scholarly journals High Frequency Pure Tone Audiometry and High Frequency Distortion Product Otoacoustic Emissions: A Correlational Analysis

2000 ◽  
Author(s):  
Kimberly Lavoie
2015 ◽  
Vol 129 (12) ◽  
pp. 1174-1181 ◽  
Author(s):  
N Wooles ◽  
M Mulheran ◽  
P Bray ◽  
M Brewster ◽  
A R Banerjee

AbstractObjective:To examine whether distortion product otoacoustic emissions can serve as a replacement for pure tone audiometry in longitudinal screening for occupational noise exposure related auditory deficit.Methods:A retrospective review was conducted of pure tone audiometry and distortion product otoacoustic emission data obtained sequentially during mandatory screening of brickyard workers (n = 16). Individual pure tone audiometry thresholds were compared with distortion product otoacoustic emission amplitudes, and a correlation of these measurements was conducted.Results:Pure tone audiometry threshold elevation was identified in 13 out of 16 workers. When distortion product otoacoustic emission amplitudes were compared with pure tone audiometry thresholds at matched frequencies, no evidence of a robust relationship was apparent. Seven out of 16 workers had substantial distortion product otoacoustic emissions with elevated pure tone audiometry thresholds.Conclusion:No clinically relevant predictive relationship between distortion product otoacoustic emission amplitude and pure tone audiometry threshold was apparent. These results do not support the replacement of pure tone audiometry with distortion product otoacoustic emissions in screening. Distortion product otoacoustic emissions at frequencies associated with elevated pure tone audiometry thresholds are evidence of intact outer hair cell function, suggesting that sites distinct from these contribute to auditory deficit following ototrauma.


Author(s):  
Ö Gedik ◽  
H Hüsam ◽  
M Başöz ◽  
N Tas ◽  
F Aksoy

Abstract Objective This study aimed to evaluate different auditory regions with audiological tests, based on the presumption that there may be damage to the structures in the hearing system after coronavirus disease 2019. Methods Twenty individuals with no history of coronavirus disease 2019 and 27 individuals diagnosed with coronavirus disease 2019 were compared. Pure tone, speech and extended high-frequency audiometry, acoustic immitansmetry, transient evoked and distortion product otoacoustic emissions testing, and auditory brainstem response testing were conducted. Results The pure tone audiometry and extended high-frequency mean threshold values were higher in the coronavirus disease 2019 group. The transient evoked otoacoustic emissions signal-to-noise ratios were bilaterally lower at 4 kHz in individuals with a coronavirus disease 2019 history. In the auditory brainstem response test, only the interpeak latencies of waves III–V were significantly different between groups. Conclusion Coronavirus disease 2019 may cause damage to the hearing system. Patients should be followed up in the long term with advanced audiological evaluation methods in order to determine the extent and level of damage.


2016 ◽  
Vol 1 (1) ◽  
Author(s):  
Anisha Kocchar ◽  
Rohit Sharma ◽  
Piyush Kumar ◽  
Vineet Sharma ◽  
Kumar Shubhanshu

<bold>Introduction:</bold> Chemoradiation is an important component in the management of Head and Neck Cancers, which has hearing loss as a major adverse effect. This is due to the inclusion of ear structures in the radiation field and Cisplatin, an anti-neoplastic drug which can cause ototoxicity. The role of audiological screening in the form of Pure Tone Audiometry & Distortion Product Otoacoustic Emissions is hereby studied in these patients. <bold>Material and Methods:</bold> The present study was undertaken to highlight the effects of concurrent chemoradiation on the audiological profile of Head and Neck Cancer patients. The patients underwent pre-treatment and post treatment Pure Tone Audiometry and Distortion Product Otoacoustic Emission. The results were statistically analysed. <bold>Results:</bold> 36 patients who underwent concurrent chemoradiation for Head and Neck Cancers were enrolled. Post treatment PTA values were significantly different from Pre-treatment values especially at 500Hz. DPOAEs also indicated significant changes in cochleotoxicity grading after concurrent chemoradiation. <bold>Conclusion:</bold> Concurrent Chemoradiation exerts a significant effect on hearing status of the patients. Simple screening tests like DPOAE can detect cochlear damage prior to detection with Pure Tone Audiometry. Addition of these tests is recommended as routine screening during Concurrent Chemoradiation.


Author(s):  
Nuriye Yıldırım Gökay ◽  
Bülent Gündüz ◽  
Fatih Söke ◽  
Recep Karamert

Purpose The effects of neurological diseases on the auditory system have been a notable issue for investigators because the auditory pathway is closely associated with neural systems. The purposes of this study are to evaluate the efferent auditory system function and hearing quality in Parkinson's disease (PD) and to compare the findings with age-matched individuals without PD to present a perspective on aging. Method The study included 35 individuals with PD (mean age of 48.50 ± 8.00 years) and 35 normal-hearing peers (mean age of 49 ± 10 years). The following tests were administered for all participants: the first section of the Speech, Spatial and Qualities of Hearing Scale; pure-tone audiometry, speech audiometry, tympanometry, and acoustic reflexes; and distortion product otoacoustic emissions (DPOAEs) and contralateral suppression of DPOAEs. SPSS Version 25 was used for statistical analyses, and values of p < .05 were considered statistically significant. Results There were no statistically significant differences in the pure-tone audiometry thresholds and DPOAE responses between the individuals with PD and their normal-hearing peers ( p = .732). However, statistically significant differences were found between the groups in suppression levels of DPOAEs and hearing quality ( p < .05). In addition, a statistically significant and positive correlation was found between the amount of suppression at some frequencies and the Speech, Spatial and Qualities of Hearing Scale scores. Conclusions This study indicates that medial olivocochlear efferent system function and the hearing quality of individuals with PD were affected adversely due to the results of PD pathophysiology on the hearing system. For optimal intervention and follow-up, tasks related to hearing quality in daily life can also be added to therapies for PD.


2013 ◽  
Vol 127 (10) ◽  
pp. 952-956 ◽  
Author(s):  
A Goyal ◽  
P P Singh ◽  
A Vashishth

AbstractObjectives:This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters.Methods:A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing.Results:The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs.Conclusion:Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.


2007 ◽  
Vol 25 (10) ◽  
pp. 1190-1195 ◽  
Author(s):  
Kristin R. Knight ◽  
Dale F. Kraemer ◽  
Christiane Winter ◽  
Edward A. Neuwelt

Purpose The objective is to describe progressive changes in hearing and cochlear function in children and adolescents treated with platinum-based chemotherapy and to begin preliminary evaluation of the feasibility of extended high-frequency audiometry and distortion product otoacoustic emissions for ototoxicity monitoring in children. Patients and Methods Baseline and serial measurement of conventional pure-tone audiometry (0.5 to 8 kHz) and evoked distortion product otoacoustic emissions (DPOAEs) were conducted for 32 patients age 8 months to 20 years who were treated with cisplatin and/or carboplatin chemotherapy. Seventeen children also had baseline and serial measurement of extended high-frequency (EHF) audiometry (9 to 16 kHz). Audiologic data were analyzed to determine the incidence of ototoxicity using the American Speech-Language-Hearing Association criteria, and the relationships between the different measures of ototoxicity. Results Of the 32 children, 20 (62.5%) acquired bilateral ototoxicity in the conventional frequency range during chemotherapy treatment, and 26 (81.3%) had bilateral decreases in DPOAE amplitudes and dynamic range. Of the 17 children with EHF audiometry results, 16 (94.1%) had bilateral ototoxicity in the EHF range. Pilot data suggest that EHF thresholds and DPOAEs show ototoxic changes before hearing loss is detected by conventional audiometry. Conclusion EHF audiometry and DPOAEs have the potential to reveal earlier changes in auditory function than conventional frequency audiometry during platinum chemotherapy in children.


2016 ◽  
Vol 22 ◽  
pp. 2028-2034 ◽  
Author(s):  
Ualace De Paula Campos ◽  
Stavros Hatzopoulos ◽  
Lech K. Śliwa ◽  
Piotr H. Skarżyński ◽  
Wiesław W. Jędrzejczak ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document