In Operating Theatres (OT), the ventilation system plays an important role in controlling airborne contamination and reducing the risks of Surgical Site Infections (SSIs). The air cleanliness is really crucial in this field and different measurements are used in order to characterize the situation in terms of both airborne microbiological pollutants and particle size and concentration. Although the ventilation systems and airborne contamination are strictly linked, different air diffusion schemes (in particular, the Partial Unidirectional Airflow, P-UDAF, and the Mixing Airflow, MAF) and various design parameters are used, and there is still no consensus on real performance and optimum solutions. This study presents measurements procedures and results obtained during Inspection and Periodic Performance Testing (1228 observations) in a large sample of Italian OTs (175 OTs in 31 Italian hospitals) in their operative life (period from 2010 to 2018). The inspections were made after a cleaning procedure, both in “at-rest” conditions and “in operation” state. Inert and microbial contamination data (in air and on surfaces) are analyzed and commented according to four relevant air diffusion schemes and design classes. Related data on Recovery Time (RT) and personnel presence were picked up and are commented. The results confirm that the ventilation systems are able to maintain the targeted performance levels in the OT operative life. However, they attest that significant differences in real OT contamination control capabilities do exist and could be ascribed to various design choices and to different operation and maintenance practices. The study shows and confirms that the air diffusion scheme and the design airflow rate are critical factors. Beside large variations in measurements, the performance values, in terms of control of airborne particle and microbial contamination (in air and on surfaces), for P-UDAF systems are better than those that were assessed for the MAF air diffusion solution. The average performances do increase with increasing airflows, and the results offer a better insight on this relationship leading to some possible optimization.


2018 ◽  
Vol 17 (2) ◽  
pp. 28-38
Author(s):  
Supapit Viturat ◽  
Noppadon Kerddonfag ◽  
Benjawan Thumthanaruk ◽  
Savitri Vatanyoopaisarn

2021 ◽  
Vol 11 (5) ◽  
pp. 2359 ◽  
Author(s):  
Avram Manea ◽  
Diana Crisan ◽  
Grigore Baciut ◽  
Mihaela Baciut ◽  
Simion Bran ◽  
...  

Background: In the context of the Sars-CoV-2 pandemic that started in 2020, more attention is being paid to the air quality in medical offices. The medical, economic and social implications of this crisis are unprecedented. Dental offices, particularly, were significantly affected by this pandemic due to the high exposure of dental workers, limited availability of personal protective equipment (PPE) and serious financial problems. Methods: Four different procedures were compared regarding their effectiveness in air contamination reduction, both from a biological point of view and from a management point of view: Fogging, Ultraviolet C (UVC) lamps, UVC air circulation units and natural ventilation. A total of 56 Petri dishes were used to evaluate air contamination. Results: All four procedures offered good results but the decontamination time and overall effect varied depending on the chosen method. Fogging was the only method that managed to remove all the identifiable pathogens. Conclusions: Fogging proved to be superior from a medical point of view, while the UVC air circulation unit proved to be more efficient from a management point of view.


Sign in / Sign up

Export Citation Format

Share Document