scholarly journals Energy-Saving Potential of Thermal Diode Tank Assisted Refrigeration and Air-Conditioning Systems

Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 206
Author(s):  
Mingzhen Wang ◽  
Eric Hu ◽  
Lei Chen

Lowering the condensing temperature of the Refrigeration and Air-conditioning (RAC) system has been proven to effectively increase the system’s Coefficient of Performance (COP). This paper revolves around evaluating the energy-saving generated by applying a Thermal Diode Tank (TDT) in the RAC systems. The TDT is a novel invention, which is an insulated water tank equipped with gravity heat pipes. If the TDT was placed outdoors overnight, its inside water would theoretically be at the minimum ambient temperature of the previous night. When the TDT water is used to cool the condenser of RAC systems that operate during the daytime, a higher COP of this TDT assisted RAC (TDT-RAC) system could be achieved compared with the baseline system. In this study, a steady-state performance simulation model for TDT-RAC cycles has been developed. The model reveals that the COP of the TDT-RAC cycle can be improved by 10~59% over the baseline cycle depending on the compressor types. The TDT-RAC cycle with a variable speed compressor can save more energy than that with a fixed speed compressor. In addition, TDT-RAC cycles can save more energy with a higher day/night ambient temperature difference. There is a threshold tank size for a given TDT-RAC cycle to save energy, and the energy-saving can be improved by enlarging the tank size. A desk-top case study based on real weather data for Adelaide in January 2021 shows that 9~40% energy could be saved by TDT-RAC systems every summer day on average.

Solar Energy ◽  
2006 ◽  
Author(s):  
Junjie Liu ◽  
Bin Wang ◽  
Youhao Xu

In order to fulfill the indoor comfort and health requirements, people need to supply a large amount of outdoor fresh air into the indoor environment. In the past, because of the poor airtight performance of the residential buildings in China, there is usually no mechanical ventilator installed, almost all of the outdoor air infiltrates from the leaks through the windows and doors. Recently, in order to improve the energy saving performance, the windows and doors of the residential buildings become more and more airtight so that the outdoor air can’t infiltrate into the rooms easily, but it results in the worse and worse indoor air quality. People need supply enough outdoor fresh air into the rooms without increasing the energy consumption greatly. The installation of the enthalpy recovery ventilator (ERV) is an effective method. It can transfer heat and moisture from the exhaust air into the outdoor fresh air to save energy. Nowadays, ERV has been widely used in the commercial and industry buildings, and started in the residential buildings in China. But ERV is not always energy saving in anywhere and anytime. Its energy saving performance depends on a lot of factors, such as the outdoor environmental condition, the enthalpy effectiveness of the enthalpy recovery medium, the Coefficient of Performance (COP) of the air condition system and so on. Based on the weather data, this paper calculates the hourly energy saving performance of ERV for residential buildings that are hypothetically located in five Chinese representative cities of five different climate zones in summer. It gives the definition of the cooling ventilation season and studies the influence factors related to the energy saving performance of ERV.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 81
Author(s):  
Rongjiang Ma ◽  
Shen Yang ◽  
Xianlin Wang ◽  
Xi-Cheng Wang ◽  
Ming Shan ◽  
...  

Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems.


2010 ◽  
Vol 31 (2) ◽  
pp. 77-94 ◽  
Author(s):  
Agnieszka Kuczyńska ◽  
Władysław Szaflik

Absorption and adsorption chillers applied to air conditioning systemsThis work presents an application possibility of sorption refrigerators driven by low temperature fluid for air conditioning of buildings. Thermodynamic models were formulated and absorption LiBr-water chiller with 10 kW cooling power as well as adsorption chiller with silica gel bed were investigated. Both of them are using water for desorption process with temperatureTdes= 80 °C. Coefficient of performance (COP) for both cooling cycles was analyzed in the same conditions of the driving heat source, cooling waterTc= 25 °C and temperature in evaporatorTevap= 5 °C. In this study, the computer software EES was used to investigate the performance of absorption heat pump system and its behaviour in configuration with geothermal heat source.


Author(s):  
Ali Al-Alili ◽  
Yunho Hwang ◽  
Reinhard Radermacher

In hot and humid regions, removal of moisture from the air represents a considerable portion of the air conditioning load. Conventionally, air conditioning systems have to lower the air temperature below its dew point to accomplish dehumidification. Desiccant air conditioners offer a solution to meet the humidity and temperature requirements of buildings via decoupling latent and sensible loads. In this work, the performance of a new desiccant material is investigated experimentally. This desiccant material can be regenerated using a low temperature heat source, as low as 45°C. It also has a unique S-shape isotherm. The effects of the process air stream’s temperature and humidity, the regeneration temperature, the ventilation mass flow rate, and the desiccant wheel’s rotational speed on the cycle performance are investigated. ARI-humid conditions are used as a baseline and the moisture mass balance is maintained within 5%. The results are presented in terms of the moisture removal rate and latent coefficient of performance (COPlat). The results show a desiccant wheel’s COPlat higher than unity when it is coupled with an enthalpy wheel.


Author(s):  
Jéssica Duarte ◽  
Lara Werncke Vieira ◽  
Rafael Zanardo ◽  
Augusto Delavald Marques ◽  
Paulo Smith Schneider

2020 ◽  
Vol 10 (4) ◽  
pp. 1513 ◽  
Author(s):  
Daniel Sánchez-García ◽  
David Bienvenido-Huertas ◽  
Jesús A. Pulido-Arcas ◽  
Carlos Rubio-Bellido

Reports of Intergovernmental Panel on Climate Change have set various greenhouse gas emissions scenarios, through which the evolution of the temperature of the planet can be estimated throughout the 21st century. The reduction of the emissions from the different activities carried out by mankind is crucial to mitigate greenhouse gas emissions. One of the most significant activities is users’ behaviour within buildings, particularly the use of Heating, Ventilation and Air-Conditioning systems. Modifying users’ behaviour patterns to guarantee acceptable thermal conditions inside buildings could lead to considerable energy saving percentages, and adaptive thermal comfort models could be an opportunity to achieve important savings. For this reason, this study analyzes the potential to apply adaptive thermal comfort models to use artificial air-conditioning systems by modifying setpoint temperatures. The analysis was conducted in five major European cities (Barcelona, Berlin, Bern, Rome, and Vienna) and in five climate change scenarios in the year 2050. The results showed that, in general, the energy saving achieved by adaptive strategies was larger in the cities with a greater cooling demand. Also, in both Representative Concentration Pathways (RCP) of the Fifth Assessment Report (AR5) considered, the energy saving were decreased in the cities of Barcelona and Rome, with values lower than those of the Fourth Assessment Report (AR4) scenarios considered, whereas in the cities of Berlin, Bern, and Vienna, the saving in the RCP scenarios is greater than those in the other scenarios.


Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3470 ◽  
Author(s):  
Win-Jet Luo ◽  
Dini Faridah ◽  
Fikri Rahmat Fasya ◽  
Yu-Sheng Chen ◽  
Fikri Hizbul Mulki ◽  
...  

A hybrid solid desiccant cooling system (SDCS), which combines a solid desiccant system and a vapor compression system, is considered to be an excellent alternative for commercial and residential air conditioning systems. In this study, a solar-assisted hybrid SDCS system was developed in which solar-heated water is used as an additional heat source for the regeneration process, in addition to recovering heat from the condenser of an integrated heat pump. A solar thermal collector sub-system is used to generate solar regeneration water. Experiments were conducted in the typically hot and humid weather of Taichung, Taiwan, from the spring to fall seasons. The experimental results show that the overall performance of the system in terms of power consumption can be enhanced by approximately 10% by integrating a solar-heated water heat exchanger in comparison to the hybrid SDCS system. The results show that the system performs better when the outdoor humidity ratio is large. In addition, regarding the effect of ambient temperature on the coefficient of performance (COP) of the systems, a critical value of outdoor temperature exists. The COP of the systems gradually rises with the increase in ambient temperature. However, when the ambient temperature is greater than the critical value, the COP gradually decreases with the increase in ambient temperature. The critical outdoor temperature of the hybrid SDCS is from 26 °C to 27 °C, and the critical temperature of the solar-assisted hybrid SDCS is from 27 °C to 30 °C.


2014 ◽  
Vol 137 (1) ◽  
Author(s):  
M. Alkhair ◽  
M. Y. Sulaiman ◽  
K. Sopian ◽  
C. H. Lim ◽  
E. Salleh ◽  
...  

The modeling of the performance of a one refrigeration ton (RT) solar assisted adsorption air-conditioning refrigeration system using activated carbon fiber/ethanol as the adsorbent/adsorbate pair has been undertaken in this study. The effects of hot water, cooling water, chilled water inlet temperatures, and hot water and chilled water flow rates were taken into consideration in the optimization of the system and in the design of the condenser, evaporator, and hot water storage tank. The study includes analysis of the weather data and its effect on both the adsorption system and the cooling load. This is then followed by estimation of the cooling capacity and coefficient of performance (COP) of the adsorption system as a function of the input parameters. The results of the model will be compared to experimental data in a next step.