scholarly journals Potential influence of a planned landfill on a high karst plateau in Southwestern Montenegro to nearby karstic springs

2021 ◽  
Vol 50 (2-3) ◽  
Author(s):  
Micha Horacek ◽  
Milan Radulovic ◽  
Dejan Jancic ◽  
Stefan Wyhlidal ◽  
Golub Culafic

The potential threat of a landfill projected on a high karst plateau in southwest Montenegro is investigated with respect to the subjacent nearby springs. The locality is called Duboki do. As the springs are used for drinking water supply this investigation is urgently needed. For the springs exist two hypotheses concerning their catchment area: I) from the high karst plateau, or II) from a topographically lower area. The stable H- and O-isotope ratios of water samples from the springs are compared with precipitation isotope data, to reveal the catchment area of the springs. The isotope results indicate that the catchment area of the springs is at higher altitude fitting to, and in good agreement with, winter precipitation from the high karst plateau of the planned land-fill locality.

2014 ◽  
Vol 884-885 ◽  
pp. 91-95
Author(s):  
Shang Chao Yue ◽  
Le Jun Zhao ◽  
Xiu Duo Wang ◽  
Qi Shan Wang ◽  
Feng Hua He

The objectives of this study were to investigate impact of preoxidation on disinfection by-product (DBP) precursors in drinking water via two different preoxidation methods. The full-scale study was conducted on surface river water in a water supply plant in Tianjin, China. Two treatment trains were performed, with prechlorination and preozonation as preoxidation methods, respectively. The water samples were collected on different stages along the treatment processes and analyzed by following organic parameters: dissolved organic carbon (DOC), UV254 and specific ultraviolet absorbance (SUVA). The results indicated that Train 2 with preozonation was more effective to reduce DBP precursors. Preozonation possessed an excellent ability in the removal of UV254 and SUVA, the removal efficiencies were 25.14% and 18.77%, respectively, comparing to the removal rates of 6.66% and 5.64% during prechlorination, separately.


Author(s):  
Marina Valentukeviciene ◽  
Aukse Amosenkiene ◽  
Regimantas Dauknys

Quality changes of drinking water in the water supply network (case study from Lithuania) The purpose of this research was to examine water quality changes by distributing in to the water supply network. Water samples were collected from Varena town (Lithuania) drinking water distribution system fed by groundwater from well field. Parameters related to undesirable increasing of nitrites and nitrates concentrations have been measured considering these samples: pH, conductivity, concentration of total iron, manganese, ammonium, nitrates and nitrites. Results showed that groundwater from well field were extremely susceptible to favor bacterial growth in the pipelines. The occurrence of nitrites and nitrates in drinking water samples correlated positively with the lengths of old iron pipelines and negatively with the content of newly laid pipelines. The obtained results also showed that the potential nitrates increasing induced by the distribution of treated water could be reduced if: nitrates levels were below detection limits at the outlet of the water treatment plant; biological ammonium removal treatment implementation should reduce the levels of the nitrates and nitrites of the treated supplied water. Although the nitrates concentration increase in drinking water distribution systems, the issues with nitrites accumulation are rare in Lithuania. However, such processes still need to be proved in more extensive investigation, but these research results could be applied as a basic scenario.


The essential requirement for human life to exist is water. After to the air, the other It has in various sources such as canals, ponds, rivers, lake, streams, reservoirs and etc. human settlers on the banks of major river systems at the earliest and has need water for drinking, bathing, cooking, laundering, and many more. But with the advancement of civilization the demand of water supply grately increased and now has such a stage to come that without well organized public water supply scheme, it is not possible to move the present human life and the develop the towns. Earlier has importance on quantity. And now today importance of quality comes to be recognized gradually in the later days. In this present study, numbers of water samples were collected various water supply schemes from 20 villages of bhimavaram region, West Godavari district, Andhra Pradesh. The drinking water samples are analyze its biological quality and it was found that some of the samples in the study area are exceeds or above the standard limit or permissible limit. On over all based on biological quality few drinking water sources located in and around different areas of Bhimavaram was seriously polluted by harmful bacteria and must need few treatment methods. So that need of attention not to use of supplied water and need to give suggestions and remedial measures to concerned local authorities of various disinfection treatment technologies or control measure to make supplied water free from pathogenic Bactria. Quality Assessment of drinking water from various sources (S Malhotra, S.K., Sndhu (2015), especially bacteriological quality should be periodically planned regularly to avoid and control waterborne diseases


Author(s):  
Wenjin Xue ◽  
Christopher W. K. Chow ◽  
John van Leeuwen

Abstract The bacterial regrowth potential (BRP) method was utilised to indirectly measure the assimilable organic carbon (AOC) as an indicator for the assessment of the microbial regrowth potential in drinking water distribution systems. A model using various microbial growth parameters was developed in order to standardise the experimental interpretation for BRP measurement. This study used 82 experimental BRP data sets of water samples collected from the water treatment plant to locations (customer taps) in the distribution system. The data were used to model the BRP process (growth curve) by a data fitting procedure and to obtain a best-fitted equation. Statistical assessments and model validation for evaluating the equation obtained by fitting these 82 sets of data were conducted, and the results show average R2 values were 0.987 for treated water samples (collected at the plant prior to chlorination) and 0.983 for tap water (collected at the customer taps). The F values obtained from the F-test are all exceeded their corresponding F critical values, and the results from the t-test also showed a good outcome. These results indicate this model would be successfully applied in modelling BRP in drinking water supply systems.


2011 ◽  
Vol 9 (2) ◽  
pp. 415-428 ◽  
Author(s):  
Md. Atikul Islam ◽  
Hiroyuki Sakakibara ◽  
Md. Rezaul Karim ◽  
Masahiko Sekine ◽  
Zahid Hayat Mahmud

This study was conducted to assess the bacteriological quality of alternative drinking water supply options in southwest coastal areas of Bangladesh. A total of 90 water samples were collected during both dry and wet seasons from household based rainwater harvesting systems (RWHSs), community based rain water harvesting systems (CRWHSs), pond-sand filters (PSFs) and ponds. The samples were evaluated for faecal coliform, Escherichia coli and Heterotrophic Plate Count, as well as Vibrio cholerae, Salmonella spp., Shigella spp. and Pseudomonas spp. Physico-chemical parameters (pH, electrical conductivity, and color) were also examined. In addition, sanitary inspections were conducted to identify faecal contamination sources. All options showed varying degrees of indicator bacterial contamination. The median E. coli concentrations measured for RWHSs, CRWHSs, PSFs, and ponds were 16, 7, 11, and 488 cfu/100 ml during the wet season, respectively. Vibrio cholerae O1/O139, Salmonella and Shigella spp. were not found in any samples. However, Vibrio cholerae Non-O1/Non-O139 and Pseudomonas spp. were isolated from 74.4% and 91.1% of the water samples collected during the wet season. A maximum pH of 10.4 was found in CRWHSs. Estimation of the disease burden for all options in disability adjusted life years (DALYs) showed an increased disease burden during the wet season. According to sanitary inspections, poor maintenance and unprotected ponds were responsible for rainwater and PSF water contamination, respectively. The findings of the present study suggest that alternative drinking water supply options available in southwest coastal Bangladesh pose a substantial risk to public health.


1984 ◽  
Vol 3 (5) ◽  
pp. 383-392 ◽  
Author(s):  
J.C. Sherlock ◽  
D. Ashby ◽  
H.T. Delves ◽  
G.I. Forbes ◽  
M.R. Moore ◽  
...  

1 The water supply in Ayr (Scotland, UK) was plumbosolvent and many dwellings in Ayr contained lead pipes. In 1981 treatment of the water supply to reduce its plumbosolvency was initiated. Measurements of water and blood lead concentrations were made before and subsequent to the treatment. Most of the measurements made before and after water treatment began were made on water samples from the same dwellings and blood samples from the same women. 2 Water treatment produced a sharp fall in water lead concentrations and a decrease in the median blood lead concentration from 21 to 13 μg/100 ml. 3 Two women had higher than expected blood lead concentrations, both these women had been removing old paint. 4 Women who had lead pipes removed from their dwellings all showed substantial decreases in their blood lead concentrations. 5 The curvilinearity of the relation between blood lead and water lead concentrations is confirmed. Even relatively low (<40 μg/l) water lead concentrations may make a substantial contribution to blood lead concentrations.


2015 ◽  
Vol 3 (9) ◽  
pp. 5287-5295 ◽  
Author(s):  
K. Y. Liu ◽  
L. M. Cong ◽  
Z. J. Lan ◽  
R. P. Ma ◽  
L. Yu ◽  
...  

Abstract. On 8 November 2013, super typhoon Haiyan made landfall in Philippines. On 24 November, the Chinese hospital ship arrived in Philippines to help with disaster relief efforts. Drinking water was collected at a variety of locations, and the concentration levels of lead were determined with field test kit. The results showed that the levels of lead in 67% of total collected water samples exceeded WHO's standard. Afterwards, the local government had taken many measures to ensure a safe water supply in next few months. This is the first report about water quality in Philippines after the disaster.


2021 ◽  
Vol 2 (5) ◽  
pp. 6475-6490
Author(s):  
Roberto Mena Rivero ◽  
Ricardo Enrique Vega Azamar ◽  
Flor Virginia Cruz Gutiérrez ◽  
David Gustavo Rejón Parra ◽  
Fermín Téllez Gómez

La baja disponibilidad de agua potable de buena calidad puede ser complementada con agua proveniente de la lluvia, si esta última es recolectada en cantidad suficiente para cubrir la demanda, aprovechándose esta combinación para resolver el problema de abastecimiento, todo esto sujeto a restricciones de inversión. El presente trabajo tiene por objetivo presentar un análisis de los sistemas de captación de agua de lluvia existentes en la zona limítrofe entre los estados mexicanos de Quintana Roo y Campeche para estimar los montos de inversión máxima que justifiquen un proyecto de mejora en la disponibilidad de agua de lluvia. En esta investigación se identificó el nivel de aprovechamiento y los requerimientos de los sistemas de captación de agua pluvial en techos (SCAPT) y se determinó el monto de inversión máxima para solucionar esta situación problemática. Los resultados muestran que los SCAPT no se aprovechan debido a limitaciones o subutilización en la superficie de captación y/o capacidad de almacenamiento, por lo que se recurre al suministro de agua en pipas. Se concluye que se puede sustituir el acarreo en pipas por agua de lluvia con un adecuado dimensionamiento de la superficie y el volumen de captación, asegurando el consumo de agua mínimo recomendado, con una inversión menor de la que se requeriría para la implementación de un sistema de abastecimiento de agua convencional.   Low availability of good quality drinking water can be complemented with rainwater, if the latter is collected in sufficient quantity to cover the demand, taking advantage of this combination to solve the supply problem, all of this subject to investment restrictions. The present work aims to present an analysis of the existing rainwater harvesting (RWH) systems in the border area between the Mexican states of Quintana Roo and Campeche to estimate the maximum investment amount that justifies a project to improve rainwater availability. In this research, the use level and the requirements of rooftop rainwater harvesting (RTRWH) systems were identified and the maximum investment amount needed to solve this problematic situation was determined. Results show that RTRWH systems are not used due to insufficient or underutilized catchment area and / or storage capacity, so water is supplied in tankers. It is concluded that transport in tankers can be replaced by RTRWH with an adequate dimensioning of surface and catchment volume, ensuring the minimum recommended water supply, with a lower investment than that required for the implementation of a conventional water supply system.


2021 ◽  
Vol 23 (2) ◽  
pp. 146-152
Author(s):  
Bharati Shakya ◽  
Supri Raj Shrestha ◽  
Vinutha Silvanus

Water safety and quality are fundamental to human development and well-being. Yet, at least 2 billion people are using a drinking water source contaminated with feces worldwide. This study was conducted to assess the types of water supply, storage and methods of purification of drinking water and to examine the bacteriological quality of supplied and drinking water at household level by most probable number (MPN) test in Makalbari area in Gokarneshwor Municipality, Kathmandu. A total of 80 households were selected using simple random sampling technique and two samples (one from main water supply and another from drinking water, n=160 water samples) were collected from each household. Ethical clearance was taken from the Nepal Medical College Institutional Review Committee. SPSS version 16.0 was used for statistical analysis. Majority of water supply samples 65 (81.2%) were from tap, 11 (13.8%) were from well and 4 (5.0%) samples were from bore well. Bacteriologically, of the total water supply samples, 34 (42.5%) samples were excellent, 16 (20.0%) samples were suspicious and 30 (37.5%) samples were unsatisfactory by MPN index quality. Most of the households stored drinking water in the tanks 34 (42.5%). Most of the water samples 29 (36.3%) were directly consumed from the water supply without purification. Among the directly consumed drinking water samples, 13 (44.8%) samples showed unsatisfactory MPN index. Most commonly used methods of water purification was filtration 21 (26.2%). Of the total drinking water samples, 33 (41.25%) samples were positive for total coliform. Thirty-two (40.0%) of the households reported diarrhea in past one year. A highly significant association was found between MPN index of drinking water and occurrence of diarrhea in the households. The quality of the most of the water samples from water supply and drinking water were unsatisfactory. Inspite of this, drinking water was not purified in some of the households. Moreover, few of the drinking water samples were not potable even after purification. Therefore, community should be made aware to improve quality of drinking water in households.


Author(s):  

The paper presents the results of the determination of heavy metals in drinking water samples from centralized water supply systems and wells of individual water supply of the Sverdlovsk region. It was found that the content of copper ions in the samples does not exceed its maximum permissible concentration, and the content of lead and cadmium ions in most samples is higher than the permissible norms. It is established that water samples from Nizhny Tagil and Serov are more contaminated with cadmium. The causes of drinking water pollution are discussed. It was found that the pollution of water from the centralized water supply systems with heavy metals is mainly due to the non-compliance of the operated water pipes with sanitary and hygienic requirements. Groundwater pollution is caused by the infiltration of industrial effluents containing heavy metals from storage and sedimentation tanks through soil. It is shown that numerous industrial enterprises in the Sverdlovsk region aggravate the process of pollution of surface and groundwater with heavy metals. The unsatisfactory quality of water in terms of the content of heavy metals in Sverdlovsk region is revealed. The authors dwell on the need to continue research to determine the content of other heavy metals in water and expand the geography of sampling in the region in order to assess more accurately the quality of water.


Sign in / Sign up

Export Citation Format

Share Document