scholarly journals RAW WATER QUALITY ANALYSIS TO DISCOVER THE CAUSE OF PIPELINE SCALLING PROBLEM IN PT. X (ICE PRODUCTION COMPANY)

Author(s):  
Kadek Diana Harmayani ◽  
Gede Adi Wiguna Sudiartha ◽  
I Wayan Budiarsa Suyasa

<span id="docs-internal-guid-36e28651-7fff-038c-0ab0-ffb60a635785"><span>PT. X is one of the ice companies in which its largest company is located in Bali, more precisely in the Pidada area, North Denpasar. Based on field observations the area is an area that has a calcareous soil structure. The water source of PT. X was extracted from the groundwater. From the field observation, it was found that the pipeline network, that connected the inlet water to water treatment system and ice production units, was severely covered by faint white scale. In order to discover the origin of this scale, water quality testing need to be carried out.  From the results, it was found that the total hardness in the inlet water, taken from the groundwater tap, was 162.85 mg/l with calcium concentration of 2.15 mg/l and iron 3.83 mg/l. Water quality testing was also carried out in the water treatment unit consisting of resin softener where the total hardness surprisingly increased into 279.81 mg/l, calcium concentration was 2.96 mg/l, iron concentration was 0.55 mg/l. Even after being treated in softener resin, the total hardness increased sharply to 483 mg/l, which categorized as extreme hardness. The increase in total hardness indicates that there was a failure in the operation of the water treatment system, even it also contributed to the higher hardness and calcium concentration. This over-year’s treatment failure has been causing accumulation of hardness and calcium concentration in the compartment of both water treatment system and ice production unit that inflicts a higher hardness level in the effluent.</span></span>

2018 ◽  
Vol 18 (1) ◽  
pp. 107-115 ◽  
Author(s):  
Kwang-Hee Lee ◽  
◽  
Min-Ho Kim ◽  
Nam-Woo An ◽  
Chul-hwi Park

Water ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 258 ◽  
Author(s):  
Huasheng Zou ◽  
Haoyuan Tang

The existing traditional drinking water disinfection technology relies mainly on chlorine disinfection alone, which has high disinfection efficiency and can effectively inactivate most of the microorganisms in the water. However, it produces a series of harmful disinfection by-products (DBPs). Therefore, it is very necessary to study an efficient and environmentally friendly disinfection technology for drinking water. For this purpose, a novel continuous-flow ultrasound (US)/chlorination water treatment system was designed and developed. Escherichia coli (E. coli), Bacillus subtilis (B. subtilis), and Staphylococcus aureus (S. aureus) were selected as indicators of water treatment effects to (1) investigate the disinfection effects of different bacteria by US treatment alone at different single or dual frequencies; (2) explore the disinfection effects of US pretreatment with 8 mg/L NaClO on different bacteria to assess the promoting effects of US pretreatment; and (3) identify the optimum system process to satisfy the national standard for drinking water quality. Results showed that the dual-frequency US had better inactivation effects compared with single-frequency US, although it could not achieve an ideal disinfection level (complete disinfection). Further, 17 + 33 kHz dual-frequency US pretreatment had obvious enhancement of the disinfection efficiency, where 3.85 (E. coli), 3.65 (S. aureus), and 3.52 (B. subtilis) log reduction were achieved when 8 mg/L NaClO disinfection lasted 10 min, and finally all three bacteria achieved 4 log reduction after 30 min. Moreover, the treated water satisfied the Chinese national standard for drinking water quality, in which the residual chlorine concentration was below 4 mg/L. The utilization efficiency of disinfectant was improved approximately 40% by 17 + 33 kHz US pretreatment.


Water ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 867
Author(s):  
Zejin Zhang ◽  
Wei Zhang ◽  
Xi Hu ◽  
Kexin Li ◽  
Pengfei Luo ◽  
...  

Rural China faces a shortage of safe drinking water. There are significant challenges associated with small centralized water supply systems and decentralized water supply systems. Many rural residents use point-of-use water treatment systems to ensure the safety of their drinking water. The actual water purification effect and applicability of these water treatment systems in small centralized and decentralized water supply systems need to be determined urgently. In this study, the water quality index (WQI) method was applied for the first time in rural areas to evaluate the effectiveness of point-of-use water treatment systems. A total of 67 reverse osmosis water treatment systems were tested. The rate of compliance with drinking water standards of the decentralized water supply was low (37%). Compared with untreated water, the use of a reverse osmosis water treatment system improved the rate of compliance with drinking water standards, but this effect was not satisfactory (8%). Among the factors potentially affecting the purified water quality of point-of-use water treatment systems (e.g., service time of the water treatment system, service time of the filter element, and type of water source), the service time of the filter element had the most significant influence on the water quality. If the filter element had not been replaced for a long period, the removal effect of the water treatment system on the total hardness, sulfide, copper, and ammonia nitrogen was significantly affected, reducing the quality of the purified water. To ensure the safety of drinking water, it is recommended to replace the filter element of a reverse osmosis water treatment system at least once a year.


1988 ◽  
Vol 20 (11-12) ◽  
pp. 117-123 ◽  
Author(s):  
D. van der Kooij ◽  
W. A. M. Hijnen

A K.pneumoniae strain, isolated from a water treatment system, was tested in growth measurements for its ability to multiply at substrate concentrations of a few micrograms per liter. The organism multiplied on mixtures of carbohydrates and amino acids at a substrate concentration of 1 µg of C of each compound per liter. Tests with individual compounds revealed that especially carbohydrates were utilized at low concentrations. The Ks values obtained for maltose and maltopentaose were 53 µg of C/l and 114 µg of C per liter, respectively. The significance of the growth of K.pneumoniae at low substrate concentrations is discussed.


Author(s):  
Hongsik Yoon ◽  
Jiho Lee ◽  
Taijin Min ◽  
Gunhee Lee ◽  
Minsub Oh

Capacitive deionization (CDI) has been highlighted as a promising electrochemical water treatment system. However, the low deionization capacity of CDI electrodes has been a major limitation for its industrial application,...


RSC Advances ◽  
2021 ◽  
Vol 11 (32) ◽  
pp. 19788-19796
Author(s):  
Bramha Gupta ◽  
Rushikesh S. Ambekar ◽  
Raphael M. Tromer ◽  
Partha Sarathi Ghosal ◽  
Rupal Sinha ◽  
...  

The impact of micro and nanoplastic debris on our aquatic ecosystem is among the most prominent environmental challenges we face today.


Sign in / Sign up

Export Citation Format

Share Document