scholarly journals Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Mutational Pattern in the Fourth Pandemic Phase in Greece

2022 ◽  
Vol 44 (1) ◽  
pp. 329-335
Author(s):  
Panagiotis Halvatsiotis ◽  
Sofia Vassiliu ◽  
Panagiotis Koulouvaris ◽  
Kalliopi Chatzantonaki ◽  
Konstantinos Asonitis ◽  
...  

The aim of this study is to investigate the circulating variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from Athens and from rural areas in Greece during July and August 2021. We also present a rapid review of literature regarding significant SARS-CoV-2 mutations and their impact on public health. A total of 2500 nasopharyngeal swab specimens were collected from suspected COVID-19 cases (definition by WHO 2021b). Viral nucleic acid extraction was implemented using an automatic extractor and the RNA recovered underwent qRT-PCR in order to characterize the specimens as positive or negative for SARS-CoV-2. The positive specimens were then used to identify specific Spike gene mutations and characterize the emerging SARS-CoV-2 variants. For this step, various kits were utilized. From the 2500 clinical specimens, 220 were tested positive for SARS-CoV-2 indicating a prevalence of 8.8% among suspected cases. The RT-PCR Ct (Cycle threshold) Value ranged from 19 to 25 which corresponds to medium to high copy numbers of the virus in the positive samples. From the 220 positive specimens 148 (67.3%) were from Athens and 72 (32.7%) from Greek rural areas. As far as the Spike mutations investigated: N501Y appeared in all the samples, D614G mutation appeared in 212 (96.4%) samples with a prevalence of 87.2% in Athens and 98.6% in the countryside, E484K had a prevalence of 10.8% and 12.5% in Athens and the rural areas, respectively. K417N was found in 18 (12.2%) samples from Athens and four (5.6%) from the countryside, P681H was present in 51 (34.5%) Athenian specimens and 14 (19.4%) specimens from rural areas, HV69-70 was carried in 32.4% and 19.4% of the samples from Athens and the countryside, respectively. P681R had a prevalence of 87.2% in Athens and 98.6% in rural areas, and none of the specimens carried the L452R mutation. 62 (28.2%) samples carried the N501Y, P681H, D614G and HV69-70 mutations simultaneously and the corresponding variant was characterized as the Alpha (UK) variant (B 1.1.7). Only six (2.7%) samples from the center of Athens had the N501Y, E484K, K417N and D614G mutations simultaneously and the virus responsible was characterized as the Beta (South African) variant (B 1.351). Our study explored the SARS-CoV-2 variants using RT-PCR in a representative cohort of samples collected from Greece in July and August 2021. The prevalent mutations identified were N501Y (100%), D614G (96.4%), P681R (90.1%) and the variants identified were the Delta (90.1%), Alpha (28.2%) and Beta (2.7%).

Viruses ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 615
Author(s):  
Allen Wing-Ho Chu ◽  
Cyril Chik-Yan Yip ◽  
Wan-Mui Chan ◽  
Anthony Chin-Ki Ng ◽  
Dream Lok-Sze Chan ◽  
...  

SARS-CoV-2 RT-PCR with pooled specimens has been implemented during the COVID-19 pandemic as a cost- and manpower-saving strategy for large-scale testing. However, there is a paucity of data on the efficiency of different nucleic acid extraction platforms on pooled specimens. This study compared a novel automated high-throughput liquid-based RNA extraction (LRE) platform (PHASIFYTM) with a widely used magnetic bead-based total nucleic acid extraction (MBTE) platform (NucliSENS® easyMAG®). A total of 60 pools of nasopharyngeal swab and 60 pools of posterior oropharyngeal saliva specimens, each consisting of 1 SARS-CoV-2 positive and 9 SARS-CoV-2 negative specimens, were included for the comparison. Real-time RT-PCR targeting the SARS-CoV-2 RdRp/Hel gene was performed, and GAPDH RT-PCR was used to detect RT-PCR inhibitors. No significant differences were observed in the Ct values and overall RT-PCR positive rates between LRE and MBTE platforms (92.5% (111/120] vs 90% (108/120]), but there was a slightly higher positive rate for LRE (88.3% (53/60]) than MBTE (81.7% (49/60]) among pooled saliva. The automated LRE method is comparable to a standard MBTE method for the detection of SAR-CoV-2 in pooled specimens, providing a suitable alternative automated extraction platform. Furthermore, LRE may be better suited for pooled saliva specimens due to more efficient removal of RT-PCR inhibitors.


2021 ◽  
Author(s):  
Marco Fabiani ◽  
Katia Margiotti ◽  
Manuela Sabatino ◽  
Antonella Viola ◽  
Alvaro Mesoraca ◽  
...  

Abstract Background Since 2020, the COVID-19 pandemic spread worldwide causing health, economic, and social distresses. Containment strategy relay on rapid and consistent methodology for molecular detection and characterization. The emerging variants of concern (VOCs) are currently associated with increased infectivity, and immune escape (natural defense mechanisms as well as a vaccine). Several VOCs has been detected and include lineage B.1.1.7 first identified in the UK, linage B.1.351 in South Africa, and lineage P.1 (B.1.1.28.1) in Brazil. Here we validated a rapid and low-cost technique to distinguish B.1.1.7, B.1.351 and P.1 SARS-CoV-2 variants by detecting Spike gene mutations using RT-PCR methodology. Results We recruited 77 positive patients affected by Coronavirus Disease-19 (COVID-19). Specific Real-time reverse transcription-polymerase chain reaction (RT-PCR) was employed targeting single nucleotide polymorphisms (SNPs) to screen Spike protein mutations. All data were validated by next generation sequencing (NGS) methodology and using sequence from a public database.Among 77 COVID-19 positive samples we could discriminate with 100% of concordance all the investigated SARS-CoV-2 variants when comparing with NGS method. Conclusions PCR-based assays for identification of circulating VOCs of SARS-CoV-2 resulted in a rapid method to identify the specific SARS-CoV-2 variants allowing a better survey of the spread of the virus and its transmissibility in the pandemic phase.


2021 ◽  
Vol 9 ◽  
Author(s):  
Daniel F. Escobar ◽  
Pablo Díaz ◽  
Diego Díaz-Dinamarca ◽  
Rodrigo Puentes ◽  
Pedro Alarcón ◽  
...  

In January 2021, the Chilean city of Concepción experienced a second wave of coronavirus 2019 (COVID-19) while in early April 2021, the entire country faced the same situation. This outbreak generated the need to modify and validate a method for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in saliva, thereby expanding the capacity and versatility of testing for COVID-19. This study was conducted in February 2021 in the Chilean city of Concepción during which time, the town was under total quarantine. The study participants were mostly symptomatic (87.4%), not hospitalized, and attended care centers because of their health status rather than being asked by the researchers. People coming to the health center in Concepción to be tested for COVID-19 (via reverse transcriptase polymerase chain reaction [RT-PCR]) from a specimen of nasopharyngeal swab (NPS) were then invited to participate in this study. A total of 131 participants agreed to sign an informed consent and to provide saliva and NPS specimens to validate a method in terms of sensitivity, specificity, and statistical analysis of the cycle threshold (Ct) values from the RT-PCR. Calculations pertaining to the 127 participants who were ultimately included in the analysis showed sensitivity and specificity at 94.34% (95% CI: 84.34–98.82%) and 98.65% (95% CI: 92.70–99.97%), respectively. The saliva specimen showed a performance comparable to NPS as demonstrated by the diagnostic parameters. This RT-PCR method from the saliva specimen is a highly sensitive and specific alternative compared to the reference methodology, which uses the NPS specimen. This modified and validated method is intended for use in the in vitro diagnosis of SARS-CoV-2, which provides health authorities in Chile and local laboratories with a real testing alternative to RT-PCR from NPS.


Author(s):  
Alainna J Jamal ◽  
Mohammad Mozafarihashjin ◽  
Eric Coomes ◽  
Jeff Powis ◽  
Angel X Li ◽  
...  

Abstract We enrolled 91 consecutive inpatients with COVID-19 at 6 hospitals in Toronto, Canada, and tested 1 nasopharyngeal swab/saliva sample pair from each patient using real-time RT-PCR for severe acute respiratory syndrome coronavirus 2. Sensitivity was 89% for nasopharyngeal swabs and 72% for saliva (P = .02). Difference in sensitivity was greatest for sample pairs collected later in illness.


2021 ◽  
pp. 1-2
Author(s):  
Atrikumar P. Patel ◽  
Palak Shah ◽  
Pavan Acharya ◽  
Monila N. Patel

The 2019 novel coronavirus [severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)] was rst documented in December 2019 in Wuhan, China, and spread across the globe resulting in [1]. signicant global morbidity and mortality Diagnosis of COVID-19 is mainly done by nasopharyngeal and oropharyngeal swab RT-PCR (Reverse transcriptase - polymerase chain reaction). Real time RT-PCR is of great interest today for detection of SARS- CoV-2 due to its benets as a specic assay.


2020 ◽  
Vol 37 (10) ◽  
pp. 1055-1060 ◽  
Author(s):  
Ziyi Yang ◽  
Yi Liu

Objective The aim of this study is to summarize currently available evidence on vertical transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Study Design A systematic review was conducted following the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-analysis Statement. Results A total of 22 studies comprising 83 neonates born to mothers diagnosed with coronavirus disease 2019 were included in the present systematic review. Among these neonates, three were confirmed with SARS-CoV-2 infection at 16, 36, and 72 hours after birth, respectively, by nasopharyngeal swab real-time polymerase chain reaction (RT-PCR) tests; another six had elevated virus-specific antibody levels in serum samples collected after birth, but negative RT-PCR test results. However, without positive RT-PCR tests of amniotic fluid, placenta, or cord blood, there is a lack of virologic evidence for intrauterine vertical transmission. Conclusion There is currently no direct evidence to support intrauterine vertical transmission of SARS-CoV-2. Additional RT-PCR tests on amniotic fluid, placenta, and cord blood are needed to ascertain the possibility of intrauterine vertical transmission. For pregnant women infected during their first and second trimesters, further studies focusing on long-term outcomes are needed. Key Points


Author(s):  
Monita R Patel ◽  
Darin Carroll ◽  
Emily Ussery ◽  
Hilary Whitham ◽  
Christopher A Elkins ◽  
...  

Abstract Among 146 nasopharyngeal (NP) and oropharyngeal (OP) swab pairs collected ≤7 days after illness onset, Real-Time Reverse Transcriptase Polymerase Chain Reaction assay for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 RT-PCR) diagnostic results were 95.2% concordant. However, NP swab cycle threshold values were lower (indicating more virus) in 66.7% of concordant-positive pairs, suggesting NP swabs may more accurately detect the amount of SARS-CoV-2.


2004 ◽  
Vol 50 (1) ◽  
pp. 67-72 ◽  
Author(s):  
Leo L M Poon ◽  
Kwok Hung Chan ◽  
On Kei Wong ◽  
Timothy K W Cheung ◽  
Iris Ng ◽  
...  

Abstract Background: A novel coronavirus (CoV) was recently identified as the agent for severe acute respiratory syndrome (SARS). We compared the abilities of conventional and real-time reverse transcription-PCR (RT-PCR) assays to detect SARS CoV in clinical specimens. Methods: RNA samples isolated from nasopharyngeal aspirate (NPA; n = 170) and stool (n = 44) were reverse-transcribed and tested by our in-house conventional RT-PCR assay. We selected 98 NPA and 37 stool samples collected at different times after the onset of disease and tested them in a real-time quantitative RT-PCR specific for the open reading frame (ORF) 1b region of SARS CoV. Detection rates for the conventional and real-time quantitative RT-PCR assays were compared. To investigate the nature of viral RNA molecules in these clinical samples, we determined copy numbers of ORF 1b and nucleocapsid (N) gene sequences of SARS CoV. Results: The quantitative real-time RT-PCR assay was more sensitive than the conventional RT-PCR assay for detecting SARS CoV in samples collected early in the course of the disease. Real-time assays targeted at the ORF 1b region and the N gene revealed that copy numbers of ORF 1b and N gene sequences in clinical samples were similar. Conclusions: NPA and stool samples can be used for early diagnosis of SARS. The real-time quantitative RT-PCR assay for SARS CoV is potentially useful for early detection of SARS CoV. Our results suggest that genomic RNA is the predominant viral RNA species in clinical samples.


2021 ◽  
Author(s):  
Jeremy A Garson ◽  
Samuel Badru ◽  
Eleanor L Parker ◽  
Richard S Tedder ◽  
Myra O McClure

The highly transmissible Delta variant of SARS-CoV-2 (B.1.617.2), first identified in India, is currently replacing pre-existing variants in Europe, the USA, and many other parts of the world. It is essential to monitor efficiently its spread to help guide public health policies. Genome sequencing is the gold standard for identification of Delta, but is time-consuming, expensive, and unavailable in many regions. We describe here a rapid and relatively inexpensive alternative to sequencing for specific identification of the Delta variant, by application of double-mismatch allele-specific RT-PCR (DMAS-RT-PCR). The technique exploits forward and reverse allele-specific primers, targeting two spike gene mutations, L452R and T478K, within the same amplicon. The discriminatory power of each primer is enhanced by the presence of an additional mismatch located at the fourth nucleotide from the 3' end. Amplicons are detected in real-time by means of a conventional fluorescently-labelled hydrolysis probe. Specificity was assessed by testing a range of well characterised cell culture-derived viral isolates and clinical samples, most of which had previously been fully sequenced. In all cases the results of viral genotyping by DMAS-RT-PCR were entirely concordant with the results of sequencing, and the assay was shown to discriminate reliably between the Delta variant and other variants of concern (Alpha, B.1.1.7 and Beta, B.1.351), and 'wild-type' SARS-CoV-2. Other respiratory viruses, including influenza A and respiratory syncytial virus, were non-reactive in the assay. The sensitivity of DMAS-RT-PCR matched that of the diagnostic SARS-CoV-2 RT-qPCR screening assay, which targets the E gene. Several samples that could not be sequenced due to insufficient virus could successfully be genotyped by DMAS-RT-PCR. The method we describe would be simple to establish in any laboratory that has the ability to conduct PCR assays and should greatly facilitate monitoring of the spread of the Delta variant throughout the world, and its proportional representation in any SARS-CoV-2-infected population.


2020 ◽  
pp. 131-145
Author(s):  
Ali Hattem Hussain

This meta-analysis study analyzed the data of 47 recent studies with data related SARS-COV-2 viral load detection in different human specimens. 1099 patients were tested for SARS-COV-2 viral load using up to 19 different respiratory and non-respiratory specimens using RT-PCR by targeting different types of viral genes of which ORF1ab is the most commonly used target gene. 9909 specimens were taken from the patients. The mean of viral load cycle threshold value is 17.8 (±11.7), with a median of 15.95 with minimum value of 0.2 and a maximum value of 36.5. Nasopharyngeal swab has the highest positivity rate (90.5%) for viral load detection followed by Bronchoalveolar lavage, nasal swab, nasopharyngeal aspirate, throat swab and sputum. For the non-respiratory specimen, stool and rectal swab are most appropriate specimens followed by blood. The urine is not appropriate specimen for viral load detection due to very low sensitivity. The sputum was positive up to 23 days in a daily manner since start of symptoms except for the days 19, 21, and 23 that were negative for the virus. Three specimens, the nasopharyngeal swab, throat swab, and rectal swab, showed positive RT-PCR results before the appearance of COVID-19 clinical features.  Possible positive results can be present up to 43 days in throat swab, stool, and rectal swab. After negative conversion of respiratory specimens, the viral shedding can continue more than one month from stool and rectal swab. The 3rd day since onset of symptoms is the most day of testing (223/2935). The highest positivity of SARS-COV-2 viral load was recorded in day 16 since the onset of symptoms.              