scholarly journals Seismic Performance of a Hybrid Coupled Wall System Using different Coupling Beam Arrangements

Teknik Dergi ◽  
2022 ◽  
Author(s):  
Molham SALAMEH ◽  
Mohsenali SHAYANFAR ◽  
Mohammad BARKHORDARİ
2012 ◽  
Vol 256-259 ◽  
pp. 737-741
Author(s):  
An Liang Song ◽  
Ming Zhou Su ◽  
Xu Dong Li ◽  
Yun Shi ◽  
Zhen Shan Wang

Based on the state-of-the-art of the research on connection of steel coupling beam to shear wall, The steel coupling beam has satisfactory seismic performance which is better than reinforced concrete coupling beams and composite coupling beams. In this paper, the existing research results were summarized and some views were put forward. It was useful to develop a seismic design method for hybrid coupled walls in China.


2018 ◽  
Vol 22 (6) ◽  
pp. 1284-1296 ◽  
Author(s):  
Yong Li ◽  
Ye Liu ◽  
Shaoping Meng

Coupled wall systems are often used in high-rise buildings in zone of high seismic risk to provide lateral resistance to earthquake loading. Once damaged, reinforced concrete coupling beams are costly and time-consuming to repair post-earthquake. To enhance the seismic resilience for coupled wall structures, a novel replaceable steel truss coupling beam is first introduced. The proposed replaceable steel truss coupling beam consists of chord members at the top and bottom, respectively, and two buckling-restrained energy dissipaters are employed in the diagonal direction. The energy dissipaters can yield first before the wall piers and dissipate large amounts of energy to protect the main structure under seismic loadings. In addition, the energy dissipaters can be easily installed and post-earthquake repaired through pin connection with the chord members. This article mainly focused on the numerical and theoretical analyses of the proposed replaceable steel truss coupling beam, and nonlinear analytical models were developed in PERFORM-3D. An 11-story prototype structure was designed per Chinese code. The seismic response of hybrid coupled wall system with replaceable steel truss coupling beams was evaluated using nonlinear time history analysis and compared with the response of reinforced concrete coupled wall system with reinforced concrete coupling beams under seismic loadings. Results show that the proposed replaceable steel truss coupling beam leads to a good seismic response with reduced interstory drifts of the systems and rotational demand in the beams and wall piers due to a large energy dissipation capacity and overstrength.


2021 ◽  
Vol 240 ◽  
pp. 112307
Author(s):  
Xiaodong Ji ◽  
Junshan Zhang ◽  
Kohju Ikago ◽  
Sanjukta Chakraborty ◽  
Hideto Kanno

2014 ◽  
Vol 610 ◽  
pp. 78-83
Author(s):  
Ji Gang Zhang ◽  
Zhi Wei Jiang

Offshore platform rocking wall system and tuned mass damper are briefly introduced, and the paper integrates the advantages of these two kinds of seismic method, and the TMD is attached to the jacket offshore platform - rocking wall system, using the ANSYS for finite element analysis, and the analysis results are optimized. The results show that compared with the offshore platform - rocking wall system, additional TMD can give full play to the performances of the two kinds of seismic methods, which is remarkable.


2005 ◽  
Vol 61 (7) ◽  
pp. 912-941 ◽  
Author(s):  
Wan-Shin Park ◽  
Hyun-Do Yun ◽  
Sun-Kyoung Hwang ◽  
Byung-Chan Han ◽  
Il Seung Yang

2009 ◽  
Vol 18 (7) ◽  
pp. 807-822 ◽  
Author(s):  
Hee-San Chung ◽  
Byoung-Wook Moon ◽  
Sung-Kyung Lee ◽  
Ji-Hun Park ◽  
Kyung-Won Min

Sign in / Sign up

Export Citation Format

Share Document