scholarly journals Seismic Response Mitigation of a Television Transmission Tower by Shape Memory Alloy Dampers

Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6987
Author(s):  
Jingbo Wu ◽  
Bo Chen ◽  
Lunhai Zhi ◽  
Xinxin Song

High-rise television transmission towers are of low damping and may vibrate excessively when subjected to strong earthquakes. Various dynamic absorbers and dampers are proposed to protect television transmission towers from excessive vibrations and damages. Up to now, the seismic damage reduction in television towers, using SMA dampers under seismic excitations, has not been conducted. To this end, the response reduction in a flexible television tower, disturbed by earthquakes using SMA dampers, is conducted in this study. A two-dimensional dynamic model is developed for dynamic computation at first. The mathematical model of an SMA damper is proposed, and the equations of motion of the tower, without and with, are established, respectively. The structural dynamic responses are examined in the time and the frequency domain, respectively. The effects of damper stiffness, service temperature, hysteresis loops, and earthquake intensity on control efficacy are investigated in detail. In addition, the power spectrum density curves, of dynamic responses and the energy responses, are compared to provide deep insights into the developed control approach. The control performance of SMA dampers is compared with that of widely-used friction dampers. The analytical observations indicate that SMA dampers with optimal parameters can substantially reduce the vibrations of TV transmission towers under seismic excitations.

2021 ◽  
pp. 136943322110339
Author(s):  
Jian Guo ◽  
Changliang Xiao ◽  
Jiantao Li

A hill with a lattice transmission tower presents complex wind field characteristics. The commonly used computational fluid dynamics (CFD) simulations are difficult to analyze the wind resistance and dynamic responses of the transmission tower due to structural complexity. In this study, wind tunnel tests and numerical simulations are conducted to analyze the wind field of the hill and the dynamic responses of the transmission tower built on it. The hill models with different slopes are investigated by wind tunnel tests to measure the wind field characteristics, such as mean speed and turbulence intensity. The study shows that the existence of a transmission tower reduces the wind speed on the leeward slope significantly but has little effect on the windward slope. To study the dynamic behavior of the transmission tower, a hybrid analysis procedure is used by introducing the measured experimental wind information to the finite element tower model established using ANSYS. The effects of hill slope on the maximum displacement response of the tower are studied. The results show that the maximum value of the response is the largest when the hill slope is 25° compared to those when hill slope is 15° and 35°. The results extend the knowledge concerning wind tunnel tests on hills of different terrain and provide a comprehensive understanding of the interactive effects between the hill and existing transmission tower regarding to the wind field characteristics and structural dynamic responses.


Author(s):  
Hong-Nan Li ◽  
Wen-Long Shi ◽  
Guo-Xin Wang

The simplified computational models of high-voltage transmission tower-line system under out-of-plane and in-plane vibrations are presented due to seismic excitations in this paper. The equations of motion are derived and the computer program is compiled to obtain the earthquake responses of the coupled system. To verify the rationality of the proposed approaches, the shaking-table experiments of the coupled system of transmission lines and their supporting towers are carried out and the results indicate that the errors of theoretical and testing results of systemic seismic responses are within the acceptable arrange in engineering area. Based on these studies, a simplified analysis method is proposed to make the seismic response calculation of coupled tower-conductor system faster and more effective.


2014 ◽  
Vol 580-583 ◽  
pp. 1595-1599 ◽  
Author(s):  
Xue Liang Wang ◽  
Liang Jin

This research investigated the influence of mortise-tenon joint before and after damage on seismic performance of ancient lifted-beam timber structure. Dynamic responses of an ancient timber structure under various earthquake intensities were analyzed by ANSYS to extract the M-θ hysteresis loops of mortise-tenon joints before and after damage. The area of the largest hysteresis loop was taken as quantitative indicator to measure energy dissipation of mortise-tenon joints. The results shows that if some mortise-tenon joints were damaged, they dissipated much less earthquake energy decreasing by 31.8%-38.5%, and top displacement of structures increased by 1.79%-5.96% correspondingly. Moreover, the displacement under 8-degree-fortification, 7-degree-rare earthquake intensity increased most obviously. Therefore, energy dissipation of mortise-tenon joint is a main indicator to the assessment of seismic performance of a damaged ancient timber structure.


Author(s):  
Kuan Ye ◽  
Kai Zhou ◽  
Ren Zhigang ◽  
Ruizhe Zhang ◽  
Chunsheng Li ◽  
...  

The power transmission tower’s ground electrode defect will affect its normal current dispersion function and threaten the power system’s safe and stable operation and even personal safety. Aiming at the problem that the buried grounding grid is difficult to be detected, this paper proposes a method for identifying the ground electrode defects of transmission towers based on single-side multi-point excited ultrasonic guided waves. The geometric model, ultrasonic excitation model, and physical model are established, and the feasibility of ultrasonic guided wave detection is verified through the simulation and experiment. In actual inspection, it is equally important to determine the specific location of the defect. Therefore, a multi-point excitation method is proposed to determine the defect’s actual position by combining the ultrasonic guided wave signals at different excitation positions. Besides, the precise quantification of flat steel grounding electrode defects is achieved through the feature extraction-neural network method. Field test results show that, compared with the commercial double-sided excitation transducer, the single-sided excitation transducer proposed in this paper has a lower defect quantization error in defect quantification. The average quantization error is reduced by approximately 76%.


Author(s):  
Wenhua Wang ◽  
Zhen Gao ◽  
Xin Li ◽  
Torgeir Moan ◽  
Bin Wang

In the last decade the wind energy industry has developed rapidly in China, especially offshore. For a water depth less than 20m, monopile and multi-pile substructures (tripod, pentapod) are applied widely in offshore wind farms. Some wind farms in China are located in high seismicity regions, thus, the earthquake load may become the dominant load for offshore wind turbines. This paper deals with the seismic behavior of an offshore wind turbine (OWT) consisting of the NREL 5MW baseline wind turbine, a pentapod substructure and a pile foundation of a real offshore wind turbine in China. A test model of the OWT is designed based on the hydro-elastic similarity. Test cases of different load combinations are performed with the environmental conditions generated by the Joint Earthquake, Wave and Current Simulation System and the Simple Wind Field Generation System at Dalian University of Technology, China, in order to investigate the structural dynamic responses under different load conditions. In the tests, a circular disk is used to model the rotor-nacelle system, and a force gauge is fixed at the center of the disk to measure the wind forces during the tests. A series of accelerometers are arranged along the model tower and the pentapod piles, and strain gauges glued on the substructure members are intended to measure the structural dynamic responses. A finite element model of the complete wind turbine is also established in order to compare the theoretical results with the test data. The hydro-elastic similarity is validated based on the comparison of the measured dynamic characteristics and the results of the prototype modal analysis. The numerical results agree well with the experimental data. Based on the comparisons of the results, the effect of the wind and sea loads on the structural responses subjected to seismic is demonstrated, especially the influence on the global response of the structure. It is seen that the effect of the combined seismic, wind, wave and current load conditions can not be simply superimposed. Hence the interaction effect in the seismic analysis should be considered when the wind, wave and current loads have a non-negligible effect.


1988 ◽  
Vol 9 (3) ◽  
pp. 241-251
Author(s):  
Zhang Yi-song ◽  
Xu Yin-ge ◽  
Gao Dc-ping

2021 ◽  
Vol 9 ◽  
Author(s):  
Jiaxiang Li ◽  
Biao Wang ◽  
Jian Sun ◽  
Shuhong Wang ◽  
Xiaohong Zhang ◽  
...  

Ice shedding causes transmission lines to vibrate violently, which induces a sharp increase in the longitudinal unbalanced tension of the lines, even resulting in the progressive collapse of transmission towers in serious cases, which is a common ice-based disaster for transmission tower-line systems. Based on the actual engineering characteristics of a 500 kV transmission line taken as the research object, a finite element model of a two-tower, three-line system is established by commercial ANSYS finite element software. In the modeling process, the uniform mode method is used to introduce the initial defects, and the collapse caused by ice shedding and its influencing parameters are systematically studied. The results show that the higher the ice-shedding height is, the greater the threat of ice shedding to the system; furthermore, the greater the span is, the shorter the insulator length and the greater the dynamic response of the line; the impact of ice shedding should be considered in the design of transmission towers.


2020 ◽  
Vol 4 (2) ◽  
pp. 1-7
Author(s):  
Fatai Hammed ◽  
M. A. Usman ◽  
S. A. Onitilo ◽  
F. A. Alade ◽  
K. A. Omoteso

In this study, the response of two homogeneous parallel beams with two-parameter Pasternak elastic foundation subjected to a constant uniform partially distributed moving force is considered. On the basis of Euler-Bernoulli beam theory, the fourth order partial differential equations of motion describing the behavior of the beams when subjected to a moving force were formulated. In order to solve the resulting initial-boundary value problem, finite Fourier sine integral technique and differential transform scheme were employed to obtain the analytical solution. The dynamic responses of the two beams obtained was investigated under moving force conditions using MATLAB. The effects of speed of the moving force, layer parameters such as stiffness (K_0) and shear modulus (G_0 ) have been conducted for the moving force. Various values of speed of the moving load, stiffness parameters and shear modulus were considered. The results obtained indicates that response amplitudes of both the upper and lower beams increases with increase in the speed of the moving load. Increasing the stiffness parameter is observed to cause a decrease in the response amplitudes of the beams. The response amplitudes decreases with increase in the shear modulus of the linear elastic layer.


Sign in / Sign up

Export Citation Format

Share Document