scholarly journals Faculty Opinions recommendation of High-accuracy determination of internal circadian time from a single blood sample.

Author(s):  
Felix Naef
2018 ◽  
Vol 128 (9) ◽  
pp. 3826-3839 ◽  
Author(s):  
Nicole Wittenbrink ◽  
Bharath Ananthasubramaniam ◽  
Mirjam Münch ◽  
Barbara Koller ◽  
Bert Maier ◽  
...  

2015 ◽  
Vol 5 (1) ◽  
Author(s):  
Jarosław Judek ◽  
Arkadiusz P. Gertych ◽  
Michał Świniarski ◽  
Anna Łapińska ◽  
Anna Dużyńska ◽  
...  

1965 ◽  
Vol 20 (4) ◽  
pp. 774-778 ◽  
Author(s):  
Domenic A. Maio ◽  
James R. Neville

A polarographic method was described in an earlier report which permits the accurate, rapid determination of oxygen content in small samples of blood. As with the Van Slyke technic, total oxygen capacity was formerly estimated by a separate determination of the oxygen content after complete saturation with oxygen of another portion of the blood sample. Further experience with the polarographic method has revealed the feasibility of estimating both content and capacity in a single blood sample. The capacity estimate is made possible by the polarographic observation of the quantity of potassium ferricyanide required to convert ferrohemoglobin to ferrihemoglobin. The measurement of oxygen content is performed, as previously described, by the polarographically determined increase in physically dissolved oxygen caused by the release of bound oxygen. By this means, one avoids sampling and random errors inherent in the use of two separate determinations. The method requires only a brief time for performance and ordinary technical proficiency. It is also simple in application. polarographic dropping mercury electrode; oxygen tension; digitonin; potassium ferricyanide; ferrohemoglobin; ferrihemoglobin Submitted on June 24, 1964


1972 ◽  
Vol 18 (9) ◽  
pp. 976-979 ◽  
Author(s):  
David G Geeting ◽  
Charles A Suther ◽  
Philip Sylbert

Abstract Several methods are available for determination of glucose in whole blood and serum. When comparing the results of these methods on a single blood sample, one may find significantly different values. Here, equations are provided for converting values for whole blood glucose to values for serum glucose, obtained by different methods.


2020 ◽  
Vol 873 ◽  
pp. 114358
Author(s):  
Qingpeng Cao ◽  
Bo Liang ◽  
Congcong Yu ◽  
Lu Fang ◽  
Tingting Tu ◽  
...  

1987 ◽  
Vol 65 (11) ◽  
pp. 1571-1572 ◽  
Author(s):  
Kohji Ohbayashi ◽  
Masayuki Udagawa ◽  
M. Watabe

A high-accuracy determination of the fine structures in the Raman spectrum of superfluid 4He at 1.3 K under saturated vapor pressure has been done with a multichannel monochromator. The experimental Raman structure cannot be explained by conventional theories. Comments on our recent studies of the pressure dependence of the Raman structure are given.


Sign in / Sign up

Export Citation Format

Share Document