scholarly journals Application of a bone conserving revision stem for unstable intertrochanteric fractures in senile osteoporotic population

Author(s):  
MENGCUN CHEN ◽  
Jinlong Wang ◽  
Shuhua Yang ◽  
Xianzhe Liu

Abstract Purpose Primary hemi-arthroplasty is gaining rising attention to treat unstable intertrochanteric fractures in senile patients with severe osteoporosis. The objective of this study is to evaluate the early clinical and radiographic outcomes using bone conserving revision stem for unstable intertrochanteric fractures in senile osteoporotic population. Methods A retrospective observation of a series of 31 patients with unstable intertrochanteric fractures were conducted. The average age of the patients enrolled was 82.1 years and all patients underwent primary hemi-arthroplasty with the application of bone conserving and fully porous-coated revision stem. Clinical and radiographic evaluations during both the hospital-stay and follow-up were performed. Results The 31 patients were followed up for an average of 23 months postoperatively. The average operation time was 74.2 min while the mean intraoperative blood loss was 200.1 ml, with an average 11.1 g/L decrease of hemoglobulin after the procedure. The mean Harris hip score was 82.1 and visual analog scale was 1.7 at the latest follow-up. No intra-operative or postoperative peri-prosthetic fracture was noted. Postoperative complications included one thrombosis formation in posterior tibial vein and one congestive heart failure, both patients were discharged uneventfully after treatment. Twenty-one (21/31, 67.7%) patients regained their pre-injury walking activities. Radiographically, none of these hips had evident loosening of the stem or osteolysis. With follow-up period of 23 months, the mortality rate was 3.2% (1/31) with no revision required. Conclusion Primary hemi-arthroplasty with application of the bone conserving, cementless revision stem could serve as a reliable alternation in treatment of unstable intertrochanteric fractures in senile population with osteoporosis.

2021 ◽  
pp. 55-56
Author(s):  
Anshul Khare ◽  
Shailandra Pandey ◽  
Aman Agrahari ◽  
Abhishek Pathak ◽  
Sanjiv Gaur

There is no perfect implant for intertrochanteric fractures. Nowadays Proximal Femoral Nail (PFN) is getting popular in these fractures. In this study we tried to nd and analyse the outcome of using PFN in 20 cases of unstable intertrochanteric fractures which were operated at our centre and completed the follow up till 6 months. These patients were analysed on various intra-operative and post-operative parameters. Functional assessment was done using Harris Hip Score. The mean age of patients in our study was 64 years. Average incision length was around 6.5cm and mean blood loss was 97ml. Average surgery duration was 71 minutes while average hospital stay was 18.1 days. Mean time to union was 14.9 weeks. All cases have achieved union. Varus malalignment was observed in one case. Harris Hip Score showed excellent results in 60% cases and good results in 30% cases. Our study indicates that PFN is a good implant for xation of unstable intertrochanteric fractures. However it superiority over other implants can only be conrmed with larger comparative studies.


2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background: Dorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.Methods: A total of 42 hip arthroplasties were performed in 35 young patients (range, 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 ± 3.7 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3). Results: The mean follow-up period was 5.5 ± 1.1 years (range, 3.0–8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0±0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5±0.7 points (range, 6.0–8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutral to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.Conclusions: Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract Background Dorr type C femoral bone exhibits a wide, stovepipe-shaped femoral canal, and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation. Methods A total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index ≤ 3). Results The mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up. Conclusions Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


2015 ◽  
Vol 9 (1) ◽  
pp. 456-459 ◽  
Author(s):  
G.N. Kiran Kumar ◽  
Gaurav Sharma ◽  
Kavin Khatri ◽  
Kamran Farooque ◽  
Devendra Lakhotia ◽  
...  

Introduction:Unstable intertrochanteric fractures are difficult to manage and the choice of implant is critical for fracture fixation. The purpose of this study was to evaluate the functional and radiological outcome of proximal femoral nail antirotationII (PFNA II) in the treatment of unstable intertrochanteric fractures.Materials and Methods:We reviewed 45 patients of unstable intertrochanteric fractures, who were treated with the PFNA II between 2011 and 2013. Of which, 3 patients were died within 6 months of follow up. Hence, 42 patients were available for the study including 26 men and 16 women. The mean age was 61 years (range, 35 -90). Clinical evaluation was done using Harris hip score. The position of the blade in the femoral head was evaluated using Cleveland zones and tip apex distance. The fracture reduction was assessed using the Garden Alignment Index and postoperative fracture gap (mm) measurement.Results:The mean follow up period was 15.3 months (range, 9-27). Excellent to good results were accounted for 78% of cases according to Harris hip score. No cases of cut out or breakage of the implant noted. Implant removal was done in 2 patients due to persistent anterior thigh pain.Conclusion:We recommend PFNA II for fixation of unstable intertrochanteric fractures with less operative time and low complication rate. However, proper operative technique is important for achieving fracture stability and to avoid major complications.


2020 ◽  
Author(s):  
Ping Zhen ◽  
Yanfeng Chang ◽  
Heng Yue ◽  
Hui Chen ◽  
Shenghu Zhou ◽  
...  

Abstract BackgroundDorr Type C femoral bone exhibits a wide, stovepipe-shaped femoral canal and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation.MethodsA total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m 2 (range, 16.8-23.2 kg/m 2 ). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index≤3).ResultsThe mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0-4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up.ConclusionsBased on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with Type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Chunxiao Wang ◽  
Yao Zhang ◽  
Xiaojie Tang ◽  
Haifei Cao ◽  
Qinyong Song ◽  
...  

Abstract Background The area which located at the medial pedicle, posterior vertebral body and ventral hemilamina is defined as the hidden zone. Surgical management of hidden zone lumbar disc herniation (HZLDH) is technically challenging due to its difficult surgical exposure. The conventional interlaminar approach harbors the potential risk of post-surgical instability, while other approaches consist of complicated procedures with a steep learning curve and prolonged operation time. Objective To introduce microscopic extra-laminar sequestrectomy (MELS) technique for treatment of hidden zone lumbar disc herniation and present clinical outcomes. Methods Between Jan 2016 to Jan 2018, twenty one patients (13 males) with HZLDH were enrolled in this study. All patients underwent MELS (19 patients underwent sequestrectomy only, 2 patients underwent an additional inferior discectomy). The nerve root and fragment were visually exposed using MELS. The operation duration, blood loss, intra- and postoperative complications, and recurrences were recorded. The Visual Analog Scale (VAS), Oswestry Disability Index (ODI), and the modified MacNab criteria were used to evaluate clinical outcomes. Postoperative stability was evaluated both radiologically and clinically. Results The mean follow-up period was 20.95 ± 2.09 (18–24) months. The mean operation time was 32.43 ± 7.19 min and the mean blood loss was 25.52 ± 5.37 ml. All patients showed complete neurological symptom relief after surgery. The VAS and ODI score were significantly improved at the final follow-up compared to those before operation (7.88 ± 0.70 vs 0.10 ± 0.30, 59.24 ± 10.83 vs 11.29 ± 3.59, respectively, p < 0.05). Seventeen patients (81%) obtained an “excellent” outcome and the remaining four (19%) patients obtained a “good” outcome based the MacNab criteria. One patient suffered reherniation at the same level one year after the initial surgery and underwent a transforaminal endoscopic discectomy. No major complications and postoperative instability were observed. Conclusions Our observation suggest that MELS is safe and effective in the management of HZLDH. Due to its relative simplicity, it comprises a flat surgical learning curve and shorter operation duration, and overall results in reduced disturbance to lumbar stability.


Vision ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 34
Author(s):  
Ronald M. Sánchez-Ávila ◽  
Edmar Uribe-Badillo ◽  
Carlos Fernández-Vega González ◽  
Francisco Muruzabal ◽  
Borja de la Sen-Corcuera ◽  
...  

This study aimed to investigate the use of Plasma Rich in Growth Factors (PRGF) associated with tissue ReGeneraTing Agent (RGTA) drops for the treatment of noninfectious corneal ulcers. RGTA treatment was applied (one drop every two days); however, if ulcer closure was not achieved, PRGF eye drops treatment was added (four times/day). The time taken to reach the ulcer closure, the Best Corrected Visual Acuity (BCVA), intraocular pressure (IOP), Visual Analog Scale (VAS, in terms of frequency and severity of symptoms), and Ocular Surface Disease Index (OSDI) were evaluated. Seventy-four patients (79 eyes) were included, and the mean age was 56.8 ± 17.3 years. The neurotrophic corneal ulcer was the most frequent disorder (n = 27, 34.2%), mainly for herpes virus (n = 15, 19.0%). The time of PRGF eye drops treatment associated with the RGTA matrix was 4.2 ± 2.2 (1.5–9.0) months, and the follow-up period was 44.9 ± 31.5 months. The ulcer closure was achieved in 76 eyes (96.2%). BCVA, VAS and OSDI improved from the baseline (p < 0.001), and IOP remained unchanged (p = 0.665). RGTA and PRGF in noninfectious ulcers were effective and could be a therapeutic alternative for this type of corneal disease.


2021 ◽  
Vol 49 (6) ◽  
pp. 030006052110285
Author(s):  
Kai Xiao ◽  
Bo Xu ◽  
Lin Ding ◽  
Weiguang Yu ◽  
Lei Bao ◽  
...  

Objective To assess the outcomes of traditional three-dimensional (3D) printing technology (TPT) versus mirror 3D printing technology (MTT) in treating isolated acetabular fractures (IAFs). Methods Consecutive patients with an IAF treated by either TPT or MTT at our tertiary medical centre from 2012 to 2018 were retrospectively reviewed. Follow-up was performed 1, 3, 6, and 12 months postoperatively and annually thereafter. The primary outcome was the Harris hip score (HHS), and the secondary outcomes were major intraoperative variables and key orthopaedic complications. Results One hundred fourteen eligible patients (114 hips) with an IAF (TPT, n = 56; MTT, n = 58) were evaluated. The median follow-up was 25 months (range, 21–28 months). At the last follow-up, the mean HHS was 82.46 ±14.70 for TPT and 86.30 ± 13.26 for MTT with a statistically significant difference. Significant differences were also detected in the major intraoperative variables (operation time, intraoperative blood loss, number of fluoroscopic screenings, and anatomical reduction number) and the major orthopaedic complications (loosening, implant failure, and heterotopic ossification). Conclusion Compared with TPT, MTT tends to produce accurate IAF reduction and may result in better intraoperative variables and a lower rate of major orthopaedic complications.


2019 ◽  
Vol 101-B (5) ◽  
pp. 502-511 ◽  
Author(s):  
S. Lidder ◽  
D. J. Epstein ◽  
G. Scott

Aims Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. Materials and Methods A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties. Results A total of 28 studies were eligible for inclusion. This included 5322 hips in 4657 patients with a mean age of 59 years (13 to 94). The mean follow-up was 6.1 years (0.5 to 20). The mean Harris Hip Score improved from 46 (0 to 100) to 92 (39 to 100). The mean Oxford Hip Score improved from 25 (2 to 42.5) to 35 (12.4 to 48). The mean Western Ontario & McMaster Universities Osteoarthritis Index improved from 54 (2 to 95) to 22 (0 to 98). Components were aligned in a neutral coronal alignment in up to 90.9% of cases. A total of 15 studies reported component survivorship, which was 98.6% (92% to 100%) at a mean follow-up of 12.1 years. Conclusion Short-stemmed femoral implants show similar improvement in clinical and radiological outcomes compared with conventional length implants. Only mid-term survivorship, however, is known. An abundance of short components have been developed and used commercially without staged clinical trials. Long-term survival is still unknown for many of these components. There remains tension between innovation and the moral duty to ensure that the introduction of new implants is controlled until safety and patient benefit are demonstrated. Implant innovation and subsequent use should be driven by proven clinical outcomes, rather than market and financial forces, and ethical practice must be ensured. Cite this article: Bone Joint J 2019;101-B:502–511.


Cartilage ◽  
2021 ◽  
pp. 194760352110219
Author(s):  
Danielle H. Markus ◽  
Anna M. Blaeser ◽  
Eoghan T. Hurley ◽  
Brian J. Mannino ◽  
Kirk A. Campbell ◽  
...  

Objective The purpose of the current study is to evaluate the clinical and radiographic outcomes at early to midterm follow-up between fresh precut cores versus hemi-condylar osteochondral allograft (OCAs) in the treatment of symptomatic osteochondral lesions. Design A retrospective review of patients who underwent an OCA was performed. Patient matching between those with OCA harvested from an allograft condyle/patella or a fresh precut allograft core was performed to generate 2 comparable groups. The cartilage at the graft site was assessed with use of a modified Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) scoring system and patient-reported outcomes were collected. Results Overall, 52 total patients who underwent OCA with either fresh precut OCA cores ( n = 26) and hemi-condylar OCA ( n = 26) were pair matched at a mean follow-up of 34.0 months (range 12 months to 99 months). The mean ages were 31.5 ± 10.7 for fresh precut cores and 30.9 ± 9.8 for hemi-condylar ( P = 0.673). Males accounted for 36.4% of the overall cohort, and the mean lesion size for fresh precut OCA core was 19.6 mm2 compared to 21.2 mm2 for whole condyle ( P = 0.178). There was no significant difference in patient-reported outcomes including Visual Analogue Scale, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, and Tegner ( P > 0.5 for each), or in MOCART score (69.2 vs. 68.3, P = 0.93). Conclusions This study found that there was no difference in patient-reported clinical outcomes or MOCART scores following OCA implantation using fresh precut OCA cores or size matched condylar grafts at early to midterm follow-up.