scholarly journals Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method

2021 ◽  
Vol 21 (5) ◽  
pp. 1180
Author(s):  
Sekar Ayu Pawestri ◽  
Akhmad Kharis Nugroho ◽  
Endang Lukitaningsih ◽  
Purwantiningsih Purwantiningsih

Pharmacokinetics studies of domperidone generally analyze plasma matrix samples. The present work aimed to develop and validate a rapid and simple reversed phase-HPLC method for quantifying domperidone in plasma matrices. The chromatographic method implemented: 1. Luna Phenomenex® C18 (250 mm × 4.6 mm i.d; 5 µm) column, 2. isocratic mobile phase mixture of phosphate buffer 0.02 M:acetonitrile (70:30, v/v) with a flow rate of 1 mL/min, 3. UV detection at 285 nm. Domperidone and propranolol hydrochloride (as internal standard) were extracted from the deproteinated plasma sample. The method linearity was 0.998 in the range concentration of 15–200 ng/mL. The percentage of accuracy error was between -8.49–4.31%, while the percentage coefficient variation of precision ranged between 5.11–14.24%. This proposed method was simple, rapid (separation time less than 10 min), and selective. The validation parameters responses satisfied the method's requirements to determine domperidone in a plasma sample.

2016 ◽  
Vol 99 (2) ◽  
pp. 481-488 ◽  
Author(s):  
Junjian Ran ◽  
Huadi Sun ◽  
Mingming Zhu ◽  
Juan Chen ◽  
Ruixiang Zhao

Abstract A method based on a reversed-phase HPLC method was established, optimized, and validated for the separation and quantitation of 10 polyphenols extracted from the peel of apple species. A bidentate reversed-phase C18 column was used as stationary phase, and an acidified water buffer and methanol were used as mobile phase. The polyphenols were well separated and detected using UV at 280 and 320 nm. Validation parameters, such as linearity, LOD, LOQ, accuracy, and precision, were acceptable for all 10 polyphenols. The proposed method has enough linearity with correlation coefficient >0.99 within the investigated range for all tested polyphenols. The LOD was 0.24 μg/mL for ellagic acid and <0.2 μg/mL for all other polyphenols. The LOQ was 9.39 × 10−2 μg/mL for chlorogenic acid, and ellagic acid, 2.82 × 10−2 μg/mL for caffeic acid and >0.1 μg/mL for all other polyphenols. Recovery was within the acceptable range from 98.38 to 100.39% for all polyphenols standards. Satisfactory precision was achieved for both intra- and interday assay, with RSD <2%. The method was successfully applied for simultaneous analysis of polyphenols from apple peel.


2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Miteshkumar Acharya ◽  
Cesar A. Lau-Cam

A simple reversed-phase HPLC method for measuring hepatic levels of acetaminophen- (APAP-) protein adduct following an overdose of APAP was developed. An aliquot of liver homogenate in phosphate-buffered saline pH 7.4 (PBS) was placed on a Nanosep centrifugal device, which was centrifuged to obtain a protein residue. This residue was incubated with a solution ofp-aminobenzoic acid (PABA), the internal standard, and bacterial protease in PBS, transferred to a Nanosep centrifugal device, and centrifuged. A 100 μL portion of the filtrate was analyzed on a YMC-Pack ODS-AMQ C18 column, using 100 mM potassium dihydrogen phosphate-methanol-acetic acid (100 : 0.6 : 0.1) as the mobile phase, a flow rate of 1 mL/min, and photometric detection at 254 nm. PABA and APAP-cystein-S-yl (APAP-Cys) eluted at~14.7 min and 22.7 min, respectively. Method linearity, based on on-column concentrations of APAP-Cys, was observed over the range 0.078–40 μg. Recoveries of APAP-Cys from spiked blank liver homogenates ranged from~83% to 91%. Limits of detection and of quantification of APAP-Cys, based on column concentrations, were 0.06 μg and 0.14 μg, respectively. RSD values for interday and intraday analyses of a blank liver homogenate spiked with APAP-Cyst at three levels were, in all cases, ≤1.0% and <1.5%, respectively. The proposed method was found appropriate for comparing the antidotal properties of N-acetylcysteine and taurine in a rat model of APAP poisoning.


1990 ◽  
Vol 36 (1) ◽  
pp. 5-8 ◽  
Author(s):  
J G Goddard ◽  
G J Kontoghiorghes

Abstract "High-performance" liquid-chromatographic (HPLC) methods have been developed for identifying 1-substituted 2-alkyl-3-hydroxypyrid-4-one iron chelators in serum and urine. Ion pairing with heptane- or octanesulfonic acid in pH 2.0-2.2 phosphate buffer and reversed-phase chromatography were required to separate these compounds from endogenous compounds in both biological fluids. In both the 2-methyl and 2-ethyl series of 1-substituted compounds (H, methyl, ethyl, or propyl) the elution times increased in accordance with the n-octanol/water partition coefficients (propyl greater than ethyl greater than H greater than methyl). Urine samples were filtered (0.4 microns pore size) and injected either undiluted or after dilution with elution buffer. After the addition of internal standard, the plasma or serum samples were deproteinized by treatment with HCIO4, 0.5 mol/L, centrifuged, and the supernates were injected directly onto the HPLC. Using these procedures, we could identify 1,2-dimethyl-3-hydroxypyrid-4-one (L1) in the serum and urine of a thalassemic patient who had received a 3-g dose of the drug and in the urine of other patients who had received the same dose. One or more possible metabolites were also observed in the chromatograms of both urine and serum. The 24-h urinary output of L1 (0.22-2.37 g) and iron (10.6-71.5 mg) varied but there was no correlation between the two with respect to quantity or concentration. Instead, urinary iron output was higher in patients with a greater number of transfused units of erythrocytes. This is the first study in humans to show that L1 is absorbed from the gut, enters the circulation, and is excreted in the urine.


2013 ◽  
Vol 5 (19) ◽  
pp. 5010 ◽  
Author(s):  
Marco Ciulu ◽  
Roberta Farre ◽  
Ignazio Floris ◽  
Valeria M. Nurchi ◽  
Angelo Panzanelli ◽  
...  

2011 ◽  
Vol 8 (1) ◽  
pp. 340-346 ◽  
Author(s):  
Rajesh M. Kashid ◽  
Santosh G. Singh ◽  
Shrawan Singh

A reversed phase HPLC method that allows the separation and simultaneous determination of the preservatives methyl paraben (M.P.) and propyl paraben (P.P.) is described. The separations were effected by using an initial mobile phase of water: acetonitrile (50:50) on Inertsil C18 to elute P.P. and M.P. The detector wavelength was set at 205 nm. Under these conditions, separation of the two components was achieved in less than 10 min. Analytical characteristics of the separation such as precision, specificity, linear range and reproducibility were evaluated. The developed method was applied for the determination of preservative M.P. and P.P. at concentration of 0.01 mg/mL and 0.1 mg/mL respectively. The method was successfully used for determining both compounds in sucralfate suspension.


Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 59-68
Author(s):  
H Mahajan ◽  
S Savale ◽  
P Nerkar ◽  

The present study was aimed at developing a Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of curcumin (CRM) and gefitinib (GFT) in bulk, plasma and brain homogenate. hydrochlorothiazide was used as an internal standard (IS). A new simple, rapid, selective, precise and accurate RP-HPLC method has been developed. The separation was achieved by using C-18 column (Qualisil BDS C18, 250 mm x 4.6 mm I.D.) coupled with a guard column of silica, mobile phase consisted of acetonitrile: water with 0.1% formic acid (30:70 v/v). The flow rate was 0.2 ml/min and the drug was detected using PDA detector at the wavelength of 242 nm. The experimental conditions, including the diluting solvent, mobile phase composition, column saturation and flow rate, were optimised to provide high-resolution and reproducible peaks. The method was developed and tested for linearity range of 10-60 μg/mL for bulk analysis and 200-800 ng/mL for plasma and brain homogenate. The developed method was validated as per ICH guidelines, in terms of linearity, application of the proposed method to bulk sample, recovery, precision, repeatability, ruggedness, sensitivity (LOD and LOQ) and robustness and stability study (short and long-term stabilities, freeze/thaw stability, post-preparative). The low value of % RSD showed that the method was precise within the acceptance limit of 2%. The developed method was successfully applied for the analysis of the drug in bulk as well as various marketed formulation and drug in plasma and brain distribution studies.


Sign in / Sign up

Export Citation Format

Share Document