scholarly journals Study on anti-scaling of landfill leachate treated by evaporation method

Author(s):  
Zhongteng Bai ◽  
Yanqiu Wang ◽  
Mingjun Shan ◽  
Yanli Lv ◽  
Guangcai Meng ◽  
...  

Abstract In the mechanical vapor recompression (MVR) treatment of landfill leachate, scaling in the evaporator and heat exchanger poses a serious problem. This study explored the reasons for such scaling and proposed acid or ion-exchange pre-treatments to reduce the alkalinity of the landfill leachate nanofiltration concentrate (LLNC) to prevent scaling. The feasibility of these two methods was evaluated and the technical and economic parameters for application were obtained via experiments. A large amount of HCO3- in the LLNC was the main cause of scaling. The acid addition experiment and field application demonstrated that this method could prevent fouling problems. The cost of acid addition was USD 0.18/t. LLNC pre-treatment by ion-exchange showed that a weakly acidic cation-exchange resin performed better than a strongly acidic cation-exchange resin did. The amount of solid residue under an alkalinity of 0 mg/L could be decreased by 92.9% compared with that of raw LLNC during evaporation. Both methods could alleviate scaling and enable the wide application of the MVR evaporation process in landfill leachate treatment.

1977 ◽  
Vol 23 (10) ◽  
pp. 1921-1924 ◽  
Author(s):  
G J Alexander ◽  
S Machiz

Abstract A convenient screening procedure for presence of drugs of abuse in urine consists of two steps: adsorption of the drugs from urine onto a paper loaded with cation-exchange resin and detection of the adsorbed drugs by direct radioimmunoassay. The first step can be performed in the field, the second in a central laboratory. Storage and transport to the laboratory are simplified because specimens adsorbed on dried paper are stable and can be sent in letter-mail. In the laboratory, a small disc of the ion-exchange paper is exposed to antigen and antibody, rinsed, and tested for radioactivity. Discs treated with positive urines are more radioactive than discs from negative urines.


1980 ◽  
Vol 63 (3) ◽  
pp. 460-461
Author(s):  
Saidul Z Qureshi ◽  
Fadhil M Najib ◽  
Fahmi A Mohammed

Abstract An ion exchange method to determine the alkalinity of water-soluble tea ash containing high levels of manganese is described. A chromatographic column containing a strong cation exchange resin (20–50 mesh) in Na+ form, with a bed volume of 5 mL is used. The present ion exchange method is compared to pH titrations and also to the official AOAC methods (31.012, 31.015, 31.016). Results with the new method are accurate and precise.


2017 ◽  
Vol 92 (7) ◽  
pp. 1678-1689 ◽  
Author(s):  
Pengfei Jiao ◽  
Jinglan Wu ◽  
Yingying Wang ◽  
Jingwei Zhou ◽  
Wei Zhuang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document