scholarly journals Dental implant displacement into the mandibular body: a case report

2021 ◽  
Vol 10 (13) ◽  
pp. e203101320978
Author(s):  
Gustavo Augusto Grossi-Oliveira ◽  
Stéfany Barbosa ◽  
Eduardo Dallazen ◽  
Ana Maira Pereira Baggio ◽  
Stefani Caroline Ferrioli ◽  
...  

              Posterior mandible region is considered a highly predicable place for primary stability during dental implant placement. Although, this region can present a significant decrease in bone density, which can lead to implant dislocation during insertion. The present case reports an unusual dislocation of dental implant in a 59 old healthy patient's mandible and a secure solution for this kind of complication. During the drilling, bone quality type IV was observed. In sequence, implant was abruptly inserted in the perforation site and dropped into the bone marrow. Panoramic radiograph showed the implant inside bone marrow, close to mandibular base. The implant was removed through the surgical site. The screw of the implant prosthesis transfer was used to reach the displaced implant. A second implant with the same dimensions as the first one, differing by the external hexagon, was inserted into the same implant site. Therefore, the authors strongly recommend the use of the presented technique prior to osteotomy on mandibular body, reserving the second in the impossibility of reaching the internal connection of the displaced implant.

2013 ◽  
Vol 70 (6) ◽  
pp. 586-594 ◽  
Author(s):  
Zoran Vlahovic ◽  
Branko Mihailovic ◽  
Zoran Lazic ◽  
Mileta Golubovic

Background/Aim. Flapless implant surgery has become very important issue during recent years, mostly thanks to computerization of dentistry and software planning of dental implants placements. The aim of this study was to compare flap and flapless surgical techniques for implant placement through radiographic and radiofrequency analyses. Methods. The experiment was made in five domestic pigs. Nine weeks following domestic pigs teeth extraction, implants were placed, on the right side using surgical technique flap, and flapless on the left side. Digital dental Xrays were applied to determine primary dental implant stability quality (ISQ). At certain intervals, not later than three months, the experimental animals were sacrificed, and just before it, control X-rays were applied to measure dental implants stability. Results. Radiographic analysis showed that peri-implant bone resorption in the first 4 weeks following placement implants with flap and flapless surgical techniques was negligible. After the 3 months, mean value of peri-implant bone resorption of the implants placed using flap technique was 1.86 mm, and of those placed using flapless technique was 1.13 mm. In relation to the primary dental implant stability in the first and second week there was an expected decrease in ISQ values, but it was less expressed in the dental implants placed using the flapless technique. In the third week the ISQ values were increased in the dental implants placed by using both techniques, but the increase in flapless implant placement was higher (7.4 ISQ) than in flap implant placement (1.5 ISQ). The upward trend continued in a 4- week period, and after 3 months the dental implant stability values in the implants placed using flap technique were higher than the primary stability for 7.1 ISQ, and in the implants placed using flapless technique were higher comparing to the primary stability for 10.1 ISQ units. Conclusion. Based on the results of radiographic and resonance frequency analyses it can be concluded that the flapless technique in surgical implants placemat, leads to better results.


2019 ◽  
Vol 2019 ◽  
pp. 1-4 ◽  
Author(s):  
Antonio Scarano ◽  
Bartolomeo Assenza ◽  
Francesco Inchingolo ◽  
Filiberto Mastrangelo ◽  
Felice Lorusso

Background. The immediate placement of a dental implant could represent an option treatment for the rehabilitation of a postextractive missing tooth socket to replace compromised or untreatable teeth, with the advantage of single-session surgery. In this way, the anatomy of the alveolar bone defect, the preservation of the buccal cortical bone, and the primary stability of the fixture represent the critical factors that consent a precise implant placement. Objective. This case report describes a novel fixture design for postextractive alveolar socket immediate implant. Methods. Two patients (25 and 31 years old) were treated for postextractive dental implant placement to replace both central upper incisor teeth with four implants. The residual bone implant gap was not filled with graft or bone substitute. The restoration was provided following a standard loading protocol by a cement-sealed prosthetic abutment. Results. Clinically, all implants positioned showed an excellent insertion torque. No postoperative complications were reported. At 6 months of healing, the buccal cortical bone and the implant stability were present and well maintained. Conclusion. The evidence of this study allows us to underline the possible advantages of this new fixture design for postextractive implant technique.


2019 ◽  
Vol 43 (4) ◽  
pp. 356-360
Author(s):  
Eun Joo Choi ◽  
Hyo Joon Kim ◽  
Seong Yong Moon

2014 ◽  
Vol 24 (1) ◽  
pp. 1407-1415 ◽  
Author(s):  
You-Min Huang ◽  
I-Chiang Chou ◽  
Cho-Pei Jiang ◽  
Yi-Syun Wu ◽  
Shyh-Yuan Lee

2019 ◽  
Vol 9 (5) ◽  
pp. 860 ◽  
Author(s):  
Antonio Nappo ◽  
Carlo Rengo ◽  
Giuseppe Pantaleo ◽  
Gianrico Spagnuolo ◽  
Marco Ferrari

Implant stability is relevant for the correct osseointegration and long-term success of dental implant treatments. The aim of this study has been to evaluate the influence of implant dimensions and position on primary and secondary stability of implants placed in maxilla using resonance frequency analysis. Thirty-one healthy patients who underwent dental implant placement were enrolled for the study. A total of 70 OsseoSpeed TX (Astra Tech Implant System—Dentsply Implants; Mölndal, Sweden) implants were placed. All implants have been placed according to a conventional two-stage surgical procedure according to the manufacturer instructions. Bone quality and implant stability quotient were recorded. Mean implant stability quotient (ISQ) at baseline (ISQ1) was statistically significant lower compared to 3-months post-implant placement (ISQ2) (p < 0.05). Initial implant stability was significantly higher with 4 mm diameter implants with respect to 3.5 mm. No differences were observed within maxilla regions. Implant length, diameter and maxillary regions have an influence on primary stability.


2011 ◽  
Vol 37 (sp1) ◽  
pp. 183-191 ◽  
Author(s):  
Gulfem Ergun ◽  
Isil Cekic Nagas ◽  
Dervis Yilmaz ◽  
Mustafa Ozturk

Patients with complete edentulism who have insufficient bone for endosseous dental implant treatment present a challenge for dental practitioners. Distraction osteogenesis of the edentulous alveolar ridges is a process for augmentation of atrophic alveolar bone before dental implant placement. This clinical report describes the use of distraction osteogenesis and rehabilitation of patients with a fixed or removable implant-supported prosthesis to treat mandibular defects. Two female patients with segmental alveolar atrophy at the posterior regions of mandible and one female patient with defect at the anterior region of mandible were treated using distraction devices. However, lingual tipping of the distraction vector occurred during the distraction phase in patient 1. The morphology of the alveolar bone was also analyzed in relation to the planned implant position. After a consolidation period of 12 weeks on average, radiologic observation suggested that there was sufficient bone formation for implant installation. In all patients, implant-supported fixed or removable prosthetic oral rehabilitation was successfully performed, and the clinical and radiologic findings were satisfactory. After 4 years of follow-up, no functional or esthetic difficulties with the implants and restorations were noted. These case reports suggest that although alveolar distraction osteogenesis seems to be an effective technique for augmenting atrophic alveolar bone for creating bone and soft tissue, complications may occur after surgical procedures.


2014 ◽  
Vol 17 (4) ◽  
pp. 125 ◽  
Author(s):  
Maria Ângela Lacerda Esper ◽  
Ana Carolina Salvia ◽  
Maria Tereza Pedrosa Albuquerque ◽  
Nelson Luiz Macedo

<p style="margin: 0cm 0cm 0pt; text-align: justify; line-height: 200%; -ms-text-justify: inter-ideograph;"><span style="line-height: 200%; font-family: 'Arial','sans-serif'; font-size: 12pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US;" lang="EN-US">The aim of this study was to report two cases of orthodontic extrusion performed prior to dental implant placement. The first one reports the case of a 57 year-old-female who presented internal root resorption in the left central incisor, and orthodontic extrusion of this element was indicated. The treatment lasted 24 weeks. At the end of this period, the dental implant was placed. The second clinical event refers to a patient of 66 years of age who had vertical fracture in the left central incisor. In this case, the orthodontic extrusion was conducted in 12 weeks. At the end of this period, the dental implant was placed and also the temporary crown, but without occlusal contact. Both cases reported consisted of the involvement of the left central incisor in the aesthetic area and low bone density. The cases reported demonstrated that orthodontic extrusion is a viable alternative to the aesthetic and functional reconstruction with prosthesis over dental implants.</span></p>


Sign in / Sign up

Export Citation Format

Share Document