scholarly journals The Thermal Character of a 1 m Methanol Pool Fire

2021 ◽  
Author(s):  
Kunhyuk Sung ◽  
Jian Chen ◽  
Matthew Bundy ◽  
Marco Fernandez ◽  
Anthony Hamins
Keyword(s):  
2004 ◽  
Vol 12 (3) ◽  
pp. 209-222
Author(s):  
LIU JIANGHONG ◽  
FANG YUDONG ◽  
LIAO GUANGXUAN ◽  
LIN LIN

2012 ◽  
Vol 22 (2) ◽  
pp. 201-222
Author(s):  
Pramod C. Ramteke ◽  
Akhilesh Gupta ◽  
Ravi Kumar ◽  
A. K. Gupta ◽  
Pawan K. Sharma

2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


2021 ◽  
pp. 073490412110301
Author(s):  
Yawei Wang ◽  
Gaowan Zou ◽  
Conglin Liu ◽  
Y Gao

The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.


2011 ◽  
Vol 11 ◽  
pp. 550-559 ◽  
Author(s):  
Xiao Xk ◽  
Kuang Kq ◽  
Liang Ts ◽  
Tang Hd ◽  
Liao Gx ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document