scholarly journals Modern Rotational Radiation Techniques with Volumetric Modulated Arc Therapy or Helical Tomotherapy for Optimal Sparing of the Lung and Heart in Left-Breast Cancer Radiotherapy Plus Regional Nodal Irradiation: A Comparative Dosimetric Analysis

Cancers ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 5043
Author(s):  
Pei-Yu Hou ◽  
Chen-Hsi Hsieh ◽  
Le-Jung Wu ◽  
Chen-Xiong Hsu ◽  
Deng-Yu Kuo ◽  
...  

Background: For advanced breast cancer with lymph node involvement, adjuvant radiotherapy (RT) with regional nodal irradiation (RNI) has been indicated to reduce cancer recurrence and mortality. However, an extensive RT volume is associated with normal organ exposure, which increases the toxicity and affects patient outcomes. Modern arc RT techniques can improve normal organ sparing compared with conventional techniques. The aim of this study was to explore the optimal technique for left-breast RT with RNI. Methods: We retrospectively reviewed patients receiving RT with RNI for left-breast cancer. We used modern arc RT techniques with either volumetric-modulated arc therapy (VMAT) or helical tomotherapy (HT) with a novel block technique, and compared differences in dosimetry parameters between the two groups. Subgroup analysis of RNI with or without internal mammary node (IMN) volume was also performed. Results: A total of 108 eligible patients were enrolled between 2017 and 2020, of whom 70 received VMAT and 38 received HT. The median RT dose was 55 Gy. No significant differences were found regarding the surgery, RT dose, number of fractions, target volume, and RNI volume between the VMAT and HT groups. VMAT reduced the heart mean dose more than HT (3.82 vs. 5.13 Gy, p < 0.001), as well as the cardiac parameters of V5-V20, whole-lung mean dose, lung parameters of V5-V20, and contralateral-breast and esophagus mean dose. In the subgroup analysis of RNI with IMNs, the advantage of VMAT persisted in protecting the heart, lung, contralateral breast, and esophagus. HT was beneficial for lowering the thyroid mean dose. For RNI without IMN, VMAT improved the low-dose exposure of the heart and lung, but HT was similar to VMAT in terms of heart, whole-lung, and contralateral-breast mean dose. Conclusions: For patients with left-breast cancer receiving adjuvant RT with RNI, VMAT reduced the exposure dose to the heart, lung, contralateral breast, and esophagus compared with HT. VMAT was superior to HT in terms of normal organ sparing in the patients who underwent RNI with IMN irradiation. Considering the reduction in normal organ exposure and potential toxicity, VMAT is the optimal technique for patients receiving RNI when deep inspiration breath-hold is not available.

2018 ◽  
Vol 13 (1) ◽  
Author(s):  
Pei-Chieh Yu ◽  
Ching-Jung Wu ◽  
Hsin-Hua Nien ◽  
Louis Tak Lui ◽  
Suzun Shaw ◽  
...  

Author(s):  
Reena Phurailatpam ◽  
Tabassum Wadasadawala ◽  
Kamalnayan Chauhan ◽  
Subhajit Panda ◽  
Rajiv Sarin

Abstract Purpose: Dosimetric comparison between volumetric-modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of bilateral breast cancer (BBC). Materials and methods: Ten patients treated on HT were selected retrospectively. Dose prescription was 50 Gy in 25 fractions to breast/chest wall and supraclavicular fossa (SCF) while tumour bed was simultaneously boosted to 61 Gy in 25 fractions. VMAT plans were made with four mono-isocentric partial arcs. The monitoring unit (MU) and treatment time were used to quantify the treatment efficiency. Target volumes were compared for homogeneity index (HI), conformity index (CI) while organs at risk (OARs) were compared for relevant dose volumes and integral doses (IDs). Result: For targets, no significant difference is observed between VMAT and HT in CI but VMAT could give better HI. The mean lung dose, V20 and V5 is 10·6 Gy versus 8·4 Gy (p-value 0·03), 12% versus 11·5% (p-value 0·5) and 78·1% versus 43·4% (p-value 0·005), respectively. The mean heart dose, V30 and V5 is 4·9 Gy versus 4·7 Gy (p-value 0·88), 0·5% versus 1·5% (p-value 0·18) and 26·2% versus 22·8% (p-value 0·4). Integral dose (ID) for the whole body and heart are comparable: 289 Gy kg versus 299 Gy kg (p-value 0·24) and 2·9 Gy kg versus 2·8 Gy kg (p-value 0·80). ID for lungs was significantly higher with VMAT: 7·9 Gy kg versus 6·3 Gy kg (p-value 0·03). There is a 53% reduction in treatment time and 78% in MU with VMAT against HT. Conclusion: VMAT can generate clinically acceptable plans comparable to HT for BBC. HT shows better control over low dose spillage in lungs compared to VMAT thereby increasing ID to lungs. VMAT shows better homogeneity and efficient treatment delivery than HT.


2021 ◽  
Author(s):  
Xiaoyong Xiang ◽  
Zhen Ding ◽  
Kailian Kang ◽  
Zhitao Dai ◽  
Wenjue Zhang ◽  
...  

Abstract To explore the feasibility of using Volumetric-Modulated Arc Therapy (VMAT) to protect left anterior descending branch (LAD) after breast-conserving surgery for left breast cancer. 15 left breast cancer patients after breast-conserving surgery were selected. 7F-IMRT and 2A-VMAT treatment plans were designed with Varian Eclipse TPS (13.6version). The prescriptions of PTV and PTV Boost were 43.5Gy and 49.5Gy in 15 fractions. The dosimetric parameters, OARs dose sparing and second cancer risk (SCR) were compared between the two plans using a paired t-test. The VMAT plans obtain better PTV conformity and higher mean dose. VMAT plans show a better dose distribution in high dose areas and better sparing of OARs, including left lung, heart, and LAD. The Dmax and Dmean of LAD decreased significantly in VMAT plans. The SCRs of the contralateral lung and breast significantly increased with a higher mean dose. We recommend that contouring and evaluating the dose of LAD and LAD helping structures in left breast cancer radiotherapy. SCR should be evaluated for younger patients.


2016 ◽  
Vol 8 (8) ◽  
pp. 735 ◽  
Author(s):  
Olivier Lauche ◽  
Youlia M Kirova ◽  
Pascal Fenoglietto ◽  
Emilie Costa ◽  
Claire Lemanski ◽  
...  

2012 ◽  
Vol 53 (1) ◽  
pp. 151-153 ◽  
Author(s):  
Akira SAKUMI ◽  
Kenshiro SHIRAISHI ◽  
Tsuyoshi ONOE ◽  
Kentaro YAMAMOTO ◽  
Akihiro HAGA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document