scholarly journals Investigation of the Effects of Distributed Generation on Protection Coordination in a Power System

2021 ◽  
Vol 11 (5) ◽  
pp. 7628-7634
Author(s):  
A. Tariq ◽  
K. L. Khatri ◽  
M. I. U. Haque ◽  
M. A. Raza ◽  
S. Ahmed ◽  
...  

The rapid increase of the electrical power demand gave rise to many challenging situations for power system control engineers as the transmission lines are operating at their maximum capacity in most developing economies. To solve this, Distributed Generation (DG), i.e. the generation of electrical power in a distribution network that provides clean energy, is gaining popularity. There are several challenges the protection of distribution networks faces after DG installation, such as variations in short circuit levels, protection blinding, reverse power flow, protection coordination, change in fault impedance, recloser-fuse coordination, selectivity, unsynchronized reclosing, false tripping, etc. In this paper, an IEEE 13-Bus System Radial Distribution System is simulated using Electrical Transient Analyzer Program (ETAP), various scenarios of DG placement are considered, their impact on the protection system is analyzed, and different techniques are proposed to minimize the effect on protection coordination. The use of directional relays, current limiting reactors, and small magnitude DGs is tested and analyzed. The way this effect varies by changing the location of DG is also analyzed.

2020 ◽  
Vol 22 (1) ◽  
pp. 43-59
Author(s):  
Anudevi Samuel ◽  
Vinayak N. Shet

Abstract The rapid increase in the power demand and the capacity shortage of transmission and distribution system drives the integration of Distributed Generation (DG) units in electrical power distribution networks. The integration of DG resources with distribution network can cause significant impacts in protection due to the bidirectional flow of current, particularly the changes in magnitude and direction of short circuit currents. It may also lead to false tripping or fail to trip the over current protection relays in the power system. The relay parameters have to adapt to the changes in the system to avoid unnecessary trippings. The proposed adaptive over current protection scheme, sets the parameters of the relays according to the changes in the network. This method determines the plug multiplier settings (PMS) and the time multiplier settings (TMS) using Sugeno Fuzzy Inference System (SFIS). The proposed methodology is tested for IEEE 13 bus system and 33 bus system and with the obtained adaptive relay settings, the validation for relay coordination is done using ETAP.


2019 ◽  
Vol 2 (3) ◽  
pp. 25 ◽  
Author(s):  
Ashish Shrestha ◽  
Roshan Kattel ◽  
Manish Dachhepatic ◽  
Bijen Mali ◽  
Rajiv Thapa ◽  
...  

The issue of unintentional islanding in grid interconnection still remains a challenge in grid-connected, Distributed Generation System (DGS). This study discusses the general overview of popular islanding detection methods. Because of the various Distributed Generation (DG) types, their sizes connected to the distribution networks, and, due to the concern associated with out-of-phase reclosing, anti-islanding continues to be an issue, where no clear solution exists. The passive islanding detection technique is the simplest method to detect the islanding condition which compares the existing parameters of the system having some threshold values. This study first presents an auto-ground approach, which is based on the application of three-phase, short-circuit to the islanded distribution system just to reclose and re-energize the system. After that, the data mining-decision tree algorithm is implemented on a typical distribution system with multiple DGs. The results from both of the techniques have been accomplished and verified by determining the Non-Detection Zone (NDZ), which satisfies the IEEE standards of 2 s execution time. From the analysis, it is concluded that the decision tree approach is effective and highly accurate to detect the islanding state in DGs. These simulations in detail compare the old and new methods, clearly highlighting the progress in the field of islanding detection.


Author(s):  
Mehrnoosh Vatani

<p>Adding distributed Generators (DGs) to the passive electrical networks causes major changes in the specifications of the network including voltage profile, short circuit level and transient stability. In this paper, the effect of DGs switching transient in network is considered. The DGs location are changed in different buses. Two types of DGs are used (i.e. wind and synchronous DGs). Switching transient signals are time variant. It has a continuous spectrum of frequency. Fast Fourier and Wavelet transform methods are used for transient analysis. The proposed method is applied to IEEE-13 Bus distribution system.</p>


Author(s):  
Kamlesh Kumar ◽  
Mahesh Kumar

With increasing population and urbanization, the demand of electricity also increases day by day; to fulfill this demand, clean and environment-friendly distributed generations are being installed, but these have some issues in power section. With the integration of DG load curve is levelized, feeder voltage is improved; loading effect on the transformer and branches is reduced, and provides electricity with no pollution. This chapter investigates impacts of DGs to the power system; distributed generation means to generate electric power near the power consumption point. Power quality and reliability can be enhanced by the interconnection of distribution generation to an existing distribution system. However, there are so many effects of distributed generation e.g. changing of load losses, increasing of short circuit levels, voltage transient, congestions in the system branches, power quality, and reliability and network protection issues such as false tripping, nuisance tripping, unintentional islanding, neutral shifting is mainly affected.


Author(s):  
Sunny Katyara ◽  
Lukasz Staszewski ◽  
Faheem Akhtar Chachar

Background: Since the distribution networks are passive until Distributed Generation (DG) is not being installed into them, the stability issues occur in the distribution system after the integration of DG. Methods: In order to assure the simplicity during the calculations, many approximations have been proposed for finding the system’s parameters i.e. Voltage, active and reactive powers and load angle, more efficiently and accurately. This research presents an algorithm for finding the Norton’s equivalent model of distribution system with DG, considering from receiving end. Norton’s model of distribution system can be determined either from its complete configuration or through an algorithm using system’s voltage and current profiles. The algorithm involves the determination of derivative of apparent power against the current (dS/dIL) of the system. Results: This work also verifies the accuracy of proposed algorithm according to the relative variations in the phase angle of system’s impedance. This research also considers the varying states of distribution system due to switching in and out of DG and therefore Norton’s model needs to be updated accordingly. Conclusion: The efficacy of the proposed algorithm is verified through MATLAB simulation results under two scenarios, (i) normal condition and (ii) faulty condition. During normal condition, the stability factor near to 1 and change in dS/dIL was near to 0 while during fault condition, the stability factor was higher than 1 and the value of dS/dIL was away from 0.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2699
Author(s):  
Marceli N. Gonçalves ◽  
Marcelo M. Werneck

Optical Current Transformers (OCTs) and Optical Voltage Transformers (OVTs) are an alternative to the conventional transformers for protection and metering purposes with a much smaller footprint and weight. Their advantages were widely discussed in scientific and technical literature and commercial applications based on the well-known Faraday and Pockels effect. However, the literature is still scarce in studies evaluating the use of optical transformers for power quality purposes, an important issue of power system designed to analyze the various phenomena that cause power quality disturbances. In this paper, we constructed a temperature-independent prototype of an optical voltage transformer based on fiber Bragg grating (FBG) and piezoelectric ceramics (PZT), adequate to be used in field surveys at 13.8 kV distribution lines. The OVT was tested under several disturbances defined in IEEE standards that can occur in the electrical power system, especially short-duration voltage variations such as SAG, SWELL, and INTERRUPTION. The results demonstrated that the proposed OVT presents a dynamic response capable of satisfactorily measuring such disturbances and that it can be used as a power quality monitor for a 13.8 kV distribution system. Test on the proposed system concluded that it was capable to reproduce up to the 41st harmonic without significative distortion and impulsive surges up to 2.5 kHz. As an advantage, when compared with conventional systems to monitor power quality, the prototype can be remote-monitored, and therefore, be installed at strategic locations on distribution lines to be monitored kilometers away, without the need to be electrically powered.


Author(s):  
Damien Ernst ◽  
Mevludin Glavic ◽  
Pierre Geurts ◽  
Louis Wehenkel

In this paper we explain how to design intelligent agents able to process the information acquired from interaction with a system to learn a good control policy and show how the methodology can be applied to control some devices aimed to damp electrical power oscillations. The control problem is formalized as a discrete-time optimal control problem and the information acquired from interaction with the system is a set of samples, where each sample is composed of four elements: a state, the action taken while being in this state, the instantaneous reward observed and the successor state of the system. To process this information we consider reinforcement learning algorithms that determine an approximation of the so-called Q-function by mimicking the behavior of the value iteration algorithm. Simulations are first carried on a benchmark power system modeled with two state variables. Then we present a more complex case study on a four-machine power system where the reinforcement learning algorithm controls a Thyristor Controlled Series Capacitor (TCSC) aimed to damp power system oscillations.


Author(s):  
Adel M Sharaf ◽  
Khaled Mohamed Abo-Al-Ez

In a deregulated electric service environment, an effective electric transmission and distribution networks are vital to the competitive environment of reliable electric service. Power quality (PQ) is an item of steadily increasing concern in power transmission and distribution. The traditional approach to overcoming capacity and quality limitations in power transmission and distribution in many cases is the addition of new transmission and/or generating capacity. This, however, may not be practicable or desirable in the real case, for many of reasons. From technical, economical and environmental points of view, there are two important - and most of the time combined - alternatives for building new transmission or distribution networks to enhance the transmission system capacity, and power quality: the Flexible alternating current transmission devices and controllers, and the distributed generation resources near the load centers. The connection of distributed generation to the distribution grid may influence the stability of the power system, i.e. angle, frequency and voltage stability. It might also have an impact on the protection selectivity, and the frequency and voltage control in the system. This paper presents a low cost FACTS based Dynamic Distribution System Compensator (DDSC) scheme for voltage stabilization and power transfer and quality enhancement of the distribution feeders connected to a dispersed wind generator, using MATLAB/ SimPower System simulation tool.


Author(s):  
Jitendra Singh Bhadoriya ◽  
Atma Ram Gupta

Abstract In recent times, producing electricity with lower carbon emissions has resulted in strong clean energy incorporation into the distribution network. The technical development of weather-driven renewable distributed generation units, the global approach to reducing pollution emissions, and the potential for independent power producers to engage in distribution network planning (DNP) based on the participation in the increasing share of renewable purchasing obligation (RPO) are some of the essential reasons for including renewable-based distributed generation (RBDG) as an expansion investment. The Grid-Scale Energy Storage System (GSESS) is proposed as a promising solution in the literature to boost the energy storage accompanied by RBDG and also to increase power generation. In this respect, the technological, economic, and environmental evaluation of the expansion of RBDG concerning the RPO is formulated in the objective function. Therefore, a novel approach to modeling the composite DNP problem in the regulated power system is proposed in this paper. The goal is to increase the allocation of PVDG, WTDG, and GSESS in DNP to improve the quicker retirement of the fossil fuel-based power plant to increase total profits for the distribution network operator (DNO), and improve the voltage deviation, reduce carbon emissions over a defined planning period. The increment in RPO and decrement in the power purchase agreement will help DNO to fulfill round-the-clock supply for all classes of consumers. A recently developed new metaheuristic transient search optimization (TSO) based on electrical storage elements’ stimulation behavior is implemented to find the optimal solution for multi-objective function. The balance between the exploration and exploitation capability makes the TSO suitable for the proposed power flow problem with PVDG, WTDG, and GSESS. For this research, the IEEE-33 and IEEE-69 low and medium bus distribution networks are considered under a defined load growth for planning duration with the distinct load demand models’ aggregation. The findings of the results after comparing with well-known optimization techniques DE and PSO confirm the feasibility of the method suggested.


2020 ◽  
Author(s):  
Alexandre Bitencourt ◽  
Daniel H. N. Dias ◽  
Bruno W. França ◽  
Felipe Sass ◽  
Guilherme G. Sotelo

The increase in demand for electric power and the insertion of a distributed generation led to the rise of the short-circuit current in substations. Most of these Brazilian substations were designed decades ago, because of that their equipment may not support the new short-circuit current levels. To protect the installed equipment and avoid excessive costs replacing old devices, it is possible to install Fault Current Limiters (FCLs). This document is a report from an R&D project that evaluated FCL topologies considering real parameters in simulation from used equipment, concluding that the selected FCL topologies accomplished their technical objective. However, before implementing these topologies in the distribution system, one should consider the technical and economic feasibility of using semiconductor switching devices.


Sign in / Sign up

Export Citation Format

Share Document