scholarly journals Pseudotumor Associated with Dall-Miles Cable Breakage Following Revision Total Hip Arthroplasty: A Case Report

2021 ◽  
Vol 17 (3) ◽  
pp. 187-192
Author(s):  
Se Won Oh ◽  
Seung Yun Jee ◽  
Seong Oh Park

A pseudotumor is a benign granulomatous or cystic lesion associated with the deposition of metal debris in joint arthroplasties. To the best of our knowledge, this is the first report on a pseudotumor caused by the breakage of the Dall-Miles cable grip system, a multifilament cable used to fix the trochanteric osteotomy in revision total hip arthroplasty. This rare case demonstrates that pseudotumor formation can be caused by various types of orthopedic materials and implant components. When encountering a palpable mass around an orthopedic implant, a pseudotumor should be considered along other differential diagnoses. To treat pseudotumors and also prevent recurrence, its complete resection and sufficient removal of orthopedic materials are necessary.

2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


2021 ◽  
pp. 112070002110043
Author(s):  
Antonios A Koutalos ◽  
Sokratis Varitimidis ◽  
Konstantinos N Malizos ◽  
Theofilos Karachalios

Purpose: The aim of the study was to systematically evaluate clinical outcomes of tapered fluted stems, either monoblock or modular, in revision total hip arthroplasty. Methods: PubMed, EMBASE and Web of Science and Cochrane databases were systematically searched by 2 researchers. Clinical studies reporting primarily on survival and re-revision rates, and secondarily on subsidence, dislocation, intraoperative fractures, periprosthetic fractures and infection were included. 2 investigators assessed the quality of the studies. Results: 46 studies were included in this review, reporting on 4601 stem revisions. The pooled re-revision rate was 5.1% and long-term survival ranged from 75% to 98.5%. No differences were observed between monoblock and modular stems regarding re-revision rate, dislocation rate, periprosthetic fracture rate or infection rates. Monoblock stems exhibited more subsidence and modular stems displayed more intraoperative fractures. Conclusions: Satisfactory results can be obtained with the use of tapered fluted end-bearing stems. Monoblock stems offer the same clinical results as modular stems.


Author(s):  
Lauren N Pearson ◽  
Robert L Schmidt ◽  
Kenneth Cahoon ◽  
Christopher E Pelt

Abstract Background Total nucleated cell (TNC) count and differential are used to classify joint effusions as inflammatory or noninflammatory. Further diagnostic evaluation and management is contingent on this classification. TNC count can be measured by automated analyzers or by manual assessment using a hemocytometer. Studies have raised concerns regarding the accuracy of TNC counts measured by automated instruments, particularly in the setting of joint arthroplasty. The objective of this study was to determine whether metallosis, a complication of total hip arthroplasty in which metal debris accumulates in periprosthetic tissues and synovial fluid, is associated with inaccurate TNC counts in synovial fluid. Methods We compared the accuracy of cell counts measured by the Sysmex XN-1000 and Beckman Coulter Iris iQ200 with the gold standard of manual assessment using a hemocytometer in synovial fluid from patients with suspected metallosis and in fluid obtained from controls from patients with native joints and a history of arthroplasty for other indications. Results TNC counts produced by automated analyzers were associated with increased levels of discordance (relative to manual counts) in patients with metallosis. Metallosis was not associated with increased levels of discordance for RBC counts or WBC differentials. The Sysmex XN flagged all but 1 metallosis sample for manual verification of the results. Conclusions Automated methods are generally reliable for analysis of synovial fluid. TNC counts can be inaccurate in the context of metallosis following total hip arthroplasty. Laboratories should correlate automated cell counts with a microscopic assessment of the specimen, as recommended by instrument manufacturers.


2008 ◽  
Vol 90 (4) ◽  
pp. 881-884 ◽  
Author(s):  
Lindsey S. Hagstrom ◽  
Dennis J. Callahan ◽  
James W. Green

2012 ◽  
Vol 14 (1) ◽  
pp. 39-49 ◽  
Author(s):  
Eduardo García-Rey ◽  
Ricardo Fernández-Fernández ◽  
David Durán ◽  
Rosario Madero

2009 ◽  
Vol 24 (2) ◽  
pp. e19
Author(s):  
Kevin J. Bozic ◽  
Steven M. Kurtz ◽  
Edmund Lau ◽  
Kevin Ong ◽  
Thomas P. Vail ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document