scholarly journals Forced Degradation of Flibanserin Bulk Drug: Development and Validation of Stability Indicating RP-HPLC Method

2022 ◽  
Vol 56 (1) ◽  
pp. 32-42
Author(s):  
Yik-Ling Chew ◽  
Hon-Kent Lee ◽  
Mei-Ann Khor ◽  
Kai-Bin Liew ◽  
Bontha Venkata Subrahmanya Lokesh ◽  
...  
PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0244951
Author(s):  
Hany W. Darwish ◽  
Nesma A. Ali ◽  
Ibrahim A. Naguib ◽  
Mohamed R. El Ghobashy ◽  
Abdullah M. Al-Hossaini ◽  
...  

A reliable, selective and sensitive stability-indicating RP-HPLC assay was established for the quantitation of bromazepam (BMZ) and one of the degradant and stated potential impurities; 2-(2-amino-5-bromobenzoyl) pyridine (ABP). The assay was accomplished on a C18 column (250 mm × 4.6 mm i.d., 5 μm particle size), and utilizing methanol-water (70: 30, v/v) as the mobile phase, at a flow rate of 1.0 ml min-1. HPLC detection of elute was obtained by a photodiode array detector (DAD) which was set at 230 nm. ICH guidelines were adhered for validation of proposed method regarding specificity, sensitivity, precision, linearity, accuracy, system suitability and robustness. Calibration curves of BMZ and ABP were created in the range of 1–16 μg mL-1 with mean recovery percentage of 100.02 ± 1.245 and 99.74 ± 1.124, and detection limit of 0.20 μg mL-1 and 0.24 μg mL-1 respectively. BMZ stability was inspected under various ICH forced degradation conditions and it was found to be easily degraded in acidic and alkaline conditions. The results revealed the suitability of the described methodology for the quantitation of the impurity (ABP) in a BMZ pure sample. The determination of BMZ in pharmaceutical dosage forms was conducted with the described method and showed mean percentage recovery of 99.39 ± 1.401 and 98.72 ± 1.795 (n = 6), respectively. When comparing the described procedure to a reference HPLC method statistically, no significant differences between the two methods in regard to both accuracy and precision were found.


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


Sign in / Sign up