scholarly journals Evaluation of fecal smear methods for research on Cryptosporidium spp. oocysts in the feces of dairy calves

2022 ◽  
Vol 43 (2) ◽  
pp. 585-598
Author(s):  
Ana Paula Molinari Candeias ◽  
◽  
Gabrieli Maria Huff ◽  
Adriana Fiorini Rosado ◽  
André Luis Vriesman Beninca ◽  
...  

The objective of this study is to compare the direct fecal smear (DFS) and centrifugal sedimentation (CS) methods in the detection of Cryptosporidium spp. oocysts in fecal samples of dairy calves. One hundred and fourteen fecal samples were collected from calves aged up to six months from 10 dairy farms located in Palotina and Francisco Alves, Paraná, Brazil. The microscopic analysis revealed the presence of Cryptosporidium spp. oocysts in 51.75% (59/114) of the samples in both methods. In CS, 48.25% (55/114) of the samples were positive, while in DFS slides, only 6.14% (7/114) were positive. Only 4 samples were positive exclusively in DFS. To ensure that there were no false-negative results in the microscopic analysis, the 55 samples that were negative in both DFS and CS were selected for molecular analysis using the nested PCR (nPCR). Of these 55 samples, 24% (13/55) were positive and forwarded for sequencing part of the genome, which made it possible to identify C. parvum, C. bovis and C. ryanae. Besides the characterization of the Cryptosporidium species, it was possible to identify bacteria of the genus Acinetobacter interfering directly in the analyzed samples. The microscopic analysis also revealed higher sensitivity when CS was used to make the fecal smears. However, some samples that were negative in this technique had positive PCR results. Thus, molecular analysis is indicated to confirm cases of Cryptosporidium spp. Further studies are necessary to prove the specificities of the used primers since the results obtained in nPCR were positive for the protozoan but, when genetic sequencing was performed, Acinetobacter spp. was identified.

2003 ◽  
Vol 15 (3) ◽  
pp. 268-273 ◽  
Author(s):  
Magdalena Jacobson ◽  
Stina Englund ◽  
András Ballagi-Pordány

Lawsonia intracellularis is an intracellular organism that causes proliferative enteritis in pigs. This bacterium is difficult to culture, and antemortem demonstration of the microbe is therefore often performed on fecal samples by polymerase chain reaction (PCR). Polymerase chain reaction is sensitive and specific, but inhibitory factors in feces might cause false-negative results. This article describes the construction and use of an internal standard, a mimic. The mimic is amplified by the same primers as those used for L. intracellularis DNA and thus could indicate false-negative results in clinical samples. The amplicon was clearly visible when as few as 10 mimic molecules were added per amplification reaction and when no inhibitors were present. When fecal samples were spiked with the mimic, the detection limit was 102 molecules per PCR. Sixty clinical samples, 20 from wild boars, 20 from growing pigs with diarrhea, and 20 from pigs without diarrhea, were prepared by a boiling procedure and subjected to PCR together with 103 mimic molecules. Nine samples were positive, of which 7 originated from pigs with diarrhea and 2 from pigs without diarrhea. In 14 samples from wild boars, in 8 samples from pigs without diarrhea, and in 3 samples from pigs with diarrhea, neither the mimic nor the target DNA was visible. This indicated the presence of inhibitors in these samples. It is concluded that the mimic can be used as an internal control in the diagnosis of L. intracellularis to indicate inhibition of PCR.


2011 ◽  
Vol 102 (3) ◽  
pp. 261-266 ◽  
Author(s):  
R.A. King ◽  
J.S. Davey ◽  
J.R. Bell ◽  
D.S. Read ◽  
D.A. Bohan ◽  
...  

AbstractThe molecular detection of predation is a fast growing field, allowing highly specific and sensitive detection of prey DNA within the gut contents or faeces of a predator. Like all molecular methods, this technique is prone to potential sources of error that can result in both false positive and false negative results. Here, we test the hypothesis that the use of suction samplers to collect predators from the field for later molecular analysis of predation will lead to high numbers of false positive results. We show that, contrary to previous published work, the use of suction samplers resulted in previously starved predators testing positive for aphid and collembolan DNA, either as a results of ectopic contamination or active predation in the collecting cup/bag. The contradictory evidence for false positive results, across different sampling protocols, sampling devices and different predator-prey systems, highlights the need for experimentation prior to mass field collections of predators to find techniques that minimise the risk of false positives.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Coronaviruses ◽  
2020 ◽  
Vol 01 ◽  
Author(s):  
Maria Silvia De Feo ◽  
Viviana Frantellizzi ◽  
Giuseppe De Vincentis

Background: We present the case of a 55-year-old woman, admitted to the Infectious Disease Department of Policlinico Umberto I, Rome, in mid-March 2020, with suspicion of COVID-19 infection. Objective: The rRT-PCR was negative and the following CT scan, performed to exclude false-negative results and help diagnosis, was inconclusive. Methods: It was decided to submit the patient to 99mTc-HMPAO-labelled leukocyte scan. Results: This exam led to the diagnosis of infective endocarditis. Conclusion: In the present pandemic scenario, 99mTc-HMPAO-labelled leukocyte scan represents a reliable imaging technique for differential diagnosis with COVID-19 in patients with confusing clinical signs, possible false-negative rRT-PCR results and inconclusive CT scan.


Author(s):  
Hyoung-Jin Moon ◽  
Won Lee ◽  
Ji-Soo Kim ◽  
Eun-Jung Yang ◽  
Hema Sundaram

Abstract Background Aspiration testing before filler injection is controversial. Some believe that aspiration can help prevent inadvertent intravascular injection, while others cite false-negative results and question its value given that the needle position always changes somewhat during injection procedures. Objectives To test the relation of false-negative results to the viscosity of the material within the needle lumen and determine whether a less viscous material within the needle lumen could decrease the incidence of false-negative results. Methods In vitro aspiration tests were performed using 30-G and 27-G needle gauges, two cross-linked hyaluronic acid fillers, normal saline bags pressurized at 140 and 10 mmHg to mimic human arterial and venous pressures, and three needle lumen conditions (normal saline, air, and filler). Testing was repeated three times under each study condition (72 tests in total). For in vivo correlation, aspiration tests were performed on femoral arteries and central auricular veins in three rabbits (4–5 aspirations per site, 48 tests in total). Results In vitro and in vivo testing using 30-G needles containing filler both showed false-negative results on aspiration testing. In vitro and in vivo testing using needles containing saline or air showed positive findings. Conclusions False-negative results from aspiration testing may be reduced by pre-filling the needle lumen with saline rather than a filler. The pressurized system may help overcome challenges of animal models with intravascular pressures significantly different from those of humans. The adaptability of this system to mimic various vessel pressures may facilitate physiologically relevant studies of vascular complications.


Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.


Sign in / Sign up

Export Citation Format

Share Document