scholarly journals Determination of methyl mercury and total mercury in sediment samples collected from canals in HoChiMinh city

2016 ◽  
Vol 19 (4) ◽  
pp. 123-136
Author(s):  
Hien Thai Hoang ◽  
Dong Van Nguyen

In this study, the analysis of methyl mercury (MeHg) and total mercury (T-Hg) was studied using gas chromatographic separation/atomic fluorescence spectrometric detection and cold vapour atomic absorption spectrometry respectively. MeHg was extracted from sediment matrix using HNO3/KCl/CuSO4 into dichloromethane followed ethylation with NaB(C2H5)4 in hexane. Total mercury was digested using three different procedures: EPA 245.1, AOAC 971.21 and our proposed one. The reliability of the analytical method for MeHg was evaluated by the use of the certified reference material ERM CC-580. In addition, the analytical method for total merury was evaluated using a fresh water sediment as an internal reference material, spiked with inorganic mercury, methyl mercury and phenyl mercury. The method detection limits for MeHg and total mercury were 0.08 and 0.15 ng/g (as Hg), respectively. The established analytical methods were applied to analyse MeHg and total mercury in sediment samples collected from canals and rivers in Hochiminh City. The concentrations of methyl mercury and total mercury in sediment samples were 0.08–2.87 ng/g và 14 – 623 ng/g (as Hg, dw). [MeHg]/Σ[Hg] respectirely were in a range of 0.1–2.3 %, which was in good agreement with the published ratios in sediment samples. A good correlation between the concentration of MeHg with total mercury and total organic carbon contents in the studied sediment samples was found.

2018 ◽  
Vol 1 (3) ◽  
pp. 31 ◽  
Author(s):  
Ahmed Elezz ◽  
Hassan Mustafa Hassan ◽  
Hamood Abdulla Alsaadi ◽  
Ahmed Easa ◽  
Saeed Al-Meer ◽  
...  

A method for the measurement of total mercury (T-Hg) in environmental samples using cold vapour atomic absorption spectrometry (CV AAS) has been validated yielding a dynamic range (0.04–10.00 μg/kg) and high certified reference material (CRM) recovery (>90%). The validation was carried out according to International Union of Pure and Applied Chemistry (IUPAC) validation and Eurachem Guides. A freeze-dried and homogenised sample was weighed and then digested using Suprapur acids (HNO3, H2SO4, and HF) with potassium dichromate solution in a hot block digestion system. A calibration curve was constructed (R2 > 0.999). Two CRMs (Marine Sediment Reference Material (PACS-3) and Trace Elements in Muscle Tissue (Trace Elements and Methylmercury in Mussel Tissue (NIST2976)) were utilised for quality assurance and control. The limit of quantification (LOQ) calculated as 0.04 µg/kg, and uncertainty (U) calculated as 2%. The obtained results showed the suitability of this method for direct mercury measurement in environmental samples. Additionally, the proficiency of this method was recognised by accreditation under the standard of International Organization for Standardization (ISO/IEC 17025:2017) for competence of testing and calibration laboratories.


2011 ◽  
Vol 5 (3) ◽  
pp. 505-511 ◽  
Author(s):  
Valderi Luiz Dressler ◽  
Clarissa Marques Moreira Santos ◽  
Fabiane Goldschmidt Antes ◽  
Fabrina Regia Stum Bentlin ◽  
Dirce Pozebon ◽  
...  

2012 ◽  
Vol 29 (4) ◽  
pp. 617-624 ◽  
Author(s):  
A.P. Nascimento Neto ◽  
L.C.S. Magalhães Costa ◽  
A.N.S. Kikuchi ◽  
D.M.S. Furtado ◽  
M.Q. Araujo ◽  
...  

1976 ◽  
Vol 59 (1) ◽  
pp. 153-157
Author(s):  
Jurgen L Kacprzak ◽  
Ramon Chvojka

Abstract A method for the concurrent determination of methyl mercury and inorganic mercury by flameless atomic absorption spectroscopy (AAS) is described. Fifty-seven samples of juvenile black marlin fish were analyzed for inorganic and methyl mercury, and total mercury was calculated by addition of the 2 values. The sensitivity of the method was estimated to be 0.029 μg for inorganic mercury and 0.033 μg for methyl mercury. The detection limit of the method was about 0.02 μg inorganic mercury or methyl mercury and the error of the method was found not to exceed 10% for samples giving about 10% deflection on the absorbance scale. Samples from the same fish were analyzed by a commonly accepted flameless AAS method for the determination of total mercury. When the results for total mercury from the 2 methods were statistically compared, using a paired t-test, the difference between the results obtained by the 2 methods was found to be insignificant at the 95% confidence level.


Sign in / Sign up

Export Citation Format

Share Document