scholarly journals Development and Validation of an Analytical HPLC Method to Assess Chemical and Radiochemical Purity of [68Ga]Ga-NODAGA-Exendin-4 Produced by a Fully Automated Method

Molecules ◽  
2022 ◽  
Vol 27 (2) ◽  
pp. 543
Author(s):  
Silvia Migliari ◽  
Antonino Sammartano ◽  
Marti Boss ◽  
Martin Gotthardt ◽  
Maura Scarlattei ◽  
...  

Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in β-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R–avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 μg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5–0.75 μg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) <2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% <2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 μg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.

2021 ◽  
Vol 14 (3) ◽  
pp. 188
Author(s):  
Ines Katzschmann ◽  
Heike Marx ◽  
Klaus Kopka ◽  
Ute Hennrich

For the PET imaging of prostate cancer, radiotracers targeting the prostate-specific membrane antigen (PSMA) are nowadays used in clinical practice. [18F]PSMA-1007, a radiopharmaceutical labeled with fluorine-18, has excellent properties for the detection of prostate cancer. Essential for the human use of a radiotracer is its production and quality control under GMP-compliance. For this purpose, all analytical methods have to be validated. [18F]PSMA-1007 is easily radiosynthesized in a one-step procedure and isolated using solid phase extraction (SPE) cartridges followed by formulation of a buffered injection solution and for the determination of its chemical and radiochemical purity a robust, fast and reliable quality control method using radio-HPLC is necessary. After development and optimizations overcoming problems in reproducibility, the here described radio-HPLC method fulfills all acceptance criteria—for e.g., specificity, linearity, and accuracy—and is therefore well suited for the routine quality control of [18F]PSMA-1007 before release of the radiopharmaceutical. Recently a European Pharmacopeia monograph for [18F]PSMA-1007 was published suggesting a different radio-HPLC method for the determination of its chemical and radiochemical purity. Since the here described method has certain advantages, not least of all easier technical implementation, it can be an attractive alternative to the monograph method. The here described method was successfully validated on several radio-HPLC systems in our lab and used for the analysis of more than 60 batches of [18F]PSMA-1007. Using this method, the chemical and radiochemical purity of [18F]PSMA-1007 can routinely be evaluated assuring patient safety.


2020 ◽  
Vol 13 ◽  
Author(s):  
Silvia Migliari ◽  
Antonino Sammartano ◽  
Maura Scarlattei ◽  
Giorgio Baldari ◽  
Claudia Silva ◽  
...  

Background: Due to its overexpression in a variety of tumor types, the chemokine receptor 4 (CXCR4) represents a highly relevant diagnostic and therapeutic target in nuclear oncology. Recently, [68Ga]Ga-DOTA-Pentixafor has emerged as an excellent imaging agent for positron emission tomography (PET) of CXCR4 expression in vivo. Preparation conditions may influence the quality and in vivo behaviour of this tracer and no standard procedure for the quality controls (QCs) is available. Objective: The developed analytical test method was validated because a specific monograph in the Pharmacopoeia is not available for [68Ga]Ga-DOTA-Pentixafor. Method: A stepwise approach was used, based on the quality by design (QbD) concept of the ICH Q2 (R1) and Q8 (Pharmaceutical Development) guidelines in accordance with the regulations and requirements of EANM, SNM, IAEA and WHO. Results: The purity and quality of the radiopharmaceutical obtained according to the proposed method resulted high enough to safely administrate it to patients. Excellent linearity was found between 0.5 and 4 μg/mL, with a correlation coefficient (r2 ) for calibration curves equal to 0.999, average coefficient of variation (CV%) < 2% and average bias% that doesn't deviate more than 5% for all concentrations. Conclusion: This study developed a new rapid and simple HPLC method of analysis for the routine QCs of [68Ga]GaDOTA-Pentixafor to guarantee the high quality of the finished product before release.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Małgorzata Kowalska ◽  
Magdalena Woźniak ◽  
Michał Kijek ◽  
Paulina Mitrosz ◽  
Jerzy Szakiel ◽  
...  

AbstractThe work mainly focused on a validation of the method for determining the content of salicylic acid and individual unknown impurities in new pharmaceutical product—tablets containing: 75, 100 or 150 mg of acetylsalicylic acid and glycine in the amount of 40 mg for each dosage. The separation of the components was carried out by means of HPLC, using a Waters Symmetry C18 column (4.6 × 250 mm, 5 μm) as the stationary phase. The mobile phase consisted of a mixture of 85% orthophosphoric acid, acetonitrile and purified water (2:400:600 V/V/V). Detection was carried out at a wavelength of 237 nm, with a constant flow rate of 1.0 ml min−1. In order to verify the method, linearity, precision (repeatability and reproducibility), accuracy, specificity, range, robustness, system precision, stability of the test and standard solution, limit of quantification and forced degradation were determined. Validation tests were performed in accordance with ICH (International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use) guidelines. The method was validated successfully. It was confirmed that the method in a tested range of 0.005–0.40% salicylic acid with respect to acetylsalicylic acid content is linear, precise and accurate.


Author(s):  
Miriam del Carmen Carrasco-Portugal ◽  
Francisco Javier Flores-Murrieta

Pharmaceutical alternatives are products with the same active moiety, but different salt, ester or pharmaceutical form. Regulatory agencies have different criteria for this kind of drug. The European Medicines Agency (EMA) accepts the generic substitution using these alternatives, whereas the Food and Drug Administration (FDA) only authorizes generic substitution of pharmaceutical equivalents. The objective of this paper is to describe some relevant aspects that should be considered before deciding on making a generic substitution with pharmaceutical alternatives. It is important to note that a pharmaceutical alternative must show no significant difference in the rate and extent of absorption (bioequivalence) in a well-conducted in vivo study when compared with the reference formulation. Current Mexican regulations state that generic substitution is possible using pharmaceutical alternatives when bioequivalence is demonstrated in in vivo studies conducted under the NOM-177-SSA1-2013 criteria. In conclusion, generic substitution with pharmaceutical alternatives is possible if these products demonstrate in vivo bioequivalence when compared with the reference product.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


2020 ◽  
Vol 16 (7) ◽  
pp. 867-871
Author(s):  
Harun Ergen ◽  
Muge Guleli ◽  
Cigdem Sener ◽  
Cem Caliskan ◽  
Sercan Semiz ◽  
...  

Introduction: Polyvinyl alcohol (PVA), a polymer, is in demand due to its usage in different applications such as pharmaceutical, biomedical and textile, paper, food industries. Methods: A new sensitive reversed phased high-pressure liquid chromatography (RP-HPLC) method with refractive index detector (RID) was developed for determination of PVA in an ophthalmic solution containing dexpanthenol and PVA as active substances and it was validated according to The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guideline. Results: Chromatographic separation was achieved on a Chiral-AGP (150 mm × 4.0 mm, 5 μm) column kept at 30°C with an isocratic flow at a flow rate of 1.0 ml/min. The detector temperature was 30°C, the retention time of PVA was around 1.0 min and the total run time was 5 minutes. Conclusion: The proposed method showed linearity, accuracy, precision, specificity, robustness, solution stability, and system suitability results within the acceptance criteria.


2019 ◽  
Vol 12 (3) ◽  
pp. 229-237 ◽  
Author(s):  
Alban Revy ◽  
François Hallouard ◽  
Sandrine Joyeux-Klamber ◽  
Andrea Skanjeti ◽  
Catherine Rioufol ◽  
...  

Objective: Recent gallium-68 labeled peptides are of increasing interest in PET imaging in nuclear medicine. Somakit TOC® is a radiopharmaceutical kit registered in the European Union for the preparation of [68Ga]Ga-DOTA-TOC used for the diagnosis of neuroendocrine tumors. Development of a labeling process using a synthesizer is particularly interesting for the quality and reproducibility of the final product although only manual processes are described in the Summary of Product (SmPC) of the registered product. The aim of the present study was therefore to evaluate the feasibility and value of using an automated synthesizer for the preparation of [68Ga]Ga-DOTA-TOC according to the SmPC of the Somakit TOC®. Methods: Three methods of preparation were compared; each followed the SmPC of the Somakit TOC®. Over time, overheads, and overexposure were evaluated for each method. Results: Mean±SD preparation time was 26.2±0.3 minutes for the manual method, 28±0.5 minutes for the semi-automated, and 40.3±0.2 minutes for the automated method. Overcost of the semi-automated method is 0.25€ per preparation for consumables and from 0.58€ to 0.92€ for personnel costs according to the operator (respectively, technician or pharmacist). For the automated method, overcost is 70€ for consumables and from 4.06€ to 6.44€ for personnel. For the manual method, extremity exposure was 0.425mSv for the right finger, and 0.350mSv for the left finger; for both the semi-automated and automated method extremity exposure were below the limit of quantification. Conclusion: The present study reports for the first time both the feasibility of using a [68Ga]- radiopharmaceutical kit with a synthesizer and the limits for the development of a fully automated process.


Author(s):  
B Lefrère ◽  
D Wohrer ◽  
C Godefroy ◽  
M Soichot ◽  
A Mihoubi ◽  
...  

Abstract We report the case of an 11-month-old male infant with a complex congenital heart disease who was admitted in the intensive care unit following cardiorespiratory arrest at home. Toxicological urine screening reported an ethanol concentration of 0.65 g/L using an enzymatic assay, without suspicion of alcohol intake; a significant amount of ethanol concentration was found in two plasma samples using the same enzymatic assay. Plasma and urine ethanol concentrations were below the limit of quantification (LOQ) when tested using a gas chromatography method. Urine ethanol level was also below the LOQ when tested by enzymatic assay after an initial urine ultrafiltration. These results confirmed our suspicion of matrix interference due to elevated lactate and lactate dehydrogenase levels interfering in the enzymatic assay. This analytical interference, well-known in postmortem samples, extensively studied in vitro, has been rarely reported in vivo, especially in children. To the best of our knowledge, this case is only the sixth one reported in an infant’s plasma and the first initially discovered from urine. Indeed, as for ethanol, this last matrix has not been studied in the context of this artifact that may induce false-positive ethanol results while seeking a diagnosis in life-threatening or fatal situations that are potentially subject to forensic scrutiny. In parallel to a synthetic literature review, we propose a simple, informative decision tree, in order to help health professionals suspecting a false-positive result when performing an ethanol assay.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
M. H. Sanad ◽  
A. B. Farag ◽  
S. F. A. Rizvi

Abstract This study presents development and characterization of a radiotracer, [125I]iodonefiracetam ([125I]iodoNEF). Labeling with high yield and radiochemical purity was achieved through the formation of a [125I]iodoNEF radiotracer after investigating many factors like oxidizing agent content (chloramines-T (Ch-T)), substrate amount (Nefiracetam (NEF)), pH of reaction mixture, reaction time and temperature. Nefiracetam (NEF) is known as nootropic agent, acting as N-methyl-d-aspartic acid receptor ligand (NMDA). The radiolabeled compound was stable, and exhibited the logarithm of the partition coefficient (log p) value of [125I]iodonefiracetam as 1.85 (lipophilic). Biodistribution studies in normal mice confirmed the suitability of the [125I]iodoNEF radiotracer as a novel tracer for brain imaging. High uptake of 8.61 ± 0.14 percent injected dose/g organ was observed in mice


Sign in / Sign up

Export Citation Format

Share Document