scholarly journals Application of Infrared Thermography in an Adequate Reusability Analysis of Photovoltaic Modules Affected by Hail

2022 ◽  
Vol 12 (2) ◽  
pp. 745
Author(s):  
Hrvoje Glavaš ◽  
Matej Žnidarec ◽  
Damir Šljivac ◽  
Nikola Veić

Infrared thermography, in the analysis of photovoltaic (PV) power plants, is a mature technical discipline. In the event of a hailstorm that leaves the PV system without the support of the power grid (and a significant portion of the generation potential), thermography is the easiest way to determine the condition of the modules and revive the existing system with the available resources. This paper presents research conducted on a 30 kW part of a 420 kW PV power plant, and demonstrates the procedure for inspecting visually correct modules that have suffered from a major natural disaster. The severity of the disaster is shown by the fact that only 14% of the PV modules at the test site remained intact. Following the recommendations of the standard IEC TS 62446-3, a thermographic analysis was performed. The thermographic analysis was preceded by an analysis of the I-V curve, which was presented in detail using two characteristic modules as examples. I-V curve measurements are necessary to relate the measured values of the radiation and the measured contact temperature of the module to the thermal patterns. The analysis concluded that soiled modules must be cleaned, regardless of the degree of soiling. The test results clearly indicated defective module elements that would result in a safety violation if reused. The research shows that the validity criterion defined on the basis of the analysis of the reference module can be supplemented, but can also be replaced by a statistical analysis of several modules. The comparison between the thermographic analysis and the visual inspection clearly confirmed thermography as a complementary method for testing PV-s.

2019 ◽  
Vol 2 (S1) ◽  
Author(s):  
Jelenko Karpić ◽  
Ekanki Sharma ◽  
Tamer Khatib ◽  
Wilfried Elmenreich

Abstract The rising demand for sustainable energy requires to identify the sites for photovoltaic systems with the best performance. This paper tackles the question of feasibility of photovoltaic power plants at high altitude. A direct comparison between an alpine and an urban area site is conducted in the south of Austria. Two low-cost automatic photovoltaic power measurement devices with dual-axis sun tracking and maximum power point tracking are deployed at two test sites. The system periodically performs a scan over the southern semihemisphere and executes maximum power point adjustment in order to assess the performance for a given direction. The gathered data shows a higher photovoltaic power yield in the higher altitude test site. Furthermore, the high altitude photovoltaic power as a function of azimuth and elevation angle appears to be not only higher but also more flat than in lower altitudes. This indicates a lower power loss in case of deviation from the optimal solar angles. The results show that even on low-cost hardware a difference in photovoltaic power can be observed, even though in this experiment it amounts to less than 5% increase of peak power in higher altitudes. However, the measured peak powers on the mountain are more stable and therefore closer to a constant level than the heavily fluctuating peak power values at the low altitude site. Additionally, a slight shift in optimal elevation angles between altitudes can be observed, as the optimum angle turns out to be lower on the high altitude site. This angle shift could be caused by snow reflections on the mountainous test site.


1968 ◽  
Vol 25 (7) ◽  
pp. 1441-1452 ◽  
Author(s):  
Joseph D. Richard

A series of tests were conducted to determine the effectiveness of pulsed low-frequency acoustic signals for attracting fishes. The acoustic signals were contrived to simulate the hydrodynamically generated disturbances normally associated with active predation. Underwater television was used to observe fish arrivals during both control and test periods. Demersal predatory fishes were successfully attracted although they habituated rapidly to the acoustic stimulus. Members of the families Serranidae, Lutjanidae, and Pomadasyidae were particularly well represented among the fishes attracted. Sharks were also attracted in considerable numbers. Herbivorous reef fishes, although common around the test site, were not attracted. Possible relationships between the test results and the hearing capabilities of fishes are discussed. It is concluded that acoustic attraction techniques have potential applications in certain existing commercial fisheries.


Author(s):  
Mantosh Kumar ◽  
Kumari Namrata ◽  
Akshit Samadhiya

Abstract As the exhaust rate of the conventional sources has geared up already, this is compelling the power industries to install the power plants based on the non-conventional sources so that future demand of the energy supply can be fulfilled. Among the various sources of renewable energy like wind, hydro, tidal etc., solar energy is the most easily accessible and available renewable energy source. Ensuring the feasibility of any energy source not only technical but also the economical perspective is the most important criteria. This paper has incorporated both the perspective and has done the techno-economic analysis to determine the optimum combination of the PV array size and battery size to minimize the overall electricity generation per unit. In this paper, a standalone solar PV system has been analyzed for the location of Jamshedpur, where an effort has been done to choose the optimum combination of the solar array and battery size within the desired range of LLP so that the electricity generation cost per unit can be minimized. The overall duration of the analysis has been done for a year and the outcome of the research has been verified with the help of MATLAB software.


Coatings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1361
Author(s):  
István Bodnár ◽  
Dávid Matusz-Kalász ◽  
Rafael Ruben Boros ◽  
Róbert Lipták

The Hungarian society and the Hungarian state are constantly increasing their solar capacity. More and more solar power plants are being put into operation. The largest of these has a 100 MW peak capacity. Such power plants do not require constant maintenance. However, in the case of low productivity, a conditional assessment is required. The reason for production loss can also be manufacturing, installation, and operational errors. A flying drone was used for finding failures by thermographic scouting. Furthermore, electroluminescent (EL) and flash tests give a comprehensive view of the real state of the modules in a mobile laboratory. We had the opportunity to summarize these test results of more than a thousand modules operating in a solar power plant. The report on the power plant shows that a significant part of the modules became unusable in a short time. After four years, 10% of the 260 Wp modules suffered a performance reduction of more than 10%.


2020 ◽  
Vol 15 (3) ◽  
Author(s):  
Arvind R S ◽  
Prasanna Ram M ◽  
Prashanth T ◽  
Jaimon Dennis Quadros

Cenosphere fly ash is one of the most inexpensive and low-density material which is abundantly available as a solid waste by-product of coal combustion in thermal power plants. Aluminium metal matrix composites with Nickel coated cenospheres as the reinforcement is prepared by stir casting route. The composites are prepared with varying percentages of cenospheres in the percentage of 2-10% by weight of the composite. Immersion corrosion tests are conducted on the composites in three different medium and for three different time durations. It is evident from the test results as well as the microstructure images that the weight loss of samples with 8% Nickel coated cenospheres has shown least corrosion or the highest corrosion resistance when compared to the counterparts.


2021 ◽  
Vol 297 ◽  
pp. 01051
Author(s):  
Mohammed Agdam ◽  
Abdallah Asbayou ◽  
Mustapha Elyaqouti ◽  
Ahmed Ihlal ◽  
Khaled Assalaou

To respond to the increase in demand for electricity, the use of photovoltaics is growing considerably as it produces electrical energy without polluting the environment. In addition, to enhance the efficiency of photovoltaic modules, an MPPT algorithm is required to follow the maximum voltage and maximum current in the IV curve. This technique can be achieved by using a DC-DC converter. For this purpose, various MPPT techniques have been developed. The combination of MPPT and DC-DC converter is implemented using Matlab/Simulink and connected to a modelled PV module to validate the simulation.


Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 512
Author(s):  
Zhi Cheng ◽  
Xinrong Cheng ◽  
Yuchao Xie ◽  
Zhe Ma ◽  
Yuhao Liu

Desulfurization ash and fly ash are solid wastes discharged from boilers of power plants. Their utilization rate is low, especially desulfurization ash, most of which is stored. In order to realize their resource utilization, they are used to modify loess in this paper. Nine group compaction tests and 32 group direct shear tests are done in order to explore the influence law of desulfurization ash and fly ash on the strength of the loess. Meanwhile, FLAC3D software is used to numerically simulate the direct shear test, and the simulation results and the test results are compared and analyzed. The results show that, with the increase of desulfurization ash’s amount, the shear strength of the modified loess increases first and then decreases. The loess modified by the fly ash has the same law with that of the desulfurization ash. The best mass ratio of modified loess is 80:20. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 12.74% higher than that of the pure loess on average and the shear strength of loess modified by fly ash is 3.59% higher than that of the pure loess on average. The effect of the desulfurization ash on modifying the loess is better than that of the fly ash. When the mass ratio is 80:20, the shear strength of loess modified by the desulfurization ash is 9.15% higher than that of the fly ash on average. Comparing the results of the simulation calculation with the actual test results, the increase rate of the shear stress of the FLAC3D simulation is larger than that of the actual test, and the simulated shear strength is about 8.21% higher than the test shear strength.


POROS ◽  
2021 ◽  
Vol 16 (2) ◽  
pp. 121
Author(s):  
Muhammad Ridwan Ridwan ◽  
Noviyanti Nugraha Nugraha

Biomass power plants are electricity generators with alternative energy that utilize organicmaterials, in this case cow dung. The cow dung is then processed to produce syngas. Syngas is used as fuelto turn turbines. In previous studies, a cow manure gasification reactor was designed and manufactured.This reactor is part of a biomass power plant system (PLTBm) which is made separately. The power outputtarget of this PLTBm is 370 kW. The purpose of this study was to examine the performance of the downdraftreactor of cow dung biomass, namely discharge, temperature, and analyze the gas content released by thereactor so that the power that can be generated by the reactor can be obtained. The test results obtained acombustion chamber temperature of 580°C and a discharge of 0.285 m3/s. The composition of the outputgas is acetylene 58.16%, hexane 27.66%, butane 6.38%, and methane 7.8%. From the calculation results,the power generated by the reactor is 342 kW.


2015 ◽  
Vol 52 (10) ◽  
pp. 1526-1538 ◽  
Author(s):  
Yong-Xia Wu ◽  
Shui-Long Shen ◽  
Ye-Shuang Xu ◽  
Zhen-Yu Yin

This paper presents a case history of the leakage behavior during dewatering tests in the gravel strata of an excavation pit of a metro station in Hangzhou, China. The groundwater system at the test site is composed of a phreatic aquifer underlain by an aquitard and a confined aquifer with coarse sand and gravel. The sandy gravel stratum has very high hydraulic conductivity. The maximum depth of the excavation is 24 m below the ground surface, which reaches the middle of the aquitard strata, where the thickness of the clayey soil is insufficient to maintain the safety of the base of the excavation. To understand the hydrological characteristics of gravel strata, single- and double-well pumping tests were conducted, where a cut-off wall was installed 43 m deep with its base penetrating 2 to 3 m into the aquifer. Test results show that this partial cut-off of the aquifer cannot effectively protect the base of the excavation from the upward seepage force of the groundwater during excavation. Therefore, a new cut-off wall (second phase) was constructed to a depth of 54 m to cut off the confined aquifer. A second pumping test was conducted after the construction of the second phase cut-off wall, and test results show that this full cut-off combined with dewatering can control groundwater effectively during excavation. This finding indicates that when a deep excavation is conducted in a confined aquifer with high hydraulic conductivity, determination of the depth of the retaining wall should be based on three factors: the stability of the base, the upward seepage stability, and settlement control.


2004 ◽  
Author(s):  
David L. Wright ◽  
Theodore H. Asch ◽  
Craig W. Moulton ◽  
David von G. Smith ◽  
S. Raymond Hutton ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document