scholarly journals Inquisition of Electro-Magnetic Riga Plate for Laminar Flow

Author(s):  
Azad Hussain ◽  
Sobia Akbar ◽  
Muhammad Arshad ◽  
Sohail Nadeem

Abstract The probation is made to study the stagnation point flow of non-Newtonian fluid for Riga plate. Electric potential and magnetic flux density with time dependent flow is examined. Mesh for electric potential, magnetic flux, laminar flow with physics controlled fine, finer and extra finer option is also represented in details. Inquisition is solved in COMSOL Multi-physics 5.4 to obtain the results of surface magnitude, counter, table surface, magnetic flux, electric potential and coarse mesh for velocity, pressure, magnetic and electric fields. Coarse mesh of electric insulation and magnetic flux of the geometry is created with 6067, 18688 domain elements and 901, 1448 boundary elements. Tables for velocity surface, mesh domain, quadrilateral and triangular elements are also presented. Obtained results are discussed with graphs and tables in details.

Author(s):  
R. D. Rockwell ◽  
P. E. Allaire ◽  
M. E. F. Kasarda

No literature is currently available which has evaluated finite element power loss models for magnetic bearings and compared the results to experimental results. In this paper a finite element model of the magnetic and electric fields in magnetic bearings, including the motion of the magnetic material in the rotor, is developed. It evaluates the two dimensional magnetic vector potential, magnetic flux density, electric field, eddy current, and power losses in an example magnetic bearing configuration. Results were obtained for both a solid rotor and a laminated rotor. For a solid rotor, both the magnetic flux density and eddy current plots at high rotational speeds are concentrated at the outer edge of the rotor. The ratio of calculated solid to laminated losses is found to be in the range of measured results by other authors. An effective axial conductivity was employed to model a laminated rotor and compared to experimental loss measurements. The correlation between measured and calculated results is quite good for a range of rotor speeds, magnetic flux density, and air gap thickness.


Author(s):  
Ahmed El-Shahat ◽  
Ashraf. M ◽  
Waleed. A ◽  
K. Sayed

Introduction: Early recognition of stroke with its two types Ischemic and Hemorrhagic, is one of the most crucial research points, commonly used methods are CT- (computerized tomography), and MRI- (Magnetic resonance imaging). These techniques cause a delay in the detection of the condition, which causes permanent disability. The main reason behind the fatal consequences of stroke is the delay of detection. Therefore, this research paper aims to early detection of the type of stroke without delay until the appropriate diagnosis of each type is made, and then the appropriate treatment without delay. Method: Using a non-invasive and fast technique to determine the stroke type by wave, we simulate and design a vessel containing a liquid as a laminar flow with the same density and velocity of blood, and it was surrounded by a Homogenized multi-turn coil consisting of (n) turns to represent the magnetic field, using specific frequency (HZ) with Electrical field in coil current (A) to see the changing in magnetic flux density (MFD), Depending on the changes in MFD, the flow of blood in laminar flow can be affected by clotting (Ischemic) or Hemorrhagic (cutting) in our vessel designed. We have built three different scenarios to apply the technique which are: First: Normal Scenario (where the blood in vessel has no problem), second: clotting (ischemic, where the vessel blocked in specific three position) and Third: Cutting (Hemorrhagic, where the vessel cut in certain nine positions). Results: This paper presents-through our own design-the studying of applying the electromagnetic waves on blood inside the vessel to detect the stroke type in our three scenarios (normal, ischemic three positions or hemorrhagic nine positions), Studying the magnetic field and laminar flow. This study covered in three areas. First: coil geometry analysis, Second: stationary, and Third: frequency domain. through the changes in Magnetic Flux Density -MFD- waves. The results were promising and distinct for distinguishing between the three scenarios which are normal, ischemic (3 positions) and hemorrhagic (9 positions) the results of MFD are: 0.09 to 3.3*10^-3, 0.08 to 3.15*10^-4, 0.15 to 6.2*10^-3 respectively.


2021 ◽  
Vol 2090 (1) ◽  
pp. 012146
Author(s):  
M Nemaire ◽  
P Asensio ◽  
J-M Badier ◽  
J Leblond ◽  
J-P Marmorat

Abstract In this work, we consider the inverse source recovery problem from sEEG, EEG and MEG point-wise data. We regard this as an inverse source recovery problem for L2 vector-fields normally oriented and supported on the grey/white matter interface, which together with the brain, skull and scalp form a non-homogeneous layered conductor. We assume that the quasistatic approximation of Maxwell’s equation holds for the electro-magnetic fields considered. The electric data is measured point-wise inside and outside the conductor while the magnetic data is measured only point-wise outside the conductor. These ill-posed problems are solved via Tikhonov regularization on triangulations of the interfaces and a piecewise linear model for the current on the triangles. Both in the continuous and discrete formulation the electric potential is expressed as a linear combination of double layer potentials while the magnetic flux density in the continuous case is a vector-surface integral whose discrete formulation features single layer potentials. A main feature of our approach is that these contributions can be computed exactly. Due to the consideration of the regularity conditions of the electric potential in the inverse source recovery problem, the Cauchy transmission problem for the electric potential is inadvertently solved as well. In the problem, we propagate only the electric potential while the normal derivatives at the interfaces of discontinuity of the electric conductivities are computed directly from the resulting solution. This reduces the computational complexity of the problem. There is a direct connection between the magnetic flux density and the electrical potential in conductors such as the one we explore, hence a coupling of the sEEG, EEG and MEG data for solving the respective inverse source recovery problems simultaneously is direct. We treat these problems in a unified approach that uses only single and/or double layer potentials. We provide numerical examples using realistic meshes of the head with synthetic data.


2020 ◽  
pp. 3-7
Author(s):  
Vladlen Ya. Shifrin ◽  
Denis I. Belyakov ◽  
Alexander E. Shilov ◽  
Denis D. Kosenko

The results of works aimed at increasing the level of uniformity of measurements of the magnetic induction of a constant field – the basic value in the field of magnetic measurements. A set of equipment for reproducing a unit of magnetic induction of a constant field in the range of 1–25 mT was created and described. The inclusion of this complex in the State primary standard of units of magnetic induction, magnetic flux, magnetic moment and magnetic induction gradient GET 12-2011 will ensure the reproduction and direct transmission of the unit of permanent magnetic induction in the ranges of not only weak (10–3–1 mT), but medium (1–25 mT) and strong (0.025–1 T) magnetic fields. A quantum cesium magnetometer based on the resolved structure of cesium atoms was created to transmit the unit of magnetic induction to the region of medium fields. The procedure for calculating the frequency conversion coefficients to magnetic induction of the created quantum cesium magnetometer is described. The uncertainty budget for reproducing a unit of magnetic induction of a constant field using the created complex is estimated.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2522
Author(s):  
Guangdou Liu ◽  
Shiqin Hou ◽  
Xingping Xu ◽  
Wensheng Xiao

In the linear and planar motors, the 1D Halbach magnet array is extensively used. The sinusoidal property of the magnetic field deteriorates by analyzing the magnetic field at a small air gap. Therefore, a new 1D Halbach magnet array is proposed, in which the permanent magnet with a curved surface is applied. Based on the superposition of principle and Fourier series, the magnetic flux density distribution is derived. The optimized curved surface is obtained and fitted by a polynomial. The sinusoidal magnetic field is verified by comparing it with the magnetic flux density of the finite element model. Through the analysis of different dimensions of the permanent magnet array, the optimization result has good applicability. The force ripple can be significantly reduced by the new magnet array. The effect on the mass and air gap is investigated compared with a conventional magnet array with rectangular permanent magnets. In conclusion, the new magnet array design has the scalability to be extended to various sizes of motor and is especially suitable for small air gap applications.


Sign in / Sign up

Export Citation Format

Share Document