scholarly journals Development of a Comprehensive HPLC Method for Determination of Product-related Impurities and Assay of Active Ingredients in Papaverine Hydrochloride Products

Author(s):  
N. P. Antonova ◽  
E. P. Shefer ◽  
N. E. Semenova ◽  
S. S. Prokhvatilova ◽  
A. M. Kalinin ◽  
...  

Abstract. Papaverine hydrochloride products are used as anticonvulsants in routine medical practice. Most of the approved product specification files include thin-layer chromatography for assessment of product-related impurities and UV spectrophotometry for determination of active pharmaceutical ingredients. An HPLC assay is not used for determination of papaverine hydrochloride in drug dosage forms.The aim of the study was to develop an HPLC test method for determination of product-related impurities and for quantification of papaverine hydrochloride in solutions for injection, tablets, and rectal suppositories.Materials and methods: samples of the following Russian-made papaverine products were used in the study: Papaverine, solution for injection, 20 mg/mL; Papaverine, rectal suppositories, 20 mg; Papaverine, tablets, 40 mg. The Agilent 1260 Infinity II DAD System was used for the HPLC assay, and the Agilent 8453Е UV-Vis System was used for recording UV spectra. The determination of product-related impurities and the assay of active ingredients were performed simultaneously by HPLC using a reversed-phase column Kromasil 100-5-C18, 250×4.6 mm, 5 μm, the gradient elution mode, and detection at        238 nm. Papaverine Hydrochloride USP RS, 99% purity, and Noscapine EP CRS were used as reference standards.Results: the study demonstrated that determination of product-related impurities and assay of active ingredients in papaverine products can be performed simultaneously using HPLC.Conclusions: the authors proposed an HPLC test method for determination of active ingredients in papaverine products, which is aligned with the “consistent standardisation” principle and can be recommended for inclusion into draft monographs for papaverine products.

2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
Vita Giaccone ◽  
Giuseppe Polizzotto ◽  
Andrea Macaluso ◽  
Gaetano Cammilleri ◽  
Vincenzo Ferrantelli

The aim of our present work was the development of a rapid high-performance liquid chromatography method with electrospray ionization and tandem mass spectrometry detection (LC-ESI-MS/MS) for the determination of several corticosteroids in cosmetic products. Corticosteroids are suspected to be illegally added in cosmetic preparations in order to enhance the curative effect against some skin diseases. Sample preparation step consists in a single extraction with acetonitrile followed by centrifugation and filtration. The compounds were separated by reversed-phase chromatography with water and acetonitrile (both with 0.1% formic acid) gradient elution and detected by ESI-MS positive and negative ionization mode. The method was validated at the validation level of 0.1 mg kg−1. Linearity was studied in the 5–250 μg L−1 range and linear coefficients (r2) were all over 0.99. The accuracy and precision of the method were satisfactory. The LOD ranged from 0.085 to 0.109 mg kg−1 and the LOQ from 0.102 to 0.121 mg kg−1. Mean recoveries for all the analytes were within the range 91.9–99.2%. The developed method is sensitive and useful for detection, quantification, and confirmation of these corticosteroids in cosmetic preparations and can be applied in the analysis of the suspected samples under investigation.


2011 ◽  
Vol 30 (2) ◽  
pp. 139 ◽  
Author(s):  
Ana Petkovska ◽  
Hristina Babunovska ◽  
Marina Stefova

Quality control of pharmaceuticals requires development of fast, efficient and reliable methods for determination of active compounds as well as known and very often unknown impurities within defined concentration ranges. In this work, a simple and rapid HPLC-UV-DAD method for identification and quantification of pholcodine process related impurities and some degradation products was developed and validated. Pholcodine and its five structural analogues such as morphine, codeine, thebaine, oripavine, and papaverine were separated in less than 10 minutes using reversed phase LiChrospher C-8 column. For optimal chromatographic performance with reproducible retention times, gradient elution with 2% ammonium hydroxide in water and acetonitrile was used. The method was validated by establishing its selectivity, specifity, sensitivity, linearity, intra- and inter-day precision and robustness. All tested parameters confirmed that the method is suitable for determination of pholcodine and its five impurities in pharmaceutical drug samples. The results obtained from real sample analysis give support to the suitability of the proposed method for the purpose of quality control.


1997 ◽  
Vol 80 (4) ◽  
pp. 751-755 ◽  
Author(s):  
Theresa A Gehring ◽  
Larry G Rushing ◽  
Harold C Thompson

Abstract Fourteen sulfonamides—sulfanilamide, sulfadiazine, sulfathiazole, sulfapyridine, sulfam- erazine, sulfamethazine, sulfamethizole, sulfamethoxypyridazine, sulfachloropyridazine, sulfamonomethoxine, suļfadoxine, sulfamethoxazole, sulfadimethoxine, and sulfaquinoxoline—residues of which could be found in aquacultured species, were separated in <25 min by reversed-phase (C18) liquid chromatography (LC) with gradient elution. Analytes were extracted from edible salmon tissue (muscle and adhering skin) with acetonitrile—2% aqueous acetic acid, isolated with 2 liquid-liquid partitionings, and derivatized with fluorescamine after eluting from the column. The derivatives were detected by fluorescence. Recoveries (n = 4) from coho salmon fortified with sulfonamides at 5,10, and 20 ng/g tissue averaged 79.7± 7.3, 84.6 ± 7.7, and 88.2 ± 7.1%, respectively. Limits of quantitation were 5 ng/g tissue, for sulfanilamide, sulfamethoxypyridazine, and sulfaquinoxoline and 1 ng/g tissue for the remaining sulfonamides.


1998 ◽  
Vol 44 (7) ◽  
pp. 1481-1488 ◽  
Author(s):  
Maria Shipkova ◽  
Paul Dieter Niedmann ◽  
Victor William Armstrong ◽  
Ekkehard Schütz ◽  
Eberhard Wieland ◽  
...  

Abstract We describe a reversed-phase HPLC method for determination of total mycophenolic acid (MPA), its free concentration (MPAf), and the glucuronide metabolite (MPAG), based on simple sample preparation and gradient elution chromatography. The compounds were quantified in parallel by absorbance at 254 nm and 215 nm in the internal standard mode. Linearity was verified up to 50 mg/L for MPA and up to 500 mg/L for MPAG (r >0.999). Detection limits at 215 and 254 nm were, respectively, 0.01 and 0.03 mg/L for MPA, and 0.03 and 0.1 mg/L for MPAG. The recovery of MPA was 95–106%;recovery of MPAG was 96–106%. The imprecision (CV) for MPA (0.2–25 mg/L) was <8.4% (254 nm) and <4.4% (215 nm) within day (n = 12) and <9.2% (254 nm) and <6.2% (215 nm) between days (n = 12). The imprecision for MPAG (10–250 mg/L) was <4.9% (254 nm) and <3.4% (215 nm) within day, and <6.1% (254 nm) and <5.9% (215 nm) between days. For quantification of MPAf, 100 μL of ultrafiltrate was applied directly to the column. The detection limit was 0.005 mg/L at 215 nm and 0.015 mg/L at 254 nm. In the range between 18–210 μg/L, the within-day CVs were <11.8% (n = 12) and the between-day CVs were <15.8% (n = 12).


1987 ◽  
Vol 33 (9) ◽  
pp. 1585-1592 ◽  
Author(s):  
W A MacCrehan ◽  
E Schönberger

Abstract We describe a method for the determination of retinol, alpha-tocopherol, and beta-carotene in serum, using a liquid-chromatographic separation with wavelength-programmed ultraviolet/visible absorbance and amperometric electrochemical detection with a glassy carbon electrode. After protein denaturation and addition of an internal standard, tocol, 250-microL samples are twice extracted with hexane. The reversed-phase, gradient-elution chromatographic separation provides baseline resolution of: the all-trans isomer of retinol from the cis isomers, alpha- from gamma-tocopherol, and all-trans-beta-carotene from alpha-carotene and from cis-beta-carotene isomers. The linearity of response and the detection limits for the two detectors for the three analytes are measured. A comparison of the values obtained for serum extracts shows good agreement between the absorbance and electrochemical detectors.


2010 ◽  
Vol 93 (5) ◽  
pp. 1503-1514 ◽  
Author(s):  
Sumita Dixit ◽  
Subhash K Khanna ◽  
Mukul Das

Abstract A simple and sensitive HPLC method has been developed for the simultaneous determination of eight permitted food colors and five commonly encountered nonpermitted colors in various food commodities, including sugar-, fat-, and starch-based food matrixes. The method uses a specific food category-based cleanup/treatment procedure before color extraction to avoid the interference of food matrixes, and to obtain the optimal color extraction. Analysis was performed on a reversed-phase C18 -Bondapak column with ammonium acetate and acetonitrile gradient elution as the mobile phase; a programmable max-specific visible detection was used to monitor colors to obtain the higher sensitivity and expanded scope needed for multicolor blends having diverse absorption maxima. All colors showed good linearity, with regression coefficients of 0.99740.9999. The LOD and LOQ values ranged from 0.01 to 0.12 mg/L, and from 0.04 to 0.83 mg/L or mg/kg, respectively. The intraday and interday precision tests produced good RSD values, and the recoveries from different food matrixes ranged from 82 to 104%. The method offers high sensitivity for analysis of a wide variety of food matrixes containing a broad scope of multicolor blends. Two nonpermitted colors, orange II and metanil yellow, were found. Also, a number of samples contained permitted colors at levels two-to seven-fold higher than those prescribed.


Author(s):  
Roman Kand'ár ◽  
Pavla Žáková

Abstract: Uric acid is the final product of purine metabolism in humans. It was determined that this compound has important antioxidative properties and it may be oxidized to allantoin by various reactive oxygen species. Therefore, the measurement of allantoin may be useful for the determination of oxidative stress in humans.: We measured allantoin and uric acid in human plasma and erythrocytes obtained from patients with chronic renal failure before hemodialysis (n=30) and blood donors (n=30). We used a method based on selective isolation of allantoin from deproteinized plasma and erythrocyte lysate samples on AG 1-X8 resin and its derivatization to glyoxylate-2, 4-dinitrophenylhydrazone. Separation of glyoxylate-2, 4-dinitrophenylhydrazone from interfering substances was achieved on reversed phase HPLC with gradient elution and UV/VIS detection at 360 nm. Uric acid was determined by reversed phase HPLC with UV/VIS detection at 292 nm.: We found significant differences in allantoin and uric acid concentration between the patients with chronic renal failure and the control group both in plasma (20.5±6.5 μmol/L and 323.9±62.9 μmol/L vs. 2.1±1.1 μmol/L and 270.1±62.3 μmol/L, p<0.05) and erythrocytes [82.8±39.1 nmol/g hemoglobin (Hb) and 110.7±28.8 nmol/g Hb vs. 20.1±6.1 nmol/g Hb and 82.1±23.7 nmol/g Hb, p<0.05].: Significant higher levels of allantoin in both plasma and erythrocytes of patients with chronic renal failure indicate that allantoin may be used as a good marker of oxidative stress.Clin Chem Lab Med 2008;46:1270–4.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Sonoube Kombath ◽  
Issa-Bella Balde ◽  
Sandra Carret ◽  
Sofiane Kabiche ◽  
Salvatore Cisternino ◽  
...  

A stability-indicating method was validated for the determination in pharmaceutical forms of idebenone a coenzyme Q10-like compound. The assay was achieved by liquid chromatography analysis using a reversed-phase C18 column and a detector set at 480 nm. The optimized mobile phase consisted of isocratic flow rate at 1.0 mL/min for 3 min with methanol. The linearity of the assay was demonstrated in the range of 3.0 to 8.0 mg/mL with a correlation coefficientr2>0.998. The limits of detection and quantification were 0.03 and 0.05 mg/mL, respectively. The intraday and interday precisions were less than 1.0%. Accuracy of the method ranged from 98.6 to 101.5% with RSD < 0.6%. Specificity of the assay showed no interference from tablets components and breakdown products formed by alkaline, acidic, oxidative, sunlight, and high temperature conditions. This method allows accurate and reliable determination of idebenone for drug stability assay in pharmaceutical studies.


Sign in / Sign up

Export Citation Format

Share Document