scholarly journals Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market

2018 ◽  
Vol 17 ◽  
pp. 1-9
Author(s):  
Luiz Carlos do Carmo Filho ◽  
Ana Paula Pinto Martins ◽  
Amália Machado Bielemann ◽  
Anna Paula da Rosa Possebon ◽  
Fernanda Faot

Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5–1.0 μm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 μm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques.

Author(s):  
T. R. Davydova ◽  
А. I. Shaikhaliev ◽  
D. A. Usatov ◽  
G. A. Gasanov ◽  
R. S. Korgoloev

The aim of this study was to study the effect of surface branching of titanium endoprostheses on the efficiency of fibrointegration. The object of the study was samples of titanium alloy Ti6Al4V in the form of disks with a diameter of 5 mm and a thickness of 1 mm with various surface treatments: 1) samples with a rough surface after sandblasting; 2) samples with a rough surface after sandblasting with a bioactive coating of titanium dioxide TiO2 with anatase structure. The study of surface roughness was carried out by profilometry. Evaluation of the spreading and proliferation of cells on the surface of test samples, as well as evaluation of the effectiveness of fibrointegration was carried out according to standard methods using scanning electron microscopy. During the experiments, mesinchymal stem cells were sown on test samples and the test samples were introduced into the soft tissues of experimental animals. Based on the results obtained, it was concluded that the technology of forming rough surfaces by sandblasting does not provide high uniformity and reproducibility in the nanometer range and, apparently, another method for obtaining a rough surface should be chosen. The application of a bioactive coating of titanium dioxide TiO2 with the anatase structure to the surface of titanium endoprostheses increases the efficiency of fibrointegration, however, primarily the fibrointegration of titanium endoprostheses depends on their surface roughness, which determines the concentration of cell structures, the intensity of their adhesion and the ability to fibrointegrative process.


2021 ◽  
Vol 212 ◽  
pp. 106222
Author(s):  
Balázs Zsirka ◽  
Veronika Vágvölgyi ◽  
Katalin Győrfi ◽  
Erzsébet Horváth ◽  
Róbert K. Szilágyi ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1376
Author(s):  
Alex Quok An Teo ◽  
Lina Yan ◽  
Akshay Chaudhari ◽  
Gavin Kane O’Neill

Additive manufacturing of stainless steel is becoming increasingly accessible, allowing for the customisation of structure and surface characteristics; there is little guidance for the post-processing of these metals. We carried out this study to ascertain the effects of various combinations of post-processing methods on the surface of an additively manufactured stainless steel 316L lattice. We also characterized the nature of residual surface particles found after these processes via energy-dispersive X-ray spectroscopy. Finally, we measured the surface roughness of the post-processing lattices via digital microscopy. The native lattices had a predictably high surface roughness from partially molten particles. Sandblasting effectively removed this but damaged the surface, introducing a peel-off layer, as well as leaving surface residue from the glass beads used. The addition of either abrasive polishing or electropolishing removed the peel-off layer but introduced other surface deficiencies making it more susceptible to corrosion. Finally, when electropolishing was performed after the above processes, there was a significant reduction in residual surface particles. The constitution of the particulate debris as well as the lattice surface roughness following each post-processing method varied, with potential implications for clinical use. The work provides a good base for future development of post-processing methods for additively manufactured stainless steel.


2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Karl Niklas Hansson ◽  
Stig Hansson

The surface roughness affects the bone response to dental implants. A primary aim of the roughness is to increase the bone-implant interface shear strength. Surface roughness is generally characterized by means of surface roughness parameters. It was demonstrated that the normally used parameters cannot discriminate between surfaces expected to give a high interface shear strength from surfaces expected to give a low interface shear strength. It was further demonstrated that the skewness parameter can do this discrimination. A problem with this parameter is that it is sensitive to isolated peaks and valleys. Another roughness parameter which on theoretical grounds can be supposed to give valuable information on the quality of a rough surface is kurtosis. This parameter is also sensitive to isolated peaks and valleys. An implant surface was assumed to have a fairly well-defined and homogenous “semiperiodic” surface roughness upon which isolated peaks were superimposed. In a computerized simulation, it was demonstrated that by using small sampling lengths during measurement, it should be possible to get accurate values of the skewness and kurtosis parameters.


2012 ◽  
Vol 730-732 ◽  
pp. 9-14 ◽  
Author(s):  
Bruno Henriques ◽  
Filipe Silva ◽  
Delfim Soares

The purpose of this work was to perform a chemical and mechanical characterization of a preoxidized CoCrMo alumina blasted surface. This is a commonly performed surface treatment used in metal-porcelain systems for dental restorations to remove oxides formed during preoxidation heat treatment from the metal’s surface. CoCrMo dental alloy’s specimens produced by lost wax process were examined in terms of chemical composition using X-Ray fluorescence spectroscopy (XRF), Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray Spectroscopy (EDS); in terms of mechanical characteristics through the means of a microhardness test and in terms of surface roughness using a profilometer. It was investigated the chemical composition of various surface conditions: non-preoxidized, preoxidized, ground oxidized surface and sandblasted oxidized surface. After alumina blasting, the oxides level on metal’s surface remained high. Alumina blasting treatment (Ø110 µm) produced an 84% increase of CoCrMo surface hardening and an increase in surface roughness (Ra=0.58 µm). It was found alumina contaminants on the metal’s surface. Therefore, it was concluded that alumina blasting do not entirely removes the oxide layer formed during preoxidation heat treatment. It produced a chemical and mechanical surface modification that can influence the metal-ceramic bond strength.


2019 ◽  
Vol 944 ◽  
pp. 828-834 ◽  
Author(s):  
Jian Jun Wang ◽  
Jian Hua Sun ◽  
Shang Yu Yang ◽  
Yao Rong Feng ◽  
Kai Lin

During the processing of tubing premium threaded made up, the degree of the thread sealing surface intactness will directly affect the sealing performance of the string. Nevertheless, there are some difficulties to detect the damage of the engaged sealing surface effectively. In the present study the sealing surface damage was judged by the sealing surface contact stress’s relative changes according to the acoustic elasticity theory,. At the same time, the wear defects generated at the tubing sealing surface, during the tubing made up, contrasted with the wear and unworn surface roughness of coupling ultrasonic detected about the sealing surface. The results showed that with the acoustic amplitude evaluated the sealing contact stress was susceptible to the influence of surface roughness of coupling. But the reflection wave with the center frequency on the sealing surface characterization of the contact stress could avoid this problem effectively.


Materials ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 314 ◽  
Author(s):  
Ana Isabel Nicolas-Silvente ◽  
Eugenio Velasco-Ortega ◽  
Ivan Ortiz-Garcia ◽  
Loreto Monsalve-Guil ◽  
Javier Gil ◽  
...  

The implant surface features affect the osseointegration process. Different surface treatment methods have been applied to improve the surface topography and properties. Trace of different elements may appear on the implant surface, which can modify surface properties and may affect the body’s response. The aim was to evaluate the roughness based on the surface treatment received and the amount and type of trace elements found. Ninety implants (nine different surface treatment) were evaluated. Roughness parameters were measured using white-light-interferometry (WLI). The arithmetical mean for Ra, Rq, Rt, and Rz of each implant system was calculated, and Fisher’s exact test was applied, obtaining Ra values between 0.79 and 2.89 µm. Surface chemical composition was evaluated using X-ray photoelectron spectroscopy (XPS) at two times: as received by the manufacturer (AR) and after sputter-cleaning (SC). Traces of several elements were found in all groups, decreasing in favor of the Ti concentration after the sputter-cleaning. Within the limitations of this study, we can conclude that the surface treatment influences the roughness and the average percentage of the trace elements on the implant surface. The cleaning process at the implant surface should be improved by the manufacturer before assembling the implant.


1997 ◽  
Vol 51 (10) ◽  
pp. 1460-1463 ◽  
Author(s):  
Nobuaki Marino ◽  
Kiichirou Murai ◽  
Yoshinori Kataora

Characterization of nanometer-order organic contaminants on polymer film and silicon wafer surface has been investigated by a modified IR–Johnson method. We have proposed a silver film-enhanced IR–Johnson method that is useful for surface contaminant analysis. In the present method, organic traces are transferred from the surface of a polymer film or silicon wafer onto the KBr particles deposited with silver film, and then the KBr particles are analyzed directly by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). Infrared absorption of organic traces was enhanced by the presence of silver island film. With this method, a spectrum of nanometer-order organic traces can be obtained without any interference from the polymer film substrate. The present method is as surface-sensitive as X-ray photoelectron spectroscopy (XPS) and provides a large amount of information on the chemical structure of surface contaminants. This is a promising method for the surface characterization of polymer films and silicon wafer. Index Headings: Infrared; Diffuse reflectance; Surface enhancement.


2018 ◽  
Vol 22 (2) ◽  
Author(s):  
Nanang Qosim ◽  
Sugeng Supriadi ◽  
Agung Shamsuddin Saragih ◽  
Yudan Whulanza

Objective: This research aims to observe the extent to which several surface treatment techniques increase the surface roughness of titanium alloy implants which was manufactured via electrical discharge machining (EDM). The effects of these techniques were also observed to decrease the Cu content on the implant surface. Materials and Methods: In this research, ultrasonic cleaning, rotary tumbler polishing, and brushing were employed as techniques to increase the roughness of a titanium implant which was manufactured via EDM, to the moderately rough category, and to reduce the contaminant element deposited on its surface. An MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay test was also used to observe the effect of these engineered specimens with respect to mesenchymal stem cells’ proliferation. Results and Discussion: The results show that ultrasonic cleaning and rotary tumbler polishing created a significant increase (90% and 67%, respectively) in the surface roughness. On the other hand, brushing was shown to be the best benchmark for reducing the contamination of Copper (Cu). Furthermore, rotary tumbler polishing and brushing can increase the percentage of living cells compared to the original surface EDM specimens. Conclusion: All micro-finishing methods that were employed are able to increase the surface roughness of Ti alloy based-implant to moderately rough category.


Sign in / Sign up

Export Citation Format

Share Document