recurrent prostate cancer
Recently Published Documents


TOTAL DOCUMENTS

1232
(FIVE YEARS 369)

H-INDEX

66
(FIVE YEARS 10)

Cancers ◽  
2022 ◽  
Vol 14 (2) ◽  
pp. 334
Author(s):  
Paola Mapelli ◽  
Samuele Ghezzo ◽  
Ana Maria Samanes Gajate ◽  
Erik Preza ◽  
Anna Palmisano ◽  
...  

The aim of the present study is to investigate and compare the performances of 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI in identifying recurrent prostate cancer (PCa) after primary treatment and to explore the association of dual-tracer PET findings with clinical and histopathological characteristics. Thirty-five patients with biochemical relapse (BCR) of PCa underwent 68Ga PSMA PET/MRI for restaging purpose, with 31/35 also undergoing 68Ga-DOTA-RM2 PET/MRI scan within 16 days (mean: 3 days, range: 2–16 days). Qualitative and quantitative image analysis has been performed by comparing 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI findings both on a patient and lesion basis. Clinical and instrumental follow-up was used to validate PET findings. Fisher’s exact test and Mann-Whitney U test were used to investigate the association between dual-tracer PET findings, clinical and histopathological data. p-value significance was defined below the 0.05 level. Patients’ mean age was 70 years (range: 49–84) and mean PSA at time of PET/MR scans was 1.88 ng/mL (range: 0.21–14.4). A higher detection rate was observed for 68Ga-PSMA PET/MRI, with more lesions being detected compared to 68Ga-DOTA-RM2 PET/MRI (26/35 patients, 95 lesions vs. 15/31 patients, 41 lesions; p = 0.016 and 0.002). 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI findings were discordant in 11/31 patients; among these, 10 were 68Ga-PSMA positive (9/10 confirmed as true positive and 1/10 as false positive by follow-up examination). Patients with higher levels of PSA and shorter PSA doubling time (DT) presented more lesions on 68Ga-PSMA PET/MRI (p = 0.006 and 0.044), while no association was found between PET findings and Gleason score. 68Ga-PSMA has a higher detection rate than 68Ga-DOTA-RM2 in detecting PCa recurrence. The number of 68Ga-PSMA PET positive lesions is associated with higher levels of PSA and shorter PSA DT, thus representing potential prognostic factors.


2022 ◽  
Vol 15 (1) ◽  
pp. 101293
Author(s):  
Heying Duan ◽  
Lucia Baratto ◽  
Negin Hatami ◽  
Tie Liang ◽  
Carina Mari Aparici ◽  
...  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
David R. Cardoza-Ochoa ◽  
Cesar Cristancho-Rojas ◽  
David J. Pérez ◽  
Paola Moreno-Izaguirre ◽  
Melissa Guzman ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Matteo Ferrari ◽  
Giorgio Treglia

Background. Prostate-specific membrane antigen- (PSMA-) targeted agents labeled with fluorine-18 (18F) have recently become available to evaluate patients with biochemical recurrent prostate cancer (BRPCa) by using positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI). We performed a systematic review and meta-analysis about the detection rate (DR) of 18F-PSMA-1007 PET/CT or PET/MRI in BRPCa patients. Methods. A comprehensive computer literature search of PubMed/MEDLINE, EMBASE, and Cochrane Library databases for studies published through 17 May 2021 was carried out using the following search algorithm: “PSMA” AND “1007”. Only studies providing data on the DR of 18F-PSMA-1007 PET/CT or PET/MRI in BRPCa were included. A random-effects model was used to calculate the pooled DR on a per scan basis. Results. Fifteen articles (853 patients) were selected and included in the systematic review, and ten were included in the quantitative analysis. Most of the studies reported a good DR of 18F-PSMA-1007 PET/CT or PET/MRI in BRPCa including also patients with low prostate-specific membrane antigen (PSA) values. The DR of 18F-PSMA-1007 PET/CT or PET/MRI was dependent on PSA serum values. The pooled DR was 81.3% (95% confidence interval: 74.6–88%) with statistical heterogeneity. A significant reporting bias (publication bias) was not detected. Conclusions. 18F-PSMA-1007 PET/CT or PET/MRI showed a good DR in BRPCa patients in line with other PSMA-targeted agents. The DR of 18F-PSMA-1007 PET/CT or PET/MRI is influenced by serum PSA values. These findings should be confirmed by prospective multicentric trials.


2021 ◽  
Vol 1 (31) ◽  
pp. 31-33
Author(s):  
E. Ya. Mozerova ◽  
R. Yu. Karabut ◽  
A. A. Lozhkov ◽  
A. Yu. Maksimovskaya ◽  
Zh. E. Sabelnikova ◽  
...  

The aim of the study. To evaluate the results of radiation therapy for recurrent prostate cancer after radical prostatectomy.Methods. The analysis of medical records data of 60 patients with recurrent prostate cancer after radical prostatectomy (RP) was performed.Results. Biochemical control was achieved in 55 (92.0%) patients, PSA progression – in 3 (5.0%) and generalization – in 2 (3.0%) patients. Grade I–II cystitis developed in 25 patients (42.0%), grade I–II rectitis – in 7 (11.0%), late hemorrhagic cystitis was noted in 4 (7.0%) patients, late hemorrhagic rectitis – in 2 (3.3%) ones.Сonclusions. Salvage radiation therapy for recurrent prostate cancer after radical prostatectomy is an important treatment method that allows to achieve biochemical control with acceptable toxicity.


The Prostate ◽  
2021 ◽  
Author(s):  
Felix Preisser ◽  
Christoph Würnschimmel ◽  
Randi M. Pose ◽  
Alexander Heinze ◽  
Thomas Steuber ◽  
...  

Author(s):  
Ian Alberts ◽  
Clemens Mingels ◽  
Helle D. Zacho ◽  
Sabine Lanz ◽  
Heiko Schöder ◽  
...  

Abstract Purpose Amongst others, [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 are available for the detection of recurrent prostate cancer (rPC). There are currently limited data comparing the performance of these two radioligands with respect to clinical outcomes or their cost efficacy, which this study aims to address. Methods Two hundred and forty-four patients undergoing PSMA PET/CT for rPC were retrospectively analysed for this study (one hundred and twenty two with each radiopharmaceutical) to generate rates of PET positivity, negativity and unclear findings. Patients underwent follow-up to determine the rate of additional examinations and to confirm PET findings. A Markov chain decision analysis was implemented to model clinical decision-making processes and to analyse clinical performance of the two tracers. We determine their clinical cost efficacies using cost data from several countries where both radiotracers are in routine use. Results The PET positivity rate was non-significantly higher for [18F]PSMA-1007 compared to [68Ga]Ga-PSMA-11 (91.8% vs. 86.9%, p = 0.68), whereas the rate of uncertain findings was significantly greater (17.2% vs. 8.25%, p = 0.02). The probability of a true positive finding was higher for [68Ga]Ga-PSMA-11 (0.90, 95% CI 0.70-0.98) vs. [18F]PSMA-1007 (0.81, 95% CI 0.66–0.91). A significantly (p < 0.0001) higher PPV for [68Ga]Ga-PSMA-11 (0.99, 95% CI 0.99–1.0 vs. 0.86) was found compared to [18F]PSMA-1007 (0.86, 95% CI 0.82–1.00). Intervention efficacy analysis favoured [68Ga]Ga-PSMA-11, where the number needed to image (to achieve a true positive finding) was 10.58 and the number needed to image to harm (to achieve a false positive finding) was − 8.08. A cost efficacy analysis favours [68Ga]Ga-PSMA-11 in three of the four jurisdictions analysed where health economic data was available (Switzerland, Israel, Australia) and [18F]PSMA-1007 in one jurisdiction (Denmark). Conclusion The analysis reveals a non-significantly higher PET positivity rate for [18F]PSMA-1007, but finds significantly greater rates of uncertain findings and false positive findings when compared to [68Ga]Ga-PSMA-11. We find differences in the two tracers in terms of clinical performance and cost efficacy. The method presented herein is generalisable and can be used with clinical or cost data for other countries or tracers.


Sign in / Sign up

Export Citation Format

Share Document