scholarly journals A Case Study on Microbial Diversity Impacts of a Wastewater Treatment Plant to the Receiving River

2021 ◽  
Vol 09 (04) ◽  
pp. 206-220
Author(s):  
Hongfei Zhu ◽  
Bailian Li ◽  
Ning Ding ◽  
Zheng Hua ◽  
Xiaoxu Jiang
2001 ◽  
Vol 44 (2-3) ◽  
pp. 235-242 ◽  
Author(s):  
B. De heyder ◽  
P. Ockier ◽  
R. Jansen ◽  
R. Huiberts

Several process units at a wastewater treatment plant (WWTP) can produce a significant level of sound and thus induce sound nuisance for nearby residents. The risk for sound nuisance should be considered by making a prognosis of sound impact in an early project phase (planning, design). A prognosis requires information with respect to the sound characteristics of the different process units. This paper reports the development of empirical models for the sound power of relevant process units in the water line at Aquafin WWTPs. The used methodology for model derivation and validation allowed us to minimize the required number of measurements. Besides the methodology, the paper describes in detail the derivation and validation of the empirical model for the splashing water of screw pumps. Also the use of all the derived empirical models to determine the sound impact of a wastewater treatment plant at close distance is illustrated with a case-study.


2012 ◽  
Vol 66 (8) ◽  
pp. 1684-1690 ◽  
Author(s):  
Russell Yap ◽  
Michael Holmes ◽  
William Peirson ◽  
Michael Whittaker ◽  
Richard Stuetz ◽  
...  

Dissolved air flotation (DAF) incorporating filtration (DAFF) is used at the Bolivar wastewater treatment plant (WWTP) to polish lagoon effluent for reuse. Elevated algal populations are frequently experienced and can lead to increased coagulant requirements and process control issues. Streaming current detectors (SCDs) and a charge demand analyser (CDA) were used to monitor the full-scale plant. This was followed by an optimisation study using a pilot plant with a CDA. It was found that the normal operational charge demand range for DAF at Bolivar was between −46 and −40 μeq L−1. Decreasing the pH of coagulation reduced coagulant consumption and facilitated more sensitive CDA responses to changes in alum dose.


Water SA ◽  
2018 ◽  
Vol 44 (4 October) ◽  
Author(s):  
Tilik Tena Wondim ◽  
Bloodless Dzwairo

The challenge of selecting an appropriate wastewater treatment plant (WWTP) site is addressed in this study, using the case study of Bahir Dar City, Ethiopia. An innovative approach is proposed for selecting the WWTP site. Fifteen practically feasible alternatives were identified based on the geographical information system (GIS) based hydraulic design and considering the overall economy of the system. The three dimensions of sustainability were considered while evaluatingalternatives through incorporating economic, social, energy and environmental criteria in decision-making. The multiple attribute decision making (MADM) method was applied to prioritize the alternatives. Four scenarios representing the different perspectives of choices were used for weight elicitation. The results of the study show that the developed decisionmaking approach identified practically feasible alternatives. The framework and decision-making methodology developed in this study helped to facilitate the decision making by local government in a holistic view that incorporates environmental management in the city of Bahir Dar.


2020 ◽  
Vol 8 (6) ◽  
pp. 104535
Author(s):  
Valentina Innocenzi ◽  
Federica Cantarini ◽  
Alessia Amato ◽  
Barbara Morico ◽  
Nicolò Maria Ippolito ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document