scholarly journals ALTERATION OF PHARMACOKINETIC PARAMETERS OF PROTON PUMP INHIBITORS USING TRANSDERMAL DRUG DELIVERY SYSTEM

Author(s):  
M. R. SHIVALINGAM ◽  
ARUL BALASUBRAMANIAN ◽  
KOTHAI RAMALINGAM

Objective: The present study was aimed to find out the effect of transdermal patches of proton pump inhibitors pantoprazole and esomeprazole on the alteration of pharmacokinetic parameters of these drugs. Methods: The transdermal patches were formulated by the solvent evaporation technique using polymers HPMC E5 with PVP K 30 and HPMC E5 with Eudragit L100 in different ratios. The best formulation from each of the drug pantoprazole and esomeprazole was selected and administered to rabbits and the plasma drug concentration was compared with the marketed formulation. The pharmacokinetic parameters such as maximum plasma concentration (Cmax), time to reach Cmax (tmax), area under the curve (AUC), area under first moment curve (AUMC), elimination rate constant (λz), biological half-life (t1/2), and mean residence time (MRT) were determined. Results: The plasma drug concentration vs time curve shows the extended-release of the drugs pantoprazole and esomeprazole when compared with the marketed formulation. The results show that there is no change in the peak plasma concentration, but a significant difference was observed in all the pharmacokinetic parameters. The AUC showed 6 fold increase for pantoprazole from 8.91 to 55.20 μg*h/ml and 3.5 fold increase for the drug esomeprazole from 7.86 to 28.53 μg*h/ml, and the mean residence time also showed 2 fold increase for the transdermal patches when compared with the marketed formulations. Conclusion: The increase in tmax, AUC, and MRT values of the formulated transdermal patches with the values of the marketed formulation of both the drugs, revealed that the transdermal patches can be used to deliver the drug for an extended period and also can alter the pharmacokinetics of pantoprazole and esomeprazole.

Author(s):  
GNANASEKARAN JOHN SELVARAJ ◽  
ARUL BALASUBRAMANIAN ◽  
KOTHAI RAMALINGAM

Objective: The present study was aimed to alter the pharmacokinetic parameters of the drug pentoxifylline using a novel natural mucoadhesive polymer from two different plants, Manilkara zapotta Linn and Ocimum basilicum Linn. Methods: The polymer was isolated and six batches of mucoadhesive tablets of pentoxifylline was formulated with 3 different concentrations of each polymer. The best formulation from each of the polymer was selected and administered to rabbits and the plasma drug concentration was compared with the marketed formulation. The pharmacokinetic parameters such as such as Cmax, tmax, AUC, AUMC, λz, t1/2, and MRT were determined. Results: The plasma drug concentration vs time curve shows the extended-release of pentoxifylline when compared with the conventional marketed formulation. The results show that there is no change in the peak plasma concentration, but the significant difference was observed in t½, which showed approximately 2.5 fold increase from 2.44 to 6.87 h and the AUC showed five-fold increase from 22.40 to 117.19 μg*h/ml, and other pharmacokinetic parameters, when compared with the marketed formulation. Conclusion: The isolated polymer from the plants Manilkara zapotta Linn. and Ocimum basilicum Linn can be used as a carrier for developing mucoadhesive formulations and it alter the pharmacokinetic of pentoxifylline positively.


Author(s):  
Hamzah Maswadeh ◽  
Ahmed A. H. Abdellatif ◽  
A. Amin Mohammed ◽  
Aiman Y. Alwadi ◽  
A. Ibrahim Mohamed

The aim of this study was to predict the blood/plasma drug concentration profiles for five brand of nifedipine present on the Saudi Arabia market by using the numerical convolution method and to estimate the pharmacokinetic parameters (Cmax, Tmax, Ka, K and Vd) by the application of the residual method to the predicted plasma drug concentration profiles. Results showed that the higher Cmax was 118.95ng/ml for brand A2 and the lower Cmax was 72.29ng/ml for brand A3. The Tmax was ranged from 2.3 hr to 4.9 hr for brands A2 and A3 respectively. The total area under plasma drug concentration curve (AUCinf.) was in lower value equal to 585.59 ng x hr/ml for brand A2 and the higher value was for brand A5 equal to 743.52ng x hr/ml. The volume of distribution was also increased from 52.5 L for free nifidipine to 72 L for brand A1. The predicted first order elimination rate constant was decreased from 0.34 hr-1 for free nifedipine to 0.17 hr-1 for brand A3. The half-life of nifedapine was increased from 2 hours for free drug to 3.93 hours for brand A3. From this study it can be concluded that brands present in the market that shows similarity in accordance to the Dissimilarity factor f1 are not always guaranty that they will be bioequivalent in vivo and vice versa. Also, this study indicates that the method of convolution is a useful tool for prediction of bioequivalence of different brands present on the market.


Author(s):  
MONA IBRAHIM EL-ASSAL

Objective: The study was designed to prepare Nano-sponge formulation loaded with nifedipine. Studying parameters which affecting the formulas in addition to pharmacokinetics and toxicity tests. Methods: Nine Nano-sponge formulations were prepared by the solvent evaporation technique. Different ratios of polymer ethylcellulose, CO-polymers β-cyclodextrin and hydroxypropyl β-cyclodextrin in addition to solubilizing agent polyvinyl alcohol were used. Thermal analysis, X-ray powder diffraction (XRPD), shape and surface morphology, particle size, %production yield, %porosity, % swelling, and % drug entrapment efficiency of Nano-sponge were examined. Release kinetic also studied beside comparison of pharmacokinetic parameters of the optimum choice formula and marketed one in addition to Toxicological consideration. Results: Particle size in the range of 119.1 nm to 529 nm which were increased due to the increase in the concentration of polymer to the drug. Nano-sponge revealed porous, spherical nature. Increased in the drug/polymer molar ratios (1:1 to 1:3) may increase their % production yield ranged from 62.1% to 92.4%. The drug content of different formulations was in the range of 77.9% to 94.7%, and entrapment efficiency was in the range of 82.72 % to 96.63%. Drug released in controlled sustained pattern and followed Higuchi, s diffusion mechanism. Pharmacokinetic parameters of optimized formula showed significant higher maximum plasma drug concentration, area under plasma concentration-time curve, volume of distribution and mean residence time. Nano-sponge loaded drug proved biological safety at low concentrations. Conclusion: Nano-sponge drug delivery system has showed small Nano size, porous with controlled drug release and significant-high plasma drug concentration that improved solubility, drug bioavailability and proved safety.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Qiao Wang ◽  
Wenjin Liu ◽  
Junjun Wang ◽  
Hong Liu ◽  
Yong Chen

Abstract In this study, daidzein long-circulating liposomes (DLCL) were prepared using the ultrasonication and lipid film-hydration method. The optimized preparation conditions by the orthogonal design was as follows: 55 to 40 for the molar ratio of soybean phosphatidylcholine (SPC) to cholesterol, 1 to 10 for the mass ratio of daidzein to total lipid (SPC and cholesterol) (w:w), the indicated concentration of 5% DSPE-mPEG2000 (w:w), 50 °C for the hydration temperature, and 24 min for the ultrasonic time. Under these conditions, the encapsulation efficiency and drug loading of DLCL were 85.3 ± 3.6% and 8.2 ± 1.4%, respectively. The complete release times of DLCL in the medium of pH 1.2 and pH 6.9 increased by four- and twofold of that of free drugs, respectively. After rats were orally administered, a single dose of daidzein (30 mg/kg) and DLCL (containing equal dose of daidzein), respectively, and the MRT0−t (mean residence time, which is the time required for the elimination of 63.2% of drug in the body), t1/2 (the elimination half-life, which is the time required to halve the plasma drug concentration of the terminal phase), and AUC0−t (the area under the plasma drug concentration-time curve, which represents the total absorption after a single dose and reflects the drug absorption degree) of daidzein in DLCL group, increased by 1.6-, 1.8- and 2.5-fold as compared with those in the free group daidzein. Our results indicated that DLCL could not only reduce the first-pass effect of daidzein to promote its oral absorption, but also prolong its mean resident time to achieve the slow-release effect.


2020 ◽  
Vol 3 ◽  
pp. 251581632092118 ◽  
Author(s):  
Abhijeet Jakate ◽  
Ramesh Boinpally ◽  
Matthew Butler ◽  
Kaifeng Lu ◽  
Kristi Womack ◽  
...  

Background: Ubrogepant is a novel, oral calcitonin gene–related peptide receptor antagonist approved by the US Food and Drug Administration for acute treatment of migraine with or without aura in adults. Objectives: To assess potential pharmacokinetic (PK) drug–drug interactions in healthy participants and inform the safety and tolerability of ubrogepant alone and in combination with acetaminophen or nonsteroidal anti-inflammatory drugs (NSAIDs) in healthy participants and participants with migraine. Methods: Two phase 1, three-way crossover studies randomized healthy adults to 100 mg ubrogepant alone, 1000 mg acetaminophen or 500 mg naproxen alone, and 100 mg ubrogepant plus 1000 mg acetaminophen or 500 mg naproxen. Geometric mean ratios (GMRs) and 90% confidence intervals were calculated based on statistical comparison of maximum plasma drug concentration ( C max) and area under the plasma drug concentration–time curve (AUC) for treatment in combination versus alone. Two phase 3 randomized trials included adults with migraine. Treatment-emergent adverse events (TEAEs) were evaluated. Results: Time to C max and terminal elimination half-life for all treatments were unchanged when coadministered. Ubrogepant C max and AUC increased by approximately 40% when coadministered with acetaminophen. Acetaminophen C max decreased by 24% (GMR = 0.76) when coadministered with ubrogepant. There were no significant PK interactions between ubrogepant and naproxen. TEAE rates in the acetaminophen and NSAID rescue medication groups were similar to ubrogepant alone. Conclusions: Coadministration of ubrogepant and acetaminophen resulted in a statistically significant increase in ubrogepant exposure and a decrease in acetaminophen C max; however, these changes were not clinically relevant. No statistically or clinically relevant changes in PK were associated with ubrogepant and naproxen coadministration. No safety concerns were identified for ubrogepant alone or in combination with acetaminophen or NSAIDs.


1988 ◽  
Vol 22 (4) ◽  
pp. 317-323 ◽  
Author(s):  
Peter Gal

Therapeutic drug monitoring has been applied in several patient populations to promote safer, more effective use of drugs. The development of therapeutic ranges allows clinicians to aim for a plasma drug concentration that is usually safe and effective, and calculation of specific pharmacokinetic parameters allows selection of doses that will achieve the desired plasma concentration. This concept certainly holds true in the intensive care nursery; however, the intensity of monitoring in this setting provides opportunities for far broader application of the information obtained from drug concentration monitoring. This review provides an overview of the complexity of and potential applications for therapeutic drug monitoring in neonates based on literature and clinical experience.


Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 2275-2275
Author(s):  
Jonathan Douxfils ◽  
François Mullier ◽  
Christian Chatelain ◽  
Bernard Chatelain ◽  
Dogné Jean-Michel

Abstract Abstract 2275 Introduction: Apixaban is direct factor-Xa inhibitor that reached the market for the prevention of venous thromboembolism in patients undergoing major orthopaedic surgery. It is also being evaluated in the reduction of recurrent ischemic events when added to antiplatelet therapy after an acute coronary syndrome and in the prevention of stroke in patients with non-valvular atrial fibrillation. Thanks to its predictable pharmacokinetic profile, biological monitoring is not required. Nevertheless, evaluation of plasma drug concentration may be valuable in specific situations such as recurrent thrombosis, bleedings, before urgent surgery, in case of bridging and in case of at least two risk factors among the following ones: drug interactions with caution, moderate renal impairment and moderate hepatic impairment; Monitoring may also be useful in infants, pregnant women or in extreme body weights, although no relevant data on drug levels associated with approximate therapeutic and harmful ranges are currently available. Material and Methods: Apixaban was spiked at increasing concentrations (0, 5, 10, 20, 50, 100, 200 and 500 ng/mL) in pooled citrated normal human platelet poor plasma (PPP) to measure Prothrombin Time (PT) and dilute PT with different thromboplastin, Thrombin Generation Assay (TGA) with different inducers and activity on different anti-Xa chromogenic assays. Activated Partial Thromboplastin Time with different reagents, Thrombin Time (TT), Ecarin Clotting Time (ECT) and Reptilase Time (RT), measurement of fibrinogen (Clauss method and PT-derived method) and antithrombin (anti-IIa and anti-Xa based chromogenic assays) were also tested. We also evaluated the impact of apixaban on assays used for the determination of lupus anticoagulant such as the DRVV-T.. (Screen and Confirm) as well as the PTT-LA.. and the Staclot-LA.. . Results and Discussion: As mentioned in previous studies, PT showed a weak sensitivity towards apixaban in comparison with the plasma range obtained in short pharmacokinetic studies. Indeed, the concentration needed to double the clotting time was 154 ng/mL with the most sensitive reagent while the mean Cmax obtained in a short PK study after one oral intake of 5 mg apixaban (dose given in atrial fibrillation) was 96 ng/mL. Therefore, the sensitivity of PT is not strong enough to allow accurate quantitative measurement of the plasma drug concentration (Table 1). Activated Partial Thromboplastin Time presented a better sensitivity but showed a plateau after 100 ng/mL reflecting the uselessness of this test for the quantification of apixaban. Thrombin Time, ECT and RT were logically not affected while DRVV-T.. showed a sensitivity of 205 ng/mL (Screen), which is once again not enough sensitive. On the opposite, chromogenic anti-Xa assays seemed to be very sensitive (Figure 2 and Table 1). Nevertheless, the relation was not always linear and some methodologies needed to be adapted to ensure a broader range of application. TGA (Figure 1) may be useful to assess the pharmacodynamics effects of apixaban on the coagulation process. Nevertheless, the turn around time and the lack of standardisation are currently limitations that restrict the use of this method. In the case of the exploration of an haemorrhagic event, specific tests such as RT, fibrinogen (Clauss and PT-derived method (dFib)), TT and clotting factor activity may be used. Apixaban did not interfere with these tests. Antithrombin determination if also of importance and chromogenic anti-IIa based assays should be used in face of patients treated with apixaban to avoid misdiagnosis since an overvaluation of 12% by 100 ng/mL was shown using one chromogenic anti-Xa based assay. Conclusion: PT may not be used as screening test to assess the risk of bleedings. A more specific and sensitive assay such as chromogenic anti-Xa assays using calibrators should be used to correctly assess the concentration of apixaban. Determination of lupus anticoagulant using DRVV-T.. and PTT-LA.. or Staclot LA.. as well as the determination of antithrombin using factor-Xa based chromogenic assays, were influenced by apixaban. Finally, standardization of the time between the last intake of apixaban and the sampling is mandatory. Figures: Disclosures: No relevant conflicts of interest to declare.


2010 ◽  
pp. n/a-n/a ◽  
Author(s):  
Takahide Uchimura ◽  
Motohiro Kato ◽  
Tomohisa Saito ◽  
Haruki Kinoshita

Sign in / Sign up

Export Citation Format

Share Document