bone stock
Recently Published Documents


TOTAL DOCUMENTS

169
(FIVE YEARS 44)

H-INDEX

21
(FIVE YEARS 2)

2022 ◽  
Author(s):  
Josep Torrent ◽  
Raúl Figa ◽  
Iban Clares ◽  
Eduard Rabat

Abstract Background: Recurrences of hallux valgus can be difficult to manage, especially after a prior simple bunionectomy. This study aimed to present a treatment algorithm for the correction of recurrences after a simple bunionectomy.Methods: This was a single-center, descriptive, and retrospective comparative study. Thirty-four consecutive patients were classified according to the bone stock and the presence or absence of end-stage arthritis of the first metatarsophalangeal joint (MTPJ). According to our algorithm, we only performed an osteotomy as the salvage procedure in cases with sufficient bone stock and absence of or mild arthritis. In the other cases, we performed an MTPJ fusion. Exceptionally, we chose a Keller-Brandes arthroplasty for patients with advanced age and comorbidities. Results: We performed 17 scarf osteotomies (50%), 15 MTPJ arthrodeses (44.1%), and 2 Keller-Brandes arthroplasties (5.9%). Following the algorithm, we achieved an improvement of the AOFAS score of >30 points without severe complications in all groups.Conclusions: The proposed operative algorithm successfully addresses the recurrences considering the lack of bone stock and the presence of MTPJ arthritis.Level of EvidenceLevel 3: retrospective comparative study


Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 442
Author(s):  
William Solórzano-Requejo ◽  
Carlos Ojeda ◽  
Andrés Díaz Lantada

The biomechanical performance of hip prostheses is often suboptimal, which leads to problems such as strain shielding, bone resorption and implant loosening, affecting the long-term viability of these implants for articular repair. Different studies have highlighted the interest of short stems for preserving bone stock and minimizing shielding, hence providing an alternative to conventional hip prostheses with long stems. Such short stems are especially valuable for younger patients, as they may require additional surgical interventions and replacements in the future, for which the preservation of bone stock is fundamental. Arguably, enhanced results may be achieved by combining the benefits of short stems with the possibilities of personalization, which are now empowered by a wise combination of medical images, computer-aided design and engineering resources and automated manufacturing tools. In this study, an innovative design methodology for custom-made short femoral stems is presented. The design process is enhanced through a novel app employing elliptical adjustment for the quasi-automated CAD modeling of personalized short femoral stems. The proposed methodology is validated by completely developing two personalized short femoral stems, which are evaluated by combining in silico studies (finite element method (FEM) simulations), for quantifying their biomechanical performance, and rapid prototyping, for evaluating implantability.


2021 ◽  
pp. 112070002110594
Author(s):  
Arun Kannan ◽  
Chameka Madurawe ◽  
Jim Pierrepont ◽  
Stephen McMahon

Background: The placement of uncemented acetabular components during total hip arthroplasty (THA) in Crowe II and Crowe III dysplasia can be at the anatomic or high hip centre position. Purposes: Using computerised tomography data, we simulated acetabular cup placement at the anatomic hip centre and the high hip centre positions to assess whether there is a difference between the 2 in terms of bone loss from acetabular reaming and in acetabular coverage by host bone. Methods: The study population included a consecutive cohort of 19 patients (22 hips) with Crowe II or III dysplasia. 3-dimensional models of the pelvis were created for each patient and digital templating was used to determine the anatomic and high hip centre positions. The coordinates of the digitally templated cup positions were fed into an image processing software to estimate the amount of bone reamed, the cup coverage by host bone and the elevation from tear drop. Results: The mean volume of bone reamed was greater in the high hip centre position as compared to the anatomic position (27.3 ± 11. 4 cm3 vs. 19.4 ± 12.2 cm3, p  < 0.0001). The coverage of the acetabular cup by host bone was greater in the high hip centre position (87.3 ± 5.9% vs. 68.3 ± 10%). The mean elevation in the high hip centre group was 13 mm with 3 hips having a breach of the medial wall. Conclusions: In Crowe II and III dysplasia, placement of acetabular cups at the anatomic hip centre better preserves bone stock as compared to high hip centre placement and should be preferred in young patients requiring THA.


Author(s):  
Ola Belfrage ◽  
Erik Weber ◽  
Martin Sundberg ◽  
Gunnar Flivik

Abstract Introduction Previous bone density studies have generally shown bone resorption around both cemented and uncemented total hip arthroplasty (THA) stems. This is presumed to be due to stress shielding. Short stems have been introduced partly to preserve bone in the proximal femur by a more physiological loading of the bone. The purpose of this study was to evaluate bone remodeling around a short, fully hydroxyapatite-coated titanium stem that comes in a collared and collarless version. Patients and methods A prospective cohort of 50 patients included in a study evaluating the Furlong Evolution stem has been followed for 5 years. Examination was done with dual energy X-ray absorptiometry (DXA) postoperatively, at 1, 2 and 5 years. Clinical outcome was followed with radiography and both general and hip specific outcome measures. Results The two versions of the stem behaved similarly regarding bone remodeling. After an initial decrease up to 1 year, bone mineral density (BMD) increased in all Gruen zones up to 2 years and at 5 years bone stock was still preserved compared with postoperatively (net BMD + 1.2% (95% CI − 0.4 to 2.8)). Increase in BMD occurred mainly in the greater trochanter and distally around the stem with a decrease in the calcar area. Both versions showed excellent clinical outcome up to 5 years. Conclusion This short stem seems to preserve proximal bone stock up to 5 years, exhibiting similar behaviour both with and without a collar. Trial registration number and date of registration ClinicalTrials.gov, (identifier: NCT01894854). July 10, 2013.


2021 ◽  
Vol 6 (11) ◽  
pp. 1040-1051
Author(s):  
Sheryl de Waard ◽  
Jacqueline van der Vis ◽  
Pascale A.H.T. Venema ◽  
Inger N. Sierevelt ◽  
Gino M.M.J. Kerkhoffs ◽  
...  

Total hip arthroplasty is performed more frequently in younger patients nowadays, making long-term bone stock preservation an important topic. A mechanism for late implant failure is periprosthetic bone loss, caused by stress shielding around the hip stem due to different load distribution. Short stems are designed to keep the physical loading in the proximal part of the femur to reduce stress shielding. The aim of this review is to give more insight into how short and anatomic stems behave and whether they succeed in preservation of proximal bone stock. A systematic literature search was performed to find all published studies on bone mineral density in short and anatomic hip stems. Results on periprosthetic femoral bone mineral density, measured with dual-energy X-ray absorptiometry (DEXA), were compiled and analysed per Gruen zone in percentual change. A total of 29 studies were included. In short stems, Gruen 1 showed bone loss of 5% after one year (n = 855) and 5% after two years (n = 266). Gruen 7 showed bone loss of 10% after one year and –11% after two years. In anatomic stems, Gruen 1 showed bone loss of 8% after one year (n = 731) and 11% after two years (n = 227). Gruen 7 showed bone loss of 14% after one year and 15% after two years. Short stems are capable of preserving proximal bone stock and have slightly less proximal bone loss in the first years, compared to anatomic stems. Cite this article: EFORT Open Rev 2021;6:1040-1051. DOI: 10.1302/2058-5241.6.210030


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Yuki Okutani ◽  
Hiroshi Fujita ◽  
Hideto Harada ◽  
Masanao Kataoka ◽  
Yu Shimizu ◽  
...  

Abstract Background Socket fixation with bone grafting for dysplastic hips is technically demanding, and inadequate coverage of the socket may cause poor results in patients with severely dysplastic hips. An accurate technique to form a bone graft to fit into the defect is necessary. We aim to introduce the simple method of bone grafting, “inverted reamer technique” in cemented total hip arthroplasty (cTHA). Methods After acetabular preparation with a normal acetabular reamer, the bone graft was prepared from the resected femoral head with the inverted reamer. The graft can be press-fit into the defect of the acetabulum with good compatibility through this method. Then, the bone graft was fixed with 1–3 screws and the socket was implanted with bone cement. Results The “inverted reamer technique” can easily and automatically create a well-fit graft. This method is simple and technically less demanding; it can be performed by every surgeon, including trainee and inexperienced surgeons. Conclusion This method can improve the outcome of cTHA for dysplastic hips by preserving bone stock and increasing bone coverage of the socket implanted in the anatomic position.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Jingwei Zhang ◽  
Keyu Kong ◽  
Yingjun Chi ◽  
Xiaoliang Liu ◽  
Yiming Zeng ◽  
...  

Abstract Purpose This study was aimed to explore (1) location on AP pelvic X-ray that displayed bone stock in anterosuperior acetabulum; (2) whether X-ray could provide enough evidence to evaluate whether bone stock could provide support for acetabular cup; (3) criteria to determine whether anterosuperior bone stock could provide sufficient support for cup on X-ray. Methods Our study retrospectively collected 43 patients who underwent revision THA for cup loosening from 2014 to 2019. The position of anterosuperior acetabular bone stock was compared between X-ray and CT-based 3-D reconstruction. Seventy-millimeter acetabular cup was implanted simulatively to obtain the contact line between acetabular cup and superolateral remaining bone stock. The contact line length and the angle were measured. Patients were divided into cup group and cage group, and ROC curves of both contact line length and angle were drawn. Results The superolateral part of acetabulum on X-ray could reflect the anterosuperior host bone stock of acetabulum according to the comparison of anteroposterior pelvic X-ray and 3-D reconstruction. Critical point was chosen when we got the highest sensitivity with a 100% specificity in ROC curves. The critical values of contact length and angle were 15.58 mm and 25.5°. Conclusions Surgeons could assess the anterosuperior bone stock of acetabulum by AP pelvic X-ray to decide whether revision could be done merely using cup or need customized cage. Clinically, when contact line length was larger than 16 mm or contact angle was larger than 25.5°, adoption of cup could obtain primary stability in the revision surgery in most cases.


2021 ◽  
Vol 11 (8) ◽  
Author(s):  
Aurélien Traverso ◽  
Katharina Johanna Friedrich ◽  
Winfried Reichert ◽  
Stefan Bauer

Background: About 20–25% of all rotator cuff tears are associated with footprint bone cysts. Large cysts (>10 mm2) are rare but can be problematic for anchor fixation and rotator cuff repair. So far treatment of footprint bone cysts was described using large or several anchors, cement, or compaction grafting mostly with allograft bone being biologically inferior to restore bone stock compared to autologous grafts. Methods/Results: We report about a 57-year-old manual laborer with persistent pain and loss of shoulder function (subjective shoulder value [SSV] 50%). Magnetic resonance imaging showed a high-grade partial supraspinatus tendon tear (>50%) associated with a large supraspinatus footprint bone cyst (10 mm × 11 mm × 17 mm). An efficient setup in lateral position for arthroscopic autologous press-fit grafting from the iliac crest is described for single-stage arthroscopic rotator cuff repair. Improved fixation was achieved using a buddy anchor interference-fit technique. Conclusion: The clinical follow-up after 12 months showed an excellent outcome (SSV >90%, DASH-Score 14 points, and Constant-Score 87 points) with dynamic ultrasound and radiographs confirming tendon and bone stock restoration. Keywords: Footprint bone cyst, arthroscopic filling, iliac crest autologous grafting, anchor, rotator cuff repair.


Author(s):  
Rafael Loucas ◽  
Philipp Kriechling ◽  
Marios Loucas ◽  
Rany El Nashar ◽  
Christian Gerber ◽  
...  

Abstract Background Primarily posterior bone deficient (dysplastic) (Walch type C) or secondarily eroded (Walch type B2 or B3) glenoids represent a surgical challenge for shoulder arthroplasty. Due to the posteriorly static decentered head, reverse total shoulder arthroplasty (RTSA) is often considered as the treatment of choice. The purpose of this study is to report the clinical and radiographic outcomes, complications and reoperations of RTSA for posteriorly deficient glenoids. Materials and methods All patients who underwent RTSA for osteoarthritis secondary to underlying glenoid deficiency (Walch type B2, B3 and C) between 2005 and 2018 (study group), were identified from our institutional shoulder arthroplasty database and gender- and age-matched to a cohort of patients with normal glenoid bone stock (control group). Longitudinal pre- and postoperative clinical [Constant–Murley (CS) score, Subjective Shoulder Value (SSV)] and radiographic outcomes were assessed. Results We included 188 patients (94 in each group). The median follow-up was 43 ± 26 (24–144) months in the study group and 59 ± 32 (24–124) months in the control group. The glenoid deficiency was addressed by using glenoid bone reconstruction. The surgical site complication and revision rate of RTSA in patients with bony deficient glenoids were 17% and 7%. Although glenoid loosening was slightly higher in the study group (5 vs. 2), overall no significant differences were found between the study and control groups in satisfaction scores, preoperative and postoperative absolute and relative Constant scores, complication and revision rates, respectively. Conclusion Reverse total shoulder arthroplasty (RTSA) seems to be a valuable treatment option for patients with primary (dysplasia) or secondary (wear) posterior glenoid deficiency. Although severe glenoid bone loss seems to be a risk factor for glenoid component failure, the overall complication and revision rates as well as clinical and radiographic outcome are comparable to RTSA in patients without compromised glenoid bone stock. Level of evidence Level III: case–control study


2021 ◽  
Vol 87 (1) ◽  
pp. 17-23
Author(s):  
Georges Vles ◽  
Luke Simmonds ◽  
Mark Roussot ◽  
Andrea Volpin ◽  
Fares Haddad ◽  
...  

The success of conversion Total Hip Arthroplasty (THA) among primary THA and revision THA re- mains unclear. We hypothesized that most conversion THAss can be performed using primary implants and will have an uncomplicated post-operative course. Thirty-six patients (23 females, mean age 68,0y) who underwent conversion THA for failed interventions for proximal femur fractures in the period 2006-2018 were matched sequentially against patients of the same sex and age who underwent primary THA or revision THA. Data was collected on implants used, major complications, and mortality. PROMs used included the Western Ontario and McMaster Osteoarthritis Index, Harris Hip Score, Visual Analogue Scale and the EQ-5D Health Questionnaire. Seventy- two percent of patients who underwent conversion THA were treated with primary implants and never suffered from a major complication. PROMs were excellent for this group of patients. The distinction primary / conversion / revision THA could not explain differences in outcomes, however the necessity of using revision implants and the development of major complications could. The majority of conversion total hip arthroplasties can be considered a primary replacement. Predicting outcomes for THA should focus on patient frailty and technical difficulties dealing with infection, stability and loss of bone stock and should discard the conversion versus revision terminology.


Sign in / Sign up

Export Citation Format

Share Document