scholarly journals Experimental Investigation of Adaptive Thermal Comfort in French Healthcare Buildings

Buildings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 551
Author(s):  
Zoubayre El Akili ◽  
Youcef Bouzidi ◽  
Abdelatif Merabtine ◽  
Guillaume Polidori ◽  
Amal Chkeir

The thermal comfort requirements of disabled people in healthcare buildings are an important research topic that concerns a specific population with medical conditions impacted by the indoor environment. This paper experimentally investigated adaptive thermal comfort in buildings belonging to the Association of Parents of Disabled Children, located in the city of Troyes, France, during the winter season. Thermal comfort was evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires adapted to their disability. Indoor environmental parameters such as relative humidity, mean radiant temperature, air temperature, and air velocity were measured using a thermal microclimate station during winter in February and March 2020. The main results indicated a strong correlation between operative temperature, predicted mean vote, and adaptive predicted mean vote, with the adaptive temperature estimated at around 21.65 °C. These findings highlighted the need to propose an adaptive thermal comfort strategy. Thus, a new adaptive model of the predicted mean vote was proposed and discussed, with a focus on the relationship between patient sensations and the thermal environment.

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4530
Author(s):  
Youcef Bouzidi ◽  
Zoubayre El Akili ◽  
Antoine Gademer ◽  
Nacef Tazi ◽  
Adil Chahboun

This paper investigates adaptive thermal comfort during summer in medical residences that are located in the French city of Troyes and managed by the Association of Parents of Disabled Children (APEI). Thermal comfort in these buildings is evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires, while thermal comfort was estimated using the predicted mean vote (PMV) model. Indoor environmental parameters (relative humidity, mean radiant temperature, air temperature, and air velocity) were measured using a thermal environment sensor during the summer period in July and August 2018. A good correlation was found between operative temperature, mean radiant temperature, and PMV. The neutral temperature was determined by linear regression analysis of the operative temperature and Fanger’s PMV model. The obtained neutral temperature is 23.7 °C. Based on the datasets and questionnaires, the adaptive coefficient α representing patients’ capacity to adapt to heat was found to be 1.261. A strong correlation was also observed between the sequential thermal index n(t) and the adaptive temperature. Finally, a new empirical model of adaptive temperature was developed using the data collected from a longitudinal survey in four residential buildings of APEI in summer, and the obtained adaptive temperature is 25.0 °C with upper and lower limits of 24.7 °C and 25.4 °C.


2020 ◽  
Vol 4 (3) ◽  
pp. 261
Author(s):  
Abdul Qodir ◽  
Erni Setyowati ◽  
Suryono Suryono

This study examines the effect of the porch on the adaptive thermal comfort of mosques by taking 2 mosques that have different porch shapes with the specific purpose of obtaining data on the neutrality, acceptability and preferences of the mosque respondents' thermal conditions in the framework of developing adaptive thermal comfort standards for Indonesia. Measurement of physical environment variables is done by taking data on temperature, humidity, air velocity, and mean radiant temperature (MRT) at 2 mosques and at the same time the impression and thermal preference questionnaire data are taken, examination of clothing types and activities, and list of thermal environment controls to 40 respondents in each mosque. Data of thermal neutrality and thermal preferences were analyzed by regression analysis using SPSS 19 software, while thermal acceptance was analyzed based on the results of the questionnaire answers. The analysis showed that the neutrality value at Ulul Albab mosque was Tdb = 28.47 OC, ET * = 30.11 OC, SET * = 23.11 OC, TSENS = 1.17, DISC = -1.06, and PMV = -0.65, this data shows that the neutral condition desired by respondents is slightly below the average condition, while the neutrality in Nurul Ilmi mosque at Tdb = 30.27 OC, ET * = 31.65 OC, SET * = 29.05 OC, TSENS = 1.03, DISC = 1.68, and PMV = 1.22, this data also shows that the neutral conditions desired by respondents are slightly below average conditions. While the preference value at Ulul Albab mosque is Tdb = 22.25 OC, ET * = 28.62 OC, SET * = 24.24 OC, TSENS = 0.23, DISC = 0.23, and PMV = -0.60 and preference conditions at Nurul Ilmi mosque at Tdb = 29.11 OC, ET * = 31.17 OC, SET * = 28.50 OC, TSENS = 1.04, DISC = 1.45, and PMV = 1.03. As many as 92% of respondents in the Ulul Albab mosque can accept local thermal conditions in the temperature range of 27oC - 31oC. While 90% of respondents in the Nurul Ilmi mosque can accept local thermal conditions in the temperature range of 27oC-32oC. The results of the neutrality, acceptance and preference analysis show that the Ulul Albab mosque is better than the Nurul Ilmi mosque.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3712
Author(s):  
Balázs András-Tövissi ◽  
László Kajtár ◽  
Árpád Nyers

In the case of public buildings with ceiling heating and mechanical ventilation, radiant temperature asymmetry caused by the warm ceiling and draught occur simultaneously. The currently available literature does not offer an exhaustive description of the comfort conditions resulting from such a thermal environment. This research focuses on complementing the available knowledge, using instrumental measurements, as well as subject measurements carried out on 20 individuals. Relying on these measurements, the purpose of the research is to support the understanding of the combined mechanisms of action of the two local discomfort parameters. The main result of this research is that, if the predicted percentage dissatified is less than 6%, the radiant temperature asymmetry is in an interval of 5–15 °C, and the draught rate is 15% or 25%, the actual mean vote and the predicted mean vote values differ significantly, and the actual mean vote is always lower, with a few exceptions. In addition, the research highlights the changes of the actual mean vote caused by raising the draught rate from 15% to 25%, in the presence of radiant temperature asymmetry caused by warm ceilings.


2021 ◽  
Vol 13 (7) ◽  
pp. 3614
Author(s):  
Zeyad Amin Al-Absi ◽  
Mohd Isa Mohd Hafizal ◽  
Mazran Ismail ◽  
Azhar Ghazali

Building sector is associated with high energy consumption and greenhouse gas emissions, which contribute to climate change. Sustainable development emphasizes any actions to reduce climate change and its effect. In Malaysia, half of the energy utilized in buildings goes towards building cooling. Thermal comfort studies and adaptive thermal comfort models reflect the high comfort temperatures for Malaysians in naturally conditioned buildings, which make it possible to tackle the difference between buildings’ indoor temperature and the required comfort temperature by using proper passive measures. This study investigates the effectiveness of building’s retrofitting with phase change materials (PCMs) as a passive cooling technology to improve the indoor thermal environment for more comfortable conditions. PCM sheets were numerically investigated below the internal finishing of the walls. The investigation involved an optimization study for the PCMs transition temperatures and quantities. The results showed significant improvement in the indoor thermal environment, especially when using lower transition temperatures and higher quantities of PCMs. Therefore, the monthly thermal discomfort time has decreased completely, while the thermal comfort time has increased to as high as 98%. The PCM was effective year-round and the optimum performance for the investigated conditions was achieved when using 18mm layer of PCM27-26.


2021 ◽  
Vol 8 (1) ◽  
pp. 23
Author(s):  
Erna Meutia ◽  
Laina Hilma Sari

The Gayo Highland is one of the districts in Aceh Province, Sumatra. Due to the topography, this area has a lower  temperature compared than the flat and coastal areas in Aceh. The thermal comfort that is felt is based on a person's mental condition and how he expresses his satisfaction with his thermal environment. In other words, it shows how humans adapt to their thermal environment. Thermal comfort based on human adaptation is known as adaptive thermal comfort. The form of dwelling for the Gayo Highland community has shifted and changed from traditional dwelling to Transitional and Modern forms that influence the Gayo Highland community's adaptation to achieve thermal comfort. Therefore, this paper aims to investigate the house design in Gayo highland in providing warmth to the occupants naturally in the cold environment. Another aim of this study is to investigate the people's habits in warming up the body to deal with the low air temperature in the area.  This study shows how the local people adapt themselves through the house element and daily habit to gain the internal thermal comfort.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2021 ◽  
Vol 20 (1) ◽  
pp. 106-127
Author(s):  
António Manuel Figueiredo Freitas Oliveira ◽  
◽  
Helena Corvacho ◽  

In this paper, some of the results of an experimental study are presented. Its purpose was to better understand the impact of glazing on thermal comfort of users of indoor spaces (living and working), especially in the areas near glazed walls. Glazed elements, such as windows and glazed doors, allow visual access to the outdoor environment and the entrance of natural light and solar heat gains but they are often the cause of unwanted heat losses and gains and are disturbing elements in obtaining thermal comfort, both in global terms and in what concerns local discomfort due to radiant asymmetries and/or air draughts. Furthermore, solar radiation directly affecting users in the vicinity of glazing can also cause discomfort. These disturbances are recognized by users, both on cold winter days and on hot summer days. To assess thermal comfort or thermal neutrality of a person in a particular indoor space, it is important to know their location within that space. Thus, in order to adequately assess thermal comfort in the areas near the glazing, the indoor thermal environment must be characterized for this specific location. In this study, two indoor spaces (a classroom and an office-room) of a school building were monitored at different periods of the year. The measurements of the environmental parameters were performed both in the center of the rooms and in the areas near the glazing. Five models of thermal comfort assessment were then applied to the results, in order to compare the comfort conditions between the two studied locations and to evaluate the applicability of these models to the areas close to glazed walls. It was observed there was clearly a greater variability of comfort conditions in the vicinity of the glazed walls when compared to the center of the rooms. The application of thermal comfort assessment models to the two studied rooms was able to reveal the differences between the two compared locations within each space. It was also possible to show the effect of incoming solar radiation and the influence of the geometry of the spaces and of the ratio between glazed area and floor area by comparing the results for both spaces. The assessment model proposed by LNEC (Portuguese National Laboratory of Civil Engineering) proved to be the most adapted to Portuguese users’ habits.


2019 ◽  
Vol 9 (5) ◽  
pp. 899 ◽  
Author(s):  
Jongseong Gwak ◽  
Motoki Shino ◽  
Kazutaka Ueda ◽  
Minoru Kamata

Thermal factors not only affect the thermal comfort sensation of occupants, but also affect their arousal level, productivity, and health. Therefore, it is necessary to control thermal factors appropriately. In this study, we aim to design a thermal environment that improves both the arousal level and thermal comfort of the occupants. To this end, we investigated the relationships between the physiological indices, subjective evaluation values, and task performance under several conditions of changes in the indoor ambient temperature. In particular, we asked subjects to perform a mathematical task and subjective evaluation related to their thermal comfort sensation and drowsiness levels. Simultaneously, we measured their physiological parameters, such as skin temperature, respiration rate, electroencephalography, and electrocardiography, continuously. We investigated the relationship between the comfort sensation and drowsiness level of occupants, and the physiological indices. From the results, it was confirmed that changes in the indoor ambient temperature can improve both the thermal comfort and the arousal levels of occupants. Moreover, we proposed the evaluation indices of the thermal comfort and the drowsiness level of occupants using physiological indices.


2016 ◽  
Vol 34 (4/5) ◽  
pp. 427-445 ◽  
Author(s):  
Baharuddin Hamzah ◽  
Muhammad Taufik Ishak ◽  
Syarif Beddu ◽  
Mohammad Yoenus Osman

Purpose The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the thermal environment and thermal comfort of respondents in naturally ventilated university classrooms and compare them with the ASHRAE and Indonesian National Standard (SNI); to check on whether the predicted mean vote (PMV) model is applicable or not for predicting the thermal comfort of occupants in naturally ventilated university classrooms; and to analyse the neutral temperature of occupants in the naturally ventilated university classrooms. Design/methodology/approach The study was carried out at the new campus of Faculty of Engineering, Hasanuddin University, Gowa campus. A number of field surveys, which measured thermal environments, namely, air temperature, mean radiant temperature (MRT), relative humidity, and air velocity, were carried out. The personal activity and clothing properties were also recorded. At the same time, respondents were asked to fill a questionnaire to obtain their thermal sensation votes (TSV) and thermal comfort votes (TCV), thermal preference, and thermal acceptance. A total of 118 respondents participated in the study. Before the survey was conducted, a brief explanation was provided to the participants to ensure that they understood the study objectives and also how to fill in the questionnaires. Findings The results indicated that the surveyed classrooms had higher thermal environments than those specified in the well-known ASHRAE standard and Indonesian National Standard (SNI). However, this condition did not make respondents feel uncomfortable because a large proportion of respondents voted within the comfort zone (+1, 0, and −1). The predictive mean vote using the PMV model was higher than the respondents’ votes either by TSV or by TCV. There was a huge difference between neutral temperature using operative temperature (To) and air temperature (Ta). This difference may have been because of the small value of MRT recorded in the measured classrooms. Originality/value The research shows that the use of the PMV model in predicting thermal comfort in the tropic region might be misleading. This is because PMV mostly overestimates the TSV and TCV of the respondents. People in the tropic region are more tolerant to a higher temperature. On the basis of this finding, there is a need to develop a new thermal comfort model for university classrooms that is particularly optimal for this tropical area.


Sign in / Sign up

Export Citation Format

Share Document