scholarly journals Стабильность функциональных характеристик прозрачных электродов на основе трехслойной структуры ZnO : Ga/Ag/ZnO : Ga

Author(s):  
А.Ш. Асваров ◽  
А.К. Ахмедов ◽  
А.Э. Муслимов ◽  
В.М. Каневский

Since to the stability of the functional properties of a transparent conducting three-layer structure ZnO:Ga/Ag/ZnO:Ga is important for practical application, we studied its long-term durability and thermal stability in air environment. It has been demonstrated that after prolonged interaction with the air environment at room temperature (~ 1000 h) and further heat treatment in air at temperatures up to 450 ° C (up to 10 h), the three-layer structure retains its integrity and is characterized by a low sheet resistance Rs = 2.8 Ω/sq at average transmittance in the visible range Tav of 82.1%.

2007 ◽  
Vol 124-126 ◽  
pp. 119-122 ◽  
Author(s):  
Chang Sik Son ◽  
Jae Sung Hur ◽  
Byoung Hoon Lee ◽  
Sang Yul Back ◽  
Jeong Seop Lee ◽  
...  

Multi-component ZnO-In2O3-SnO2 thin films have been prepared by RF magnetron co-sputtering using targets composed of In4Sn3O12(99.99%) [1] and ZnO(99.99%) at room temperature. In4Sn3O12 contains less In than commercial ITO, so that it lowers cost. Working pressure was held at 3 mtorr flowing Ar gas 20 sccm and sputtering time was 30 min. RF power ratio [RF1 / ( RF1 + RF2 )] of two guns in sputtering system was varied from 0 to 1. Each RF power was varied 0~100W respectively. The thicknesses of the films were 350~650nm. The composition concentrations of the each film were measured with EPMA and AES. The low resistivity of 1-2 × 10-3 and an average transmittance above 80% in the visible range were attained for the films over a range of δ (0.3 ≤ δ ≤ 0.5). The films also showed a high chemical stability with time and a good uniformity.


1989 ◽  
Vol 173 ◽  
Author(s):  
Michiya Otani ◽  
Sugio Otani

ABSTRACTThe stability of the magnetic properties of dehydrogenated triaryl-methane resins was investigated both at room temperature and at elevated temperatures. A magnetic property different from that reported in a previous paper was found in the course of studying the reproducibility of synthesis. This new property was examined through a mechanical response of the resins to a set of permanent magnets.


Polymers ◽  
2019 ◽  
Vol 11 (1) ◽  
pp. 176 ◽  
Author(s):  
Wei Dong ◽  
Xuan Wang ◽  
Bo Tian ◽  
Yuguang Liu ◽  
Zaixing Jiang ◽  
...  

Aromatic voltage stabilizers can improve the dielectric properties of cross-linked polyethylene (XLPE); however, their poor compatibility with XLPE hinders their practical application. Improving the compatibility of aromatic voltage stabilizers with XLPE has, therefore, become a new research goal. Herein 1-(4-vinyloxy)phenylethenone (VPE) was prepared and characterized. It can be grafted onto polyethylene molecules during the cross-linking processes to promote stability of the aromatic voltage stabilizers in XLPE. Fourier transform infrared spectroscopy confirmed that VPE was successfully grafted onto XLPE, and effectively inhibited thermal migration. Thermogravimetric analysis showed that the grafted VPE/XLPE composite exhibits a better thermal stability than a VPE/PE blend composite. Evaluation of the electrical properties showed that the breakdown strength and electrical tree initiation voltage of the VPE/XLPE composite were increased by 15.5% and 39.6%, respectively, when compared to those of bare XLPE. After thermal aging, the breakdown strength and electrical tree initiation voltage of the VPE/XLPE composite were increased by 9.4% and 25.8%, respectively, in comparison to those of bare XLPE, which indicates that the grafted voltage stabilizer can effectively inhibit its migration and enhance the stability of the composite material.


2015 ◽  
Vol 816 ◽  
pp. 546-550
Author(s):  
Chao Yuan ◽  
Huan Wang ◽  
Jian Ting Guo ◽  
He Yong Qin

During long-term and high temperature service, microstructures of superalloys may change and then have an adverse impact on mechanical properties, so the stabilities of a wrought Ni-base superalloy aging without stress at 650°C were investigated in this paper. The results showed that the size and morphology of γ' precipitates in the alloy were not obviously influenced with the increase of exposure time, and primary MC carbides present excellent thermal stability. Moreover, almost no detrimental phase was found. Tensile strength and plasticity at room temperature after aging remained steady. Under the condition of 650°C/823MPa, the stress ruptures life presented increasing trend overall and plasticity decreases slightly. In conclusion, the experiment alloy presents a good thermal stability at 650°C.


Materials ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6076
Author(s):  
Ladislav Falat ◽  
Lucia Čiripová ◽  
Viera Homolová ◽  
Miroslav Džupon ◽  
Róbert Džunda ◽  
...  

In this work, the effects of various conditions of short-term rejuvenation heat treatment on room-temperature mechanical properties of long-term aged P92 boiler steel were investigated. Normalized and tempered P92 steel pipe was thermally exposed at 600 °C for time durations up to 5000 h in order to simulate high-temperature material degradation, as also occurring in service conditions. Thus, thermally embrittled material states of P92 steel were prepared, showing tempered martensitic microstructures with coarsened secondary phase precipitates of Cr23C6-based carbides and Fe2W-based Laves phase. Compared with the initial normalized and tempered material condition, thermally aged materials exhibited a slight decrease in strength properties (i.e., yield stress and ultimate tensile strength) and deformation properties (i.e., total elongation and reduction of area). The hardness values were almost unaffected, whereas the impact toughness values showed a steep decrease after long-term ageing. An idea for designing the rejuvenation heat treatments for restoration of impact toughness was based on tuning the material properties by short-term annealing effects at various selected temperatures somewhat above the long-term ageing temperature of P92 material. Specifically, the proposed heat treatments were performed within the temperature range between 680 °C and 740 °C, employing variable heating up and cooling down conditions. It was revealed that short-term annealing at 740 °C for 1 h with subsequent rapid cooling into water represents the most efficient rejuvenation heat treatment procedure of thermally aged P92 steel for full restoration of impact toughness up to original values of normalized and tempered material state. Microstructural observations clearly indicated partial dissolution of the Laves phase precipitates to be the crucial phenomenon that played a key role in restoring the impact toughness.


2020 ◽  
Vol 30 (2) ◽  
pp. 234-241
Author(s):  
Lara Milevoj Kopcinovic ◽  
Marija Brcic ◽  
Jelena Culej ◽  
Marijana Miler ◽  
Nora Nikolac Gabaj ◽  
...  

Introduction: Our aim was to investigate the stability of clinically relevant analytes in pleural and peritoneal fluids stored in variable time periods and variable storage temperatures prior to analysis. Materials and methods: Baseline total proteins (TP), albumin (ALB), lactate dehydrogenase (LD), cholesterol (CHOL), triglycerides (TRIG), creatinine (CREA), urea, glucose and amylase (AMY) were measured using standard methods in residual samples from 29 pleural and 12 peritoneal fluids referred to our laboratory. Aliquots were stored for 6 hours at room temperature (RT); 3, 7, 14 and 30 days at - 20°C. At the end of each storage period, all analytes were re-measured. Deviations were calculated and compared to stability limits (SL). Results: Pleural fluid TP and CHOL did not differ in the observed storage periods (P = 0.265 and P = 0.170, respectively). Statistically significant differences were found for ALB, LD, TRIG, CREA, urea, glucose and AMY. Peritoneal fluid TP, ALB, TRIG, urea and AMY were not statistically different after storage, contrary to LD, CHOL, CREA and glucose. Deviations for TP, ALB, CHOL, TRIG, CREA, urea and AMY in all storage periods tested for both serous fluids were within the SL. Deviations exceeding SL were observed for LD and glucose when stored for 3 and 7 days at - 20°C, respectively. Conclusions: TP, ALB, CHOL, TRIG, CREA, urea and AMY are stable in serous samples stored up to 6 hours at RT and/or 30 days at - 20°C. Glucose is stable up to 6 hours at RT and 3 days at - 20°C. The stability of LD in is limited to 6 hours at RT.


1977 ◽  
Vol 23 (7) ◽  
pp. 1275-1280 ◽  
Author(s):  
H Baadenhuijsen ◽  
H E Seuren-Jacobs ◽  
A P Jansen

Abstract The merits of the vanadomolybdate method in the determination of inorganic phosphate are highly underestimated with regard to the simplicity of the method and the stability of both the reagents and the color that is formed. The absorption curve of the phosphovanadomolybdate complex, with its maximum at 335 nm, extends into the visible range of the spectrum. This permits measurements with inexpensive tungsten-lamp colorimeters. On-stream dialysis is best done in a nitric acid medium, 0.15 mol/liter. Paralleled by the change in the H2PO4-/H3PO4 ratio, appreciable protein binding and poor dialysis efficiency are seen at lower acid concentrations (pH greater than 1.0). Optimum reaction-mixture concentrations of vanadium and molybdenum appeared to be respectively 0.2 and 5 mmol/liter up to 3 mmol of phosphate per liter, in a final acid medium of 0.2 mol/liter, concentrations considerably lower than those used in some studies published earlier. Color development with the stable combined reagent is complete after only 20 s at room temperature and the color is stable for at least 2 h. Figures on precision and accuracy demonstrate the reliability of the method.


2018 ◽  
Vol 29 (1) ◽  
pp. 94-111 ◽  
Author(s):  
Tomás Barranco ◽  
Asta Tvarijonaviciute ◽  
Damián Escribano ◽  
Fernando Tecles ◽  
José J Cerón ◽  
...  

Introduction: In this report, we aimed to examine the stability of various analytes in saliva under different storage conditions. Materials and methods: Alpha-amylase (AMY), cholinesterase (CHE), lipase (Lip), total esterase (TEA), creatine kinase (CK), aspartate aminotransferase (AST), lactate dehydrogenase (LD), lactate (Lact), adenosine deaminase (ADA), Trolox equivalent antioxidant capacity (TEAC), ferric reducing ability (FRAS), cupric reducing antioxidant capacity (CUPRAC), uric acid (UA), catalase (CAT), advanced oxidation protein products (AOPP) and hydrogen peroxide (H2O2) were colorimetrically measured in saliva obtained by passive drool from 12 healthy voluntary donors at baseline and after 3, 6, 24, 72 hours, 7 and 14 days at room temperature (RT) and 4 ºC, and after 14 days, 1, 3 and 6 months at – 20 ºC and – 80 ºC. Results: At RT, changes appeared at 6 hours for TEA and H2O2; 24 hours for Lip, CK, ADA and CUPRAC; and 72 hours for LD, Lact, FRAS, UA and AOPP. At 4 ºC changes were observed after 6 hours for TEA and H2O2; 24 hours for Lip and CUPRAC; 72 hours for CK; and 7 days for LD, FRAS and UA. At – 20 ºC changes appeared after 14 days for AST, Lip, CK and LD; and 3 months for TEA and H2O2. At – 80 ºC observed changes were after 3 months for TEA and H2O2. Conclusions: In short-term storage, the analytes were more stable at 4 ºC than at room temperature, whereas in long-term storage they were more stable at - 80 ºC than at – 20 ºC.


2019 ◽  
Vol 55 (3) ◽  
pp. 188-192
Author(s):  
M. L. Colsoul ◽  
A. Breuer ◽  
N. Goderniaux ◽  
J. D. Hecq ◽  
L. Soumoy ◽  
...  

Background and Objective: Infusion containing lorazepam is used by geriatric department to limit anxiety disorders in the elderly. Currently, these infusions are prepared according to demand by the nursing staff, but the preparation in advance in a centralized service could improve quality of preparation and time management. The aim of this study was to investigate the long-term stability of this infusion in polypropylene syringes stored at 5 ± 3°C. Then, results obtained were compared with stability data of lorazepam in syringes stored at room temperature, glass bottles at 5 ± 3°C, and glass bottles at room temperature. Method: Eight syringes and 6 bottles of infusion were prepared by diluting 1 mL lorazepam 4 mg in 23 mL of NaCl 0.9% under aseptic conditions. Five syringes and 3 bottles were stored at 5 ± 3°C and 3 syringes and 3 bottles were stored at room temperature for 30 days. During the storage period, particle appearance or color change were periodically checked by visual and microscope inspection. Turbidity was assessed by measurements of optical density (OD) at 3 wavelengths (350 nm, 410 nm, 550 nm). The stability of pH was also evaluated. The lorazepam concentrations were measured at each time point by high-performance liquid chromatography with ultraviolet detector at 220 nm. Results: Solutions were physically unstable in syringes at 5 ± 3°C after 4 days: crystals and a drop of OD at 350 nm were observed. However, pH was stable. After 2 days, solutions were considered as chemically unstable because a loss of lorazepam concentration higher than 10% was noticed: the lower 1-sided confidence limit at 95% was below 90% of the initial concentration. To assess temperature and polypropylene influence, results were compared with those obtained for syringes at room temperature and bottles at 5 ± 3°C and room temperature. Precipitation, drop of OD at 350 nm, and chemical instability were observed in all conditions. Conclusion: Solutions of lorazepam were unstable after 2 days in syringes at 5 ± 3°C. Preparation in advance appears, therefore, not possible for the clinical use. Storage conditions (temperature and form) do not improve the stability.


Sign in / Sign up

Export Citation Format

Share Document