scholarly journals A Stability-Indicating Ultra Performance Liquid Chromato-graphic (UPLC) Method for the Determination of a Mycophenolic Acid-Curcumin Conjugate and Its Applications to Chemical Kinetic Studies

Molecules ◽  
2021 ◽  
Vol 26 (17) ◽  
pp. 5398
Author(s):  
Yonelian Yuyun ◽  
Ponsiree Jithavech ◽  
Worathat Thitikornpong ◽  
Opa Vajragupta ◽  
Pornchai Rojsitthisak

A simple, precise, and accurate reversed-phase ultra-performance liquid chromatographic (UPLC) method was developed and validated for the determination of a mycophenolic acid-curcumin (MPA-CUR) conjugate in buffer solutions. Chromatographic separation was performed on a C18 column (2.1 × 50 mm id, 1.7 µm) with a gradient elution system of water and acetonitrile, each containing 0.1% formic acid, at a flow rate of 0.6 mL/min. The column temperature was controlled at 33 °C. The compounds were detected simultaneously at the maximum wavelengths of mycophenolic acid (MPA), 254 nm, and curcumin (CUR), or MPA-CUR, at 420 nm. The developed method was validated according to the ICH Q2(R1) guidelines. The linear calibration curves of the assay ranged from 0.10 to 25 μg/mL (r2 ≥ 0.995, 1/x2 weighting factor), with a limit of detection and a limit of quantitation of 0.04 and 0.10 μg/mL, respectively. The accuracy and precision of the developed method were 98.4–101.6%, with %CV < 2.53%. The main impurities from the specificity test were found to be MPA and CUR. Other validation parameters, including robustness and solution stability, were acceptable under the validation criteria. Forced degradation studies were conducted under hydrolytic (acidic and alkaline), oxidative, thermal, and photolytic stress conditions. MPA-CUR was well separated from MPA, CUR, and other unknown degradation products. The validated method was successfully applied in chemical kinetic studies of MPA-CUR in different buffer solutions.

Author(s):  
PRASANTHI CHENGALVA ◽  
MADHAVI KUCHANA

Objective: The objective of the present study is to develop simple, rapid, sensitive, accurate and economic stability-indicating ultra-performance liquid chromatographic (UPLC) method for the simultaneous quantification of phenylephrine hydrochloride, chlorpheniramine maleate, paracetamol, guaiphenesin and bromhexine hydrochloride in bulk and tablet dosage form. Methods: The separation of drugs in the chromatographic column was accomplished on Hibar C18 (100 mm x 2.1 mm, 1.6 µm) column at a detection wavelength of 220 nm. The mobile phase was a combination of sodium phosphate monobasic monohydrate buffer (pH was adjusted to 3.5 with orthophosphoric acid) and acetonitrile in the ratio of 70:30 % v/v which was pumped at a flow rate of 0.3 ml/min. The column temperature was maintained at 30 °C and the injection volume was 0.3 µl. Forced degradation studies of drugs were carried out using acid, base, peroxide, light and heat. Results: All the five drugs have been eluted within 3 min. The retention times were found to be 0.834 min, 1.199 min, 1.600 min, 1.979 min and 2.525 min for phenylephrine, chlorpheniramine maleate, paracetamol, guaiphenesin and bromhexine respectively. The correlation coefficient (r2) was found to be 0.999 for all the drugs. The recovery levels were found to be in the range of 99.17 % to 100.69 %. RSD values of drugs were found to be below 2 %. The results of limit of detection and quantitation specified the sensitivity of the developed method. Significant degradation of drugs as a result of stress studies was found in acid, base and peroxide, but they were slightly degraded in photolytic and thermal conditions. The method has effectively resolved the degraded products. All the validation parameters were found to be within the limits according to International Conference on Harmonization (ICH) guidelines. Conclusion: A simple and rapid UPLC method was established for the determination of five drugs. Hence, the proposed method can be employed for the quality control of specified drugs in bulk and pharmaceutical formulation even in the presence of degradation products.


2021 ◽  
Vol 33 (11) ◽  
pp. 2737-2745
Author(s):  
Md Irshad Alam ◽  
Aquil-Ur-Rahim Siddiqui

An innovative, specific, economical and precise method was developed and validated by employing reverse phase high performance liquid chromatography (HPLC) for contemporaneous estimation of dextromethorphan hydrobromide (DHB) along with its impurities in liquid formulation with forced degradation studies and confirmation of content of DHB in composition label in three market formulations along with their impurities were detected by this method. The optimized chromatographic conditions comprised of column (25 cm × 0.46 cm) × 5 μm Kromasil C8 bearing flow rate of 1.5 mL/min and wavelength 220 nm for UV-estimation. Design of experiments were implemented by following Box Behnken design with most optimum parameters selected as follows, column temperature (A), flow rate (B) and pH (C) with corresponding responses comprised of resolution between related compound A (RCA) and DHB (Y1), tailing of DHB (Y2) and resolution between related compound B (RCB) and DHB (Y3). Stress testing was performed and proved that method was stable as no interfering peaks were observed. All validation parameters including suitability, linearity, accuracy, specificity, limit of detection, limit of quantitation, ruggedness, robustness and stress study were evaluated as per updated ICH guidelines and found to be within limit for pure DHB and detected impurities.


Author(s):  
Sandip A Telavane ◽  
Seema Kothari ◽  
Manohar V. Lokhande

Validation is important technique for detection, progress and estimation of drugs for pharmaceutical analysis. Aim of this article was to check the progress and validation of the method employed for the Residual Solvents in Bisoprolol Fumarate by Gas Chromatographic technique. The objective of this protocol is to validate a GC method of analysis for detection and Quantification of Residual Solvents Methanol, Acetone and Methylene dichloride in Bisoprolol Fumarate. In the pharmaceutical industry, validation policy is more important for documented of validation, types of validation and validation policy. The method was developed accurately and validation parameters are explained. Chromatographic condition was GC- 2014, gas chromatograph equipped with FID detector, column: 30 m x 0.32 mm ID x 1.8 µm DB - 624 capillary column or equivalent and column temperature was 45°C (hold 7 minutes) to 250°C @ 40°C/minutes, hold at 250°C for 3 minutes. The parameters such as Accuracy, Specificity, Precision, Linearity and Range, Limit of detection (LOD), Limit of quantitation (LOQ), ruggedness, robustness and system suitability testing with residual solvent such as Methanol, Acetone and methylene dichloride. All validation parameters are used in the routine and stability analysis.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (05) ◽  
pp. 56-64
Author(s):  
Rani A Prameela ◽  
S. Madhavi ◽  
Rao B. Tirumaleswara ◽  
Sudheer Reddy CH.

A novel Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the simultaneous determination of antidiabetic drugs metformin hydrochloride and nateglinide. The method was developed using a Waters ACQUITY UPLC SB C18 (100 × 2.1 mm, 1.8 μm) column. The mobile phase consisting of 0.01 % potassium dihydrogen phosphate buffer (pH 5.8): acetonitrile (50: 50 V/V) was used throughout the analysis. The flow rate was 0.3 mL/min, the injection volume was 1.0 μL, column temperature was 30 0C, run time 3 min and detection was carried at 238 nm using a TUV detector. The retention times of metformin hydrochloride and nateglinide were found to be 1.28 1.71 min, respectively. Metformin hydrochloride and nateglinide were found to be linear over the concentration range of 125-750 and 15-90 μg/mL. The limit of detection and the limit of quantification for metformin hydrochloride were found to be 0.22 and 0.68 μg/mL, respectively, and, for nateglinide, 0.02 and 0.6 μg/mL, respectively. Developed method was validated as per ICH guidelines. The specificity of the method was confirmed by forced degradation study. The suggested method is suitable for determination of metformin hydrochloride and nateglinide in bulk and pharmaceutical dosage forms.


Author(s):  
Birva A. Athavia ◽  
Zarna R. Dedania ◽  
Ronak R. Dedania ◽  
S. M. Vijayendra Swamy ◽  
Chetana B. Prajapati

Objective: The aim and objective of this study was to develop and validate Stability Indicating HPLC method for determination of Vilazodone Hydrochloride.Methods: The method was carried out on a Phenomenex, C18 (250x4.6 mm, 5 µm) Column using a mixture of Acetonitrile: Water (50:50v/v), pH adjusted to 3.3 with Glacial Acetic Acid for separation. The flow rate was adjusted at 1 ml/min and Detection was carried out at 240 nm.Results: The retention time of vilazodone hydrochloride was found to be 2.3 min. The calibration curve was found to be linear in the range 25-75µg/ml with a correlation coefficient (R2=0.996). The limit of detection and limit of quantitation were found to be 4.78µg/ml and 14.48µg/ml respectively. The % recovery of vilazodone hydrochloride was found to be in the range of 98.21±0.08 % to 99.07±0.64%. The proposed method was successfully applied for the estimation of vilazodone hydrochloride in marketed tablet formulation.Vilazodone Hydrochloride was subjected to forced degradation under Acidic, Alkaline, Oxidation, Dry Heat and Photolytic degradation conditions. Vilazodone hydrochloride showed 3.12% degradation under acidic condition, 4.78% under alkaline condition, 7.8% under oxidation condition, 3.53% under dry heat condition and 4.9% under photolytic condition.Acid degradation impurity was identified and characterised by LC-MS/MS was found to be 1-(4-Penten-1-yl) piperazine having molecular weight 154.253 (m/z 155.08) and Molecular Formula C9H18N2.Conclusion: A simple, precise, rapid and accurate Stability Indicating HPLC method has been developed and validated for the determination of Vilazodone Hydrochloride in presence of its degradation products as per the ICH Guidelines. 


2019 ◽  
Vol 9 (4-A) ◽  
pp. 349-354
Author(s):  
BALU KHANDARE ◽  
Atish C. Musle ◽  
Sanket S. Arole ◽  
Pravin V. Popalghat

Abstract: A simple, precise and economical UV-spectrophotometric method has been developed for the estimation of Olmutinib from bulk. Two methods were developed First method (A) applied was area under curve (AUC) in which the area was integrated in wavelength from 262-272nm. Second method (B) was first order derivative spectrometric method. In this method absorbance at λmin=256.57nm, λmax=282.83nm and zero cross=267.68nm was measured. Calibration curves were plotted for the method by using instrumental response at selected wavelength and concentration of analyte in the solution. In both the methods, linearity was observed in the concentration range of 2-12µg/ml at the λmax=267.68nm. Accuracy and precision studies were carried out and results were satisfactorily obtained. The drug at each of the 80 %, 100 % and 120 % levels showed good recoveries that is in the range of 98.00 to 99.00% for both methods, hence it could be said that the method was accurate. Limit of detection (LOD) and limit of quantitation (LOQ) were determined for the method. The method was validated as per International Conference on Harmonization. All validation parameters were within the acceptable limit. The developed method was successfully applied to estimate the amount of Olmutinib in pharmaceutical formulation.


2010 ◽  
Vol 7 (1) ◽  
pp. 246-252 ◽  
Author(s):  
S. K. Patro ◽  
S. K. Kanungo ◽  
V. J. Patro ◽  
N. S. K. Choudhury

A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/mL using 0.01 M NH4H2PO4(pH 3.5) buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 mL/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 31-38
Author(s):  
R. S. Ch Phani ◽  
◽  
K. R. S. Prasad ◽  
R. M Useni

A simple, precise and stability-indicating RP-HPLC method was developed for simultaneous quantification of oxycodone (OXCD) and naltrexone (NTRX) in combined dosage form. The developed method was validated with respect to precision, linearity, accuracy, robustness, ruggedness, sensitivity and solution stability. The method was developed with ammonium di hydrogen phosphate buffer (pH 5.0) and acetonitrile in a ratio of 55:45 (v/v) as mobile phase at a flow rate of 1.0 mL/minute over Intersil ODS C18 column (250 mm × 4.6 mm×5μ).The UV detection wavelength was fixed at 235 nm. The column temperature was maintained at ambient temperature. The method showed good linearity with correlation coefficient values of 0.9990 and 0.9994 for OXCD and NTRX. The percent recoveries of the two drugs found within the limits of 98.0–102.0%. The LOQ concentrations of OXCD and NTRX are 0.625 μg/ mL and 0.075 μg/mL, respectively. The LOD concentrations of OXCD and NTRX are 0.3125 μg/mL and 0.0375 μg/mL, respectively. According to ICH guidelines forced degradation study was validated.


2007 ◽  
Vol 90 (3) ◽  
pp. 720-724
Author(s):  
Sevgi Tatar Ulu

Abstract A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-Cl). A mobile phase consisting of acetonitrile10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were &lt;0.46 and &lt;0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Roghaieh Khoshkam ◽  
Minoo Afshar

A rapid and stability-indicating RP-HPLC method was developed for determination of l-carnitine in tablets. The separation was based on a C18 analytical column using a mobile phase which consisted of 0.05 M phosphate buffer (pH = 3): ethanol (99 : 1), including 0.56 mg/mL of sodium 1-heptanesulfonate. Column temperature was set at 50°C and quantitation was achieved by UV detection at 225 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. Among the different stress conditions, the exposure to acidic and basic conditions was found to be an important adverse stability factor. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in l-carnitine concentration range of 84.74–3389.50 µg/mL (r2=0.9997). Precision was evaluated by replicate analysis in which relative standard deviation (RSD) values for areas were found below 2.0%. The recoveries obtained (100.83%–101.54%) ensured the accuracy of the developed method. The expanded uncertainty (3.14%) of the method was also estimated from method validation data. Accordingly, the proposed validated and rapid procedure was proved to be suitable for routine analyzing and stability studies of l-carnitine in tablets.


Sign in / Sign up

Export Citation Format

Share Document