiwapurkar ◽  
...  

Introduction: The conventional impression procedure plays a major role in prosthodontics inspite of advancement in intra- oral scanning devices and 3D imaging procedures. Dimensional accuracy and surface detail reproduction are important for recording an impression. Aim: The study evaluated and compared the dimensional accuracy and surface detail reproduction of Polyvinyl Siloxane (PVS) and vinyl siloxane ether impression materials when used under dry and moist conditions. Materials and Methods: An in-vitro study was conducted in the Department of Prosthodontics, Rural Dental College, Pravara Institute of Medical Sciences, Loni, Ahmednagar, Maharashtra, India, for a period of two years from October 2018 to September 2020. A total of 60 impressions were made with PVS (Group A) and vinyl siloxane ether (Group B) under dry (A1, B1) and moist (A2, B2) conditions of stainless steel dies which had lines engraved on superior surface of the die. Using a Harloc’s Tool maker’s microscope, dimensional accuracy was measured by comparing the width of line Y in each impression. Surface detail reproduction was evaluated by American Dental Association (ADA) specification no. 19 where it stated continuous replication of at least any two lines out of the three lines inscribed on the die. Data analysis processing was performed in the SYSTAT version 12 (made by Crane’s software, Bangalore). Student’s unpaired t-test and Chi-square test were performed to determine statistical difference between PVS and vinyl siloxane ether where the level of significance was set at 5% and 1%. Results: The mean dimensional change and SD values for PVS under dry condition ranged from 21.93±2.46 to 22.40±2.89 (in mm). The mean dimensional change and SD values for PVS under moist condition ranged from 22.87±3.20 to 23.33±3.42. The mean dimensional change and SD values for vinyl siloxane ether under dry condition ranged from 21.93±3.61 to 24.73±5.20. The mean dimensional change and SD values for vinyl siloxane ether under moist condition ranged from 21.93±4.48 to 22.87±4.15. No statistical difference was found under dry and moist conditions within 2 hours and after 24 hours for both the materials. Conclusion: The study revealed no significant difference between dimensional accuracy and surface detail reproduction for PVS and vinyl siloxane ether. Both the materials can reproduce the details under dry and moist conditions satisfactorily and remained dimensionally stable till 24 hours after impression making.


2019 ◽  
Vol 9 (19) ◽  
pp. 4197
Author(s):  
Shahabe Saquib ◽  
AlQarni Abdullah ◽  
Das Gotam ◽  
Naqash Talib ◽  
Sibghatullah Muhammad ◽  
...  

Splinting of the mobile teeth is a critical part of periodontal management to improve the prognosis and longevity of stable results of periodontally compromised teeth with increased mobility. Different types of splints are used in the dental field based on their mechanical and physical properties.The objective of the current in vitro study was to evaluate the flexure strength and flexural modulus of different types of splinting materials, such as: composite block, ligature wire, Ribbond®, InFibra®, and F-splint-Aid® bonded utilizing Flowable composites resin material. Seventy-five bar specimens were prepared with the dimensions of 25 × 4 × 2 mm, utilizing split metallic mold. Specimens were divided equally (n = 15) into five groups (one control group, four test groups). Different layers of splinting material were placed in between the layers of composite before curing. All the specimens were subjected to a three-point bending test by using a universal testing machine to calculate the flexural strength and flexural modulus. The entire data was subjected to statistical tests to evaluate the significance. Specimens from composite block groups showed the least mean value for flexural strength (89.15 ± 9.70 MPa) and flexural modulus (4.310 ± 0.912 GPa). Whereas, the highest mean value for flexural strength (168.04 ± 45.95 MPa) and flexural modulus (5.861 ± 0.501 GPa) were recorded by Ribbond® specimens. Inter group comparison of flexural strength showed statistically significant differences (P-value < 0.05), whereas comparison of flexural modulus showed non-significant difference among the groups (P-value > 0.05). Within the limitation of the present study, it was concluded that the Ribbond® exhibits maximum flexural strength and flexural modulus, whereas the composite blocks recorded the least values. Still, the decision making depends on the clinical scenario and the unique characteristic of each splint material.


Author(s):  
Kavneet Takhar ◽  
Neetu Jindal ◽  
Renu Agarwal ◽  
Megha Rani ◽  
Shallu Bansal

Abstract Aim and Objective The present in vitro study was done to comparatively evaluate the effect of different endodontic irrigation protocols on the microhardness at coronal, middle, and apical levels of root canal dentin. Method The total sample size for the study was 100. Each sample consisted of a longitudinally sectioned half of a root of a single-rooted tooth, which was then embedded in acrylic resin. The prepared samples were divided randomly into five groups of twenty samples each. Each group was treated with its respective irrigant to be tested. Group I was the control—the specimens were treated with distilled water. The specimens in group II were treated with sodium hypochlorite (NaOCl), followed by ethylenediamine tetra-acetic acid (EDTA). Specimens in group III were treated with NaOCl, followed by CHX. Specimens in group IV were treated with NaOCl, followed by hydroxyethylidene bisphosphonate (HEBP), and specimens in group V were treated with NaOCl, followed by propolis. Following this, all the samples were placed on the Vickers microhardness tester, and the results were tabulated and statistically analyzed to determine the irrigant solutions' effect on the microhardness of root dentin at coronal, middle, and apical third. Results Intergroup comparison of various irrigants showed that 18% HEBP showed the least reduction in the microhardness values of root canal dentin, and 17% EDTA caused the maximum decrease in microhardness values with a significant difference. When the baseline values were compared with the values after the use of experimental solutions in all the groups, it was observed that the microhardness gradually decreased from coronal to apical third of root dentin. Conclusion On the basis of the results obtained, it can be concluded that weak chelators such as 18% HEBP do not affect the microhardness considerably, and that they can be used in future in place of strong chelators, that is, EDTA, which make root dentin weak by more microhardness reduction.


Author(s):  
Sangeeta Kulkarni ◽  
Mohammed Mustafa ◽  
Kiran Ghatole ◽  
Ali Robaian AlQahtani ◽  
Faris Yahya I. Asiri ◽  
...  

Abstract Objectives The aim of this study was to evaluate the effects of 2% chlorhexidine gluconate (CHG) and 2% sodium fluoride (NaF) as endodontic irrigants on microhardness of root dentin. Materials and Methods In this in vitro study, access cavity and root canal preparations were done on 24 freshly extracted anterior teeth. After sectioning into 24 dentin discs using hard tissue microtome in 2 mm thickness, all samples were immersed in solutions of 17% ethylenediamine tetra-acetic acid (EDTA) (2 minutes) followed by 2.5% of sodium hypochlorite (NaOCl) (10 minutes). Then samples were randomly divided into three groups based on the irrigant used: Group I: saline (control group); Group II: 2% NaF; Group III: 2% CHG for two minutes each. Dentin microhardness was measured before (pretreatment), during (after treatment with 17% EDTA and 2.5% NaOCl), and after the experimental period (after treatment with saline, 2% NaF, and 2% CHG) using a Vickers indenter. Statistical evaluation of the data was done using one-way analysis of variance (ANOVA) and the Student’s t-test, and the values are tabulated. Results Specimens rinsed in 2% CHG showed a significant increase in Vickers hardness number (VHN) values (p < 0.05), as compared with EDTA and NaOCl groups, whereas saline and 2% NaF groups showed no significant difference. Conclusions NaF did not show any significant effect on microhardness of the root dentin. CHG as an irrigant was seen to have a strengthening effect on dentin microhardness in comparison to NaOCl and EDTA, which has decreased the strength of root dentin.


Sign in / Sign up

Export Citation Format

Share Document